Download Print this page

Baldor DODGE Torque-Arm TXT12 Instruction Manual page 3

Speed reducers taper bushed

Advertisement

Table 2 – Lubrication Recommendations - ISO Grades *
ISO Grades For Ambient Temperatures of 15˚ F to 60˚ F
Output
RPM
TXT12
301 – 400
150
201 – 300
150
151 – 200
150
126 – 150
150
101 – 125
150
81 – 100
150
41 – 80
150
11 – 40
150
1 – 10
220
ISO Grades For Ambient Temperatures of 50˚ F to 125˚ F
Output
RPM
TXT12
301 – 400
220
201 – 300
220
151 – 200
220
126 – 150
220
101 – 125
220
81 – 100
220
41 – 80
220
11 – 40
220
1 – 10
320
NOTES:
Below – 23ºF call application engineering.
20ºF to -22ºF use Mobil SHC 627.
Above 125ºF use Mobil SHC 634.
Torque-Arm Reducer Size
TDT13
TDT14
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
220
220
Torque-Arm Reducer Size
TDT13
TDT14
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
320
320
GUIDELINES FOR TORQUE-ARM REDUCER
During periods of long storage, or when waiting for delivery or
TDT15
installation of other equipment, special care should be taken to
150
protect a gear reducer to have it ready to be in the best condition
150
when placed into service.
150
150
By taking special precautions, problems such as seal leakage
and reducer failure due to lack of lubrication, improper
150
lubrication quantity, or contamination can be avoided. The
150
following precautions will protect gear reducers during periods
150
of extended storage:
150
220
Preparation:
1.
Drain oil from the unit. Add a vapor phase corrosion inhibiting
oil (VCI-105 oil by Daubert Chemical Co.) in accordance with
Table 3.
TDT15
2.
Seal the unit airtight. Replace the vent plug with a standard
220
pipe plug and wire the vent to the unit.
3.
Cover all unpainted exterior parts with a waxy rust
220
preventative compound that will keep oxygen away from
220
the bare metal. (Non-Rust X-110 by Daubert Chemical Co.
220
or equivalent).
220
4.
The instruction manuals and lubrication tags are paper and
must be kept dry. Either remove these documents and store
220
them inside, or cover the unit with a durable waterproof
220
cover which can keep moisture away.
220
5.
Protect reducer from dust, moisture, and other contaminants
320
by storing the unit in a dry area.
6.
In damp environments, the reducer should be packed inside
a moisture-proof container or an envelope of polyethylene
containing a desiccant material. If the reducer is to be stored
outdoors, cover the entire exterior with a rust preventative.
When placing the reducer into service:
1.
Assemble the vent plug into the proper hole.
2.
Clean the shaft extensions with petroleum solvents.
3.
Fill the unit to the proper oil level using a recommended
lubricant. The VCI oil will not affect the new lubricant.
Follow the installation instructions provided in this manual.
Reducer Size
TDT14 and TDT15
VCI #105 and #10 are interchangeable.
VCI #105 is more readily available.
3
LONG-TERM STORAGE
Table 3 - Quantities of VCI #105 Oil
TXT12
TDT13
Quarts or Liters
2.5
3.0
4.0

Advertisement

loading

This manual is also suitable for:

Dodge torque-arm tdt14Dodge torque-arm tdt13Dodge torque-arm tdt15