SAFETY INSTRUCTIONS

1.Make sure your battery has enough voltage
recognize the battery type before first installation.
2.The battery cable should be as short as possible to minimize loss.
3.The regulator is only suitable for lead acid batteries: OPEN,AGM, GEL
it is not suited for nickel metal hydride, lithium ions or other batteries.
4.The charge regulator is only suitable for regulating solar modules.
Never connect another charging source to the charge regulator.

PRODUCT FEATURES

1.Build-in industrial micro controller.
2.Big LCD display,all adjustable parameter.
3.Fully 4-stage PWM charge management.
4.Build-in short-circuit protection,open-circuit protection,reverse
protection,over-load protection.
5.Dual mosfet Reverse current protection ,low heat production.

LCD DISPLAY/KEY

MENU:switch between different display,or to enter/exit setting by long press.
UP:
press to increase value.
DOWN:presss to decrease value.

SYSTEM CONNECTION

1.Connect the battery to the charge regulator - plus and minus.
2.Connect the photovoltaic module to the regulator - plus and minus.
3. Connect the consumer to the charge regulator - plus and minus.
The reverse order applies when deinstalling!
An improper sequence order can damage the controller!
for the controller to
main display
MENU
UP
DOWN/ON/
OFF
battery type
work mode
Attn:
1.press the [Down] button to ON/OFF load manully at main display.
2.the work mode is working as below:

DISPLAY/SEETING

Browsing
interface
float voltage
Press MENU to browse
different interface.
Set parameter
In interface2-5,long
press MENU to enter
discharge reconnect
setting,and using[UP]
[DOWN] to set the
parameter,long press
MENU again to exit.
Long press [DOWN] to
restore parameter.
discharge stop
[24H]
load output 24hours
[1-23H]
load on after sunset and closed after setting hours
[0H]
Dusk to dawn

TROUBLE SHOOTING

Situation
Probable cause
Charge icon not on
Solar panel opened
when sunny
or reversed
Load icon off
Mode setting wrong
Battery low
Load icon slow flashing
Over load
Load icon slow flashing
Short circuit protection
Power off
Battery too low/reverse

TECHNICAL PARAMETER

MODEL
KLD1210
KLD1220
Batt voltage
12V/24V auto
Charge current
10A
20A
Discharge current
10A
20A
Max Solar input
<50V
B01 sealed
B02 Gel
Equalization
14.4V
14.2V
Float charge
13.7V(defaul,adjustable)
Discharge stop
10.7V(defaul,adjustable)
Discharge reconnect
12.6V(defaul,adjustable)
USB output
5V/3A
Self-consume
<10mA
Operating temperature
-35~+60 ℃
Size/Weight
150*78*35mm /150g
*all red color voltage X2 ,X4 while using 24V /48V system.
*Product specifications are subject to change without prior notice.
Solution
Reconnect
Set again
recharge
Reduce load watt
Auto reconnect
Check battery/connection
KLD1230
KLD4820
KLD4830
48V
30A
20A
30A
30A
20A
30A
<80V
B03 flood
14.6V

Advertisement