V0116 INDEX INDEX ................................2 CONDITIONS OF GUARANTEE ......................3 SPECIFICATIONS ..........................4 III. OVERVIEW ............................. 5 USING THE MACHINE ......................... 6 SAFETY ..............................6 INSTALLATION ............................8 Mounting arm assembly left ..........................8 Mounting arm assembly right ..........................9 Mounting the support bar ..........................
V0116 I. CONDITIONS OF GUARANTEE • The guarantee period starts the day of putting the equipment into service at the user’s place, materialized by the return of the guarantee bill for a duration of two years, 8h per day meaning about 3000 hours. •...
Non contractual document: according to the technical progress, we reserve the right to modify the characteristics of our products. Some of these characteristics are recalled on the nameplate you will find on the machine. ® S.E.F.A Z.I PASTABRAC 11 260 ESPERAZA – (France) Tel :+33.(0)4.68.74.05.89 Fax :+33(0)4.68.74.24.08...
V0116 III. OVERVIEW Safety cells Touch Manometer screen panel Pressure regulator Emergency stop Main plug (400V) Neutral and earth connections Reset Filter Emergency Cycle start stop button This heat press machine is standard to the labour laws to ensure the security of the user. It is designed to ensure the production with total reliability.
V0116 IV. USING THE MACHINE The press SUBLIMAX 1812 was designed for the application of transfers of all grades. This equipment has been tested in our workshops to get a one year warranty against manufacturing defects. Power settings, mechanical and pneumatic submitted by our technicians in the workshop as well as the security established on the machine should never be changed.
Page 7
They should be restored in case of removal for maintenance work. The must be maintained in good running order during the production. The press SUBLIMAX 1812 is equipped with security systems preventing from pinching risk. The main security devices are:...
V0116 2. INSTALLATION USE BY QUALIFIED STAFF ONLY • Lower the machine from its packaging with a forklift • Place the machine on its operating location. • Remove all items related to packaging: paper, cardboard, plastic film, wood, etc..•...
V0116 B. Mounting arm assembly right Handing over door accompany the cables to the arm inside the cap. Screw and tighten the 4 screws M8-12 curved Page 9...
V0116 C. Mounting the support bar Screw and tighten the 4 screws curved M5-12 D. Removing motor pinion Unscrew and remove the screw TFM5-12 + Washer. Remove the motor pinion pulling. If necessary, relieve the weight of the upper frame by slightly raising.
V0116 E. Reassembly motor pinion Position The upper rear frame (blue in the figure) And the lower frame at the front (in pink on the drawing) Reassemble the motor pinion ensuring continuity pins made on both the pinion and the rack. If necessary, relieve the weight of the upper frame by lifting slightly.
V0116 F. Mounting free pinion set Reassemble the free pinion set through the right door. Ensure continuity marks made on both the pinion and rack. And screw the screw TF M5-16. Page 12...
V0116 G. Mounting extraction fan Place the fan on the flange and screw the 3 screws curved M5- Connect the ventilator plug HAVING DONE CORRECTLY THE ASSEMBLY AND POSITIONING OF EQUIPMENT ON THE PLACE OF OPERATIONS • Electrically connect the press (380 Volt + Neutral + Earth / 50 or 60 Hertz). The red jack is located on the left side of the machine.
V0116 V. DESCRIPTION OF THE OPERATING CYCLE 1. COMPLETE CYCLE 1. Turn the machine by flipping the power switch located on the left side of the chassis. Press the push button reset (screen lights up and displays the home page) 2.
V0116 2. OPERATING WITH THE TOUCH SCREEN Summary Dimensions of the 4 areas Control T° adjustment area 1 T° adjustment area 2 Pressing time adjustment T° adjustment area 3 T° adjustment area 4 interrupt the pressing cycle without moving During pressing: interrupts the press and trade decks decks.
Page 16
V0116 Settings Allows to correctly reposition the deck up under the During the pressing : heating plate stops the pressing cycle and switches decks. Off pressing : switches decks. Allows to correctly reposition the deck down under the heating plate Offset Aspiration Allows the offset of each zone.
Page 17
V0116 Diagnostics Probe diagnostic I/O diagnostic Indicates the faulty probe and the type of error Indicates the status of sensors and actuators Shows the parameters used to control each area Page 17...
V0116 3. PRESS SETTINGS USE BY QUALIFIED STAFF ONLY A. TEMPERATURE SETTING Set the temperature for each area, refer to the operation of the touch screen, § Controls, note Pressing the control button brings up the following temperature display : Nota : This screen is the same for all digital input.
V0116 VIII. ELECTRICAL PANEL 4 zone Frequency Static relay zone 1 Touch Motor regulator inverter screen reducer Static relay zone 2 Static relay zone 3 Static relay zone 4 Aspiration relay Emergency stop contactor Fuseholder zone 1 Fuseholder zone 2 Fuseholder zone 3 Fuseholder zone 4 Main fuses...
V0116 IX. MAINTENANCE USE BY QUALIFIED STAFF ONLY ANY SERVICING INTERVENTION MUST BE DONE WHEN THE MACHINE IS OFF AND LOCKED (ELECTRIC AND PNEUMATIC ENERGIES UNPLUGGED) 1. SERVICING Heat transfer press SEFA ® require little maintenance. To ensure proper operation, follow the preventive guidelines listed below.
V0116 3. QUICK REPAIR ADVICES ANY SERVICING INTERVENTION MUST BE DONE WHEN THE MACHINE IS OFF AND LOCKED (ELECTRIC AND PNEUMATIC ENERGIES UNPLUGGED) SYMPTOMS POSSIBLE BREACKDOWNS REPAIRS The plug is not connected Check the mains and see if the machine is connected.
V0116 4. MAINTENANCE LOG The control and maintenance operations indicated in this table must be done regularly so as to check the functioning state and the reliability of the press. Resistors Number Pressure Air filter Rubber Changed Date Cylinder control Observations of hours control...