Summary of Contents for Y?lmaz So?utma COOL-US CU-935A
Page 1
User's Manual – COOL-US Professional Anemometer Please read this user's manual thoroughly before using this unit and keep it properly for your future reference.
Safety Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. ◆ Environment conditions: RH≤90%(Non-Condensation) Operating Temperature: -10℃ ~ 60℃ ◆...
2. General Description The Anemometer is designed for measuring air velocity, air flow and temperature. Super large easy-reading backlit LCD displays air velocity, temperature and air velocity level at the same time. Use the strict tested meter only as specified in this manual. 3.Features Circuit: based on fast and high accurate MCU design High accuracy NTC resistance for air temperature measuring...
4.Specifications -30℃~60℃(-22℉~140℉) 0.4~30 m/s 0.8~58.3 Knots Air Velocity Range 0.9~67 MPH 78.7~5905 ft/min 1.4~108 Km/h Air Temp. Accuracy ±1.5℃(±2.7℉) Air Velocity. Accuracy ±3%±0.1 Resolution Sampling rate 1 time per second Operating temperature -20℃~60℃(-4℉~140℉) Operating humidity <90%RH(Non-condensation) Storage temperature -30℃~60℃(-22℉~140℉) Storage humidity <80%RH Air velocity level indication level 0-16 with analog bar-graph...
Page 7
Auto power off Automatically power off after approx. 15 minutes of inactivity Display 4 digits LCD display Battery life at least 30 hours Dimension(L*W*H) 158*62*32mm Weight 292g...
7. Operating Instructions Open battery cover and install a 9-volt battery in the battery compartment. Power ON:Turn the meter on by pressing " " button for 1 second until the LCD is lighted, then release the button. Power OFF : Turn the meter off by pressing and holding "...
Page 11
button again to exit HOLD mode. (9) MAX/MIN: Press " " button one time until "MAX" icon appears on the LCD to view the current MAX reading; press the button again, "MIN" icon will appear to view the current MIN reading. To exit the MAX/MIN mode, press the "...
Page 12
: Set the area units as square centimeter (fig. as above) Press“ ”to increase the data,press“ ”to decrease the date Set the area units as square meter (fig. as above) Press“ ”to increase the data,press“ ”to decrease the date...
Page 13
Set the area units as square feet (fig. as above) Press“ ”to increase the data,press“ ”to decrease the date ”to times increase the data , press“ Press“ ”to times decrease the data Air volume Air volume display x 100 the actual volume=displayed data *100...
8. Notes This meter has already been calibrated before delivery. Do not revise the calibration parameters without professional personnel and device. The recommended calibration period is one year. Repairs or servicing not covered in this manual should only be performed by qualified personnel. Do not use it in the area with high temperature of humidity.