INSTALLATION INSTRUCTIONS OPERATION MANUAL SGHNX Series NEMA 4X UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty...
IMPORTANT INSTALLATION INSTRUCTIONS WARNING – To reduce the risk of severe injury or death to persons: READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2. Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to cables, spring assemblies, and other hardware before installing the operator.
SPECIFICATIONS MOTOR Duty Cycle: Continuous duty Horsepower: 1/2 hp, 3/4 hp, 1 hp, 1½ hp, 2 hp Speed: 1700 RPM 208/230, 460, 575 – 3 phase Voltage: 230 volt 3 phase motor is suitable for use with 208 volts (see Wiring Diagrams and Appendix 3 for wiring change instructions) Current: See motor nameplate ELECTRICAL...
TYPES AND SIZES OF DOORS Consult factory for details. INSTALLATION INSTRUCTIONS INSTALLATION POSITIONS (for 1/2hp and 3/4hp) Consult factory for changes in installation positions. NOTE: Any change in mounting position may result in a change of operator rotation and consequently in a change of control functions. Consult factory for any changes. (LH=LS and RA, RH=RS and LA) Operators mounted in alternate positions (LA, RA) require the long mounting legs in lieu of the standard short mounting legs.
Page 5
INSTALLATION POSITIONS (for 1hp, 1-1/2hp, 2hp) Consult factory for changes in installation positions. NOTE: Any change in mounting position may result in a change of operator rotation and consequently in a change of control functions. Consult factory for any changes. (LH=LS and RA, RH=RS and LA) Operators mounted in alternate positions (LA, RA) require a straight mounting plate in lieu of the standard bent plate.
OPERATOR MOUNTING 1. Before the operator is installed, verify that the door is properly operating and balanced. 2. Make sure the layout of the mounting holes on the bracket are correct. 3. Bolt the operator mounting plate to the door bracket plate. 4.
Page 7
6. When the operator assembly is attached to the door bracket, be sure the door driven sprocket is properly aligned with the operator drive sprocket before securing the driven sprocket to the shaft. 7. The shelf or bracket must provide adequate support for the operator. Prevent play between the operator and the door shaft.
Page 8
DRIVE CHAIN ADJUSTMENT NOTE: Use correct type, size and proper length of roller chain. 1. Adjust the drive chain by tilting or move the operator so that there is about 1/4” of slack when the chain is depressed. Note: The set screw included in the operator may be used for adjustment. (See figure 1- S1 location for 1/2hp and 3/4hp), (See figure 2 - T1, T2, T3, T4 for 1hp and 1½hp).
Page 9
HAND CHAIN ADJUSTMENT Cut and reconnect chain with different color link provided. Chain Holder Optional SGHNX Series REVISION # 0000 DATE: 03/07/2017...
LIMIT SWITCH ADJUSTMENT Make sure the limit cams are positioned between the limit switch actuators before proceeding with adjustments. 1. Open / Remove the control panel cover. 2. Open or close door to determine the moving direction of the limit switch cams. 3.
WIRING INSTRUCTIONS Disconnect power at the fuse box before proceeding with any wiring. WARNING 1. Do not install any wiring or attempt to run this operator without checking the wiring diagram located on the inside of the control box cover. 2.
CONTROL WIRING If the door is not visible from the control station, or if any device other than the control station is used to activate the door, an entrapment protection device must be installed on the door. Failure to install an entrapment WARNING protection device may result in serious injury or death to person(s) trapped beneath the door.
Page 13
Disconnect power at the fuse box before proceeding with any wiring. WARNING 2. Locate the control station where the user can clearly see the operation of the door. Mount the enclosed placard adjacent or near the door. Controls shall be far enough from the door, or positioned such that the user WARNING is prevented from coming in contact with door while operating the controls.
A. Control Overview: A-2. TIMER E.OP M.CL M.OP Timer ON: Momentary Pressure Open OFF: Constant Pressure ON: Momentary Pressure Close OFF: Constant Pressure Auto Open Safety Switch Three-phase power source See operator plate for correct A-3. voltage. IR: P5&P6 ELR:E5&E6 1.Stop 7&8 Close (ELR-End of line resistor).
B. Auxiliary Function: 24VAC Push button Radio control Radio control B-2. B-2. B-1. B-1. CN12 CN13 CN14 B-2. B-2. Open door Open door 1. 1&2 Open limit dry contact 2. 3&4 Close limit dry contact Close door Close door 24VDC MAX 0.5A 24VDC MAX 0.5A Stop door Stop door...
C. Timer Instruction: Note: To enable timer(s) – 1) Must switch Timer Switch S10 to ON. (See figure A-2 on Page 13 for location.) 2) Must remove jumper on Terminal PCB-CN2 (23,24). (See figure A-1 on Page 13 for location.) C-2.
Page 17
(2) To Set Timer 1 (Mid-open Timer): Remove jumper from terminal (23,24) to enable Timers. Turn timer switch S10 to ON. Press and hold for 5 seconds. Display will flash. to increase or to decrease time. Press to save setting. Without pressing, no adjustment is saved. Mid-Open Timer Set the Max.
Page 18
(4) To Set Timer 3 (Buzzer Timer): Remove jumper from terminal (23,24) to enable Timers. Turn timer switch S10 to ON. Press and hold for 5 seconds. Display will flash. to increase or to decrease time. Press to save setting. Without pressing, no adjustment is saved. Door Open Warning Timer Set the Max.
D. LCD Display Instruction: Display Status Display Status T1 or T2 or T3 T1 setting setting completed T2 setting Door closing T3 setting Door opening E. Light Indication: LED17 Open button ON: Activated OFF: Not activated LED3 Door open limit ON: Door at open limit.
Page 20
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 21
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 22
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 23
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 26
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 27
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 28
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 29
SGHNX Series REVISION # 0000 DATE: 03/07/2017...
Page 30
Reference SGH series terminal connections External Interlock Control Station Timer Defeat Photo eyes ELR sensing Push Button or IR sensing edge Close Jump when no edge external interlock warning Stop Open Close is connected. signal 24VDC Control panel is wired with momentary pressure open and constant pressure close. A one-second delay on reverse is standard.
IMPORTANT SAFETY INSTRUCTIONS WARNING –To reduce the risk of severe injury or death: READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with door controls. Keep the remote control (where provided) away from children. 3. Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened.
OPERATING INSTRUCTIONS 1. If a 3-button control station is used to operate the door, push the “OPEN” button to open the door, push the “CLOSE” button to close the door, push the “STOP” button to stop movement of the door while opening or closing.
MAINTENANCE INSTRUCTIONS The brake is a self-adjusting brake. It is maintenance free. The brake assembly requires no additional adjustments for its lifetime. If an entrapment protection device is used, i.e. sensing edge or photoelectric sensors, please consult the manufacturer for maintenance instruction. Disconnect power supply to the operator before servicing.
Page 34
APPENDIX 1 Multiple Sensing Devices Connection nstruction Dual Photo eyes Connection Module Warning: Power OFF When Connecting. QST-SGN4-SB-ADA PTER-1 Plug back the jumper Unplug the jumper connector connector if no additional to add modules. module is used. Dual photo eyes connection module connects on CN3 Primary Sensing Device Connection P art No:...
Page 35
APPENDIX 2 Control Connections Diagrams CCD-PCB-A01 Control Wiring for 3 Button Stations Control Wiring for Key Switch with Stop Button Key Switch with Stop Button 1 Set of 3 Button Stations 3-1 BUTTON KEY SWITCH Key switch OPEN OPEN CLOSE OPEN OPEN OPEN...
Page 36
APPENDIX 3 Control Connections Diagrams CCD-PCB-B02 W iring 3 Button Stations With Key Lockout 1 Set KEY LOCKOUT 3 BUTTON OPEN OPEN OPEN CLOSE CLOSE CLOSE STOP STOP Key switch STOP With and without key lockout KEY LOCKOUT 3-2 BUTTON STOP STOP OPEN...