3. Counter current value (code: CNT)
(1) Counter current value setting
This command sets the counter current value of the file selected by the file number command (FNO).
Note that the counter value set is saved even turning OFF the power supply of he laser marker.
STX
CNT
As for the response data, either normal reception response data or abnormal reception response data is
returned.
Refer to "Response Data" (P.174) for details of both normal reception response data and abnormal reception
response data.
(2) Counter current value readout
This command reads out the selected counter current value.
STX
CNT
As for the response data, either normal reception response data or abnormal reception response data is
returned.
Refer to "Response Data" (P.174) for details of the abnormal reception response data.
Readout response data
STX
CNT
Description of data
Data
Name
length
Current value
•
CNT command is available after the file No. changing command (FNO) is set by RS-232C.
CHECK
4. Counter reset (code: CTR)
(1) Counter reset
This command sets the counter of the file selected by the file number change command (FNO) to the initial
value.
STX
CTR
As for the response data, either normal reception response data or abnormal reception response data is
returned.
Refer to "Response Data" (P.174) for details of both normal reception the abnormal reception response
data.
•
CTR command is available after the file No. changing command (FNO) is set by RS-232C.
CHECK
N
[Counter current value] (8 Bytes)
R
(Check sum)
N
[Counter current value] (8 Bytes)
Current value of the counter. No negative
8
value is existed.
S
(Check sum)
(Check sum)
Delimiter
(Check sum)
Outline
Delimiter
Delimiter
Delimiter
Content
"00000000" to "99999999"
183