User manual
Release 1.24
This document is subject to modification without notice
Please, if necessary, ask for new release at : contact@flashelek.com
© FLASHELEK 2007 : 17 rue Marcel Sembat F-21000 DIJON

Advertisement

Table of Contents
loading

Summary of Contents for FLASHELEK JX 5600

  • Page 1 FLASH ELEK JX 5600 User manual Release 1.24 This document is subject to modification without notice Please, if necessary, ask for new release at : contact@flashelek.com © FLASHELEK 2007 : 17 rue Marcel Sembat F-21000 DIJON...
  • Page 2: Table Of Contents

    4.1.2.3 Error trapping............................. 12 4.2 Human level ..............................13 4.3 Web site................................14 4.3.1 Index page............................... 14 4.3.2 Maintenance of the JX 5600 ........................ 15 4.3.3 Maintenance of the SFLS Clock Cards....................16 4.4 JX5600Mgr..............................17 4.5 Recovering factory configuration......................20 4.5.1 Using reset button ..........................
  • Page 3: Generals

    1 Generals The JX 5600 set has to be used in conjonction either with JX 2360 or JX 2600 families Flash Light Power Sets. Physical wiring It is used to monitor and remote control a SFLS assembly such as described underneath : The Power Station supplies the sets with main 240V AC +/- 10 % (Black wire on diagram).
  • Page 4 SFLS period of the whole SFLS. It has to be set in factory Power Station JX 5600 These 2 flashes are REILS. They have no intervall delay and, by the fact, flash always together as one.
  • Page 5 It is necessary to connect a J-Bus Load on each “end of line” to insure a perfect impedance for the digital signal. 3 J-Bus Loads are delivered with eachJX 5600 If you need spare parts do not hesitate to ask your reseller or contact@flashelek.com 5 / 22...
  • Page 6 (symetrical amplifier) may be necessary when the line is longer than 1 000 m, even if a 1 600 m trial succeded. The J-Bus lets the JX 5600 command the flash sets state and query sets infos. It is also possible to command the set via analog way. (see JX2360 Connection manual for details) JX 5600 Rear panel connector (Analog connections).
  • Page 7: Commanding The Flash Sets

    • Change the inter flash intervall delay from 0, 14, 66 or 266 ms. Querying the Flash sets The JX 5600 may query the sets for: • The present brightness set up • Wether a lamp operates or not (curative maintenance) •...
  • Page 8: Dialog With Jx 5600

    3 Harware local mode On the frontpanel, switching the “local” position configure the JX 5600 in local ode. In this mode, only the switches of the front panel command the SFLS ON/OFF switches On or Off the SFLS, as Brigthness level switches on Low, Medium or Hight intensity (LI, MI or HI).
  • Page 9: Ethernet Mode

    ASCII mode In this mode, it acts as a slave and answers to the commands and queries in ASCII mode as described below. The JX 5600 uses port 5556 and UDP protocol. Each message ends with a semicolon. Query Answer ACTIVE_MESSAGE;...
  • Page 10 Command Action STEP_CONTROLXY; This command changes the brightness level of the whole SFLS following XY value : XY = 00 to switch Off the SFLS 01 to switch On on LI mode 02 to switch On on MI mode 03 to switch On on HI mode SPEED_CONTROLXY;...
  • Page 11: Modbus-Jbus Mode

    4.1.2 ModBus-Jbus mode In this mode, it acts as a slave and answers to the commands and queries in binary following the Modbus standard, as described below. The JX 5600 uses port 502 and TCP protocol. Variable Table Register 0x00...
  • Page 12: Answer From The Jx5600

    Writing many registers : code 0x10 10 00 cc 00 ee dd xx xx xx xx…. • 00 cc is the first register number to be written • 00 ee the number of registers to be written • dd the number of bytes to be written •...
  • Page 13: Human Level

    Host name JX5600 The host name is used on title for the web pages, as it is a mean to know which JX 5600 is answering, on a situation where there are many. For example, naming a JX 5600 “25L” will let the title of the pages become :...
  • Page 14: Web Site

    Web site 4.3.1 Index page This is the default page On this page you can see that : The SFLS is on (On/Off button caption is “SFLS OFF”, the On/Off led is green, the Flashes are Yellow) The brightness level is switched on LI level (LI led is green, other are red) The SFLS has 22 flashes The flashes number 21 and 22 are configured in REILS mode The Flash number 2 is defective.
  • Page 15: Maintenance Of The Jx 5600

    4.3.2 Maintenance of the JX 5600 This page is usefull to install the JX 5600 the first time, and when, for any reason, a clock panel is changed in a Flash Box of the SFLS. The reason why is that each Flash Box has its own adress on the J-Bus line, allowing JX 5600 to communicate with it.
  • Page 16: Maintenance Of The Sfls Clock Cards

    4.3.3 Maintenance of the SFLS Clock Cards This page is mainly used for high level technical maintenance. You can use it for preventive flash lamp maintenance on checking how many times a lamp has flashed. To do it, select a lamp by clicking on its button (left column in the table). Then the selected card (nbr. 6 on the picture) will become the one you have chosen and the flash counter will appear.
  • Page 17: Jx5600Mgr

    JX5600Mgr Lauch JX5600Mgr In the menu File/Open Choose or type the IP adress of the JX5600 on which you want to connect The following window appears. 4 frames are present : • Boxes shows the state of each box • Configuration : parameter the SFLS •...
  • Page 18 Configuration frame Maintenance frame 18 / 22...
  • Page 19 Broadcast frame 19 / 22...
  • Page 20: Recovering Factory Configuration

    Recovering factory configuration If lost, you can reset the configuration by using a RS232 cable (plugged at the rear of the box). To do it, two method can be used : 4.5.1 Using reset button Unplug the mains Let pushed the red button located on rear panel, and plug again the mains, during 4 seconds After at least 4 seconds, the default parameters (Factory settings ) are restored.
  • Page 21: Entering Parameters

    4.5.2 Entering parameters • Unplug the mains • Plug the cable • Launch hyper terminal on your PC (19 200 Bauds, 8 bits, No parity, Stop) • Plug back the mains • If the JX5600 is under DHCP mode, hyper terminal shows : ...D ...D •...
  • Page 22 • Choose menu 3 and type the desired IP adress, then menu 4 and 5 and type the gateway adress and subnet mask., followed by ENTER • Choose between menu 6 and 7 according to your need of DHCP. • Then choose menu 0 Factory settings are : Serial number Be Carefull, the MAC adress is made with the serial number...