Jedi -700 Manual

Electromechanical actuator for spring and counterweight balanced doors

Advertisement

www.remotecontrolgates.co.uk
ELECTROMECHANICAL ACTUATOR FOR SPRING
GB
AND COUNTERWEIGHT BALANCED DOORS
JEDI
IL n. 321
EDIZ. 01/11/2013

Advertisement

Table of Contents
loading

Summary of Contents for Jedi JEDI-700

  • Page 1 IL n. 321 EDIZ. 01/11/2013 www.remotecontrolgates.co.uk JEDI ELECTROMECHANICAL ACTUATOR FOR SPRING AND COUNTERWEIGHT BALANCED DOORS...
  • Page 2: Technical Specifications

    Protection fuses SOURCE = 2,5A SOURCE = 2,5A the partly completed machinery model(s): Door area < 10m < 15m JEDI-700 (*), JEDI-700-120V JEDI-1000 (*), JEDI-1000-120V Average speed 110mm/s 110mm/s Identification number and year of manufacturing: typed on Peak force 700N...
  • Page 3: Important Remarks

    EN 12453 allows. • The use of JEDI in dusty, saline or explosive environment is forbidden • The opener is designed for operation in dry rooms exclusively.
  • Page 4: Installation Layout

    (carry out a balance weight adjustment, if necessary). Before installing JEDI, please check the following basic points: • It is advisable to install the geared motor in the centre of the •...
  • Page 5 INSTALLATION OF GUIDE SECTION BAR 1. Remove the section bar from its cardboard packaging and check its integrity. 2. Unfold the section bar as indicated in the figure below. 3. Once the section bar is elongated, slide the connecting section bar R to the end position indicated by the two holes Q on the chain-guide section bar.
  • Page 6: Installation Of Motor On Section Bar

    INSTALLATION OF MOTOR ON SECTION BAR 1. Insert the shaft/pinion adapter on the motor shaft. 2. Position the section bar A on the motor: the shaft/pinion adapter B must fit into the seat on the section bar. Verify that the section bar fits snuggly against the motor.
  • Page 7: Release Of The Automation

    Only for sectional and spring operated garage doors RELEASE OF THE AUTOMATION Fasten the draw slide I on the upper portion of the door In order to release the automation from inside, pull the knob maintaining the previously marked reference points. downwards.
  • Page 8: Electrical Connections

    ELECTRICAL CONNECTIONS The control panel inside JEDI is already cabled. You just need to plug it in the electrical outlet to proceed with operational parameter programming. To connect the photocells and the START button, please refer to the following diagram:...
  • Page 9 SET-UP OF OPERATIONAL PARAMETERS JEDI is equipped with a practical interface that allows rapid and simple on-display programming using four keys: , +, -. Preliminary operations: 1. Move the door so as to hook on the drive trolley. 2. Power up the device: the courtesy light comes...
  • Page 10 3. Self learning of the forces When the door stops, press Press the key, Press the key: When the door stops, press the the display shows flashes - the door opens key to confirm. key to save the settings. Press the key once more The display shows to continue - the door closes...
  • Page 11 7. Automatic closure (default: 0 – function deactivated) If this function is activated, the device automatically closes the door after the set period of time. Prior to closing the door, the device emits BEEPs for 20 seconds. Press the + key to activate Press the key, Press the...
  • Page 12: End Programming

    10. End programming To exit the programming and store the settings of the different parameters, it is necessary to follow this procedure: Release the key: the Press the + key until the segments of the display Press and hold the display shows illuminate one at a time for 5 seconds:...