Sentry AutoVREL Installation, Operation And Maintenance Manual page 11

Flow controller sample conditioning automation
Table of Contents

Advertisement

Tighten set screw on flat of VREL shaft
VREL Gear
AutoVREL
Control Unit
6.
Open the AutoVREL flow controller packaging and remove the front shaft adapter, set
screw and lock nut. Place the shaft adapter on the VREL control valve shaft so that the
height from the panel to the top of the adapter is approximately 3.5 inches.
7.
Place Loctite on the set screw and tighten the set screw MAKING SURE IT MAKES
CONTACT WITH THE FLAT OF THE VREL SHAFT, and tighten.
8.
Apply Loctite on the set screw shaft and tighten the set screw using the 1/8-inch
Allen wrench.
Ensuring the lock nut is tight is critical to the operation of the Sentry AutoVREL flow controller .
9.
Place and tighten the lock nut using the 7/16-inch wrench.
10. Using the 9/64-inch Allen wrench, remove the control unit and disconnect the
electrical connectors; place the control unit aside.
11. Slide the drive unit over the Sentry VREL control valve shaft. To engage the shaft
adapter with the hex drive shaft, rotate the VREL gear by hand until the AutoVREL
flow controller is seated against the panel.
12. While holding the drive unit flush against the front of the panel, place the included
nuts and washers over the four (4) threaded studs behind the panel and tighten the
AutoVREL control valve to the panel using the 1/2-inch wrench. This operation may
require two people.
Sentry AutoVREL Flow Controller
(shipped w/ shaft adapter)
Set Screw Lock Nut
(shipped w/ shaft adapter)
Shaft, w/ hex drive
Cotter Pin Hole
Cotter Pin
(to retain gear)
Screw
(2X)
#8-32 X 1.75
AutoVREL Drive Unit
Cable Way
VREL flow controller
Shaft Adapter
(shipped loose)
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents