Solbrake / SMB's output. * Unit must be grounded to ensure correct operation, safety and to prevent damage. * Check that Power Factor capacitors are not connected to the output side of the Solbrake / SMB.
Page 3
This Rest time + Braking time minimizes the motor heating. Note: If a higher duty cycle is required select a higher Solbrake (SMB) type to allow enough brake time current. Wood Saw Mains Voltage (line to line)
Solbrake / SMB Wiring Check that Motor's Full Load Ampere (FLA) is lower than The Solbrake / SMB (10-17) are meant for installation on a or equal to Solbrake / SMB Full Load Current (FLC) and Din-Rail. See options list for other Din-Rail ratings.
Mode of Operation Stop signal opens motor contactor The Solbrake / SMB incorporates the following built-in that in turn initiates the closing time delays: of brake contacts C The Thyristor is switched on and Power ON fire (to inject DC current to the...
- auxiliary N.C contact of contactor C contactor C acts as an interlock preventing operation of motor The yellow LED on Solbrake / SMB's front panel will light contactor as long as brake contactor is closed. up indicating that brake contactor is closed.
Page 7
Emergency Stop closes and initiates the braking U V W rocess. When Emergency Stop contact is opened, C1 Control contactor opens and the Solbrake / SMB is operated, initiating the braking process. Reversing - SMB Contactor. Cf - Forward Contactor Cr - Reversing Contactor Interlocked Contactors.
Braking torque turned off. Determines the value of DC current the Solbrake / SMB injects to the motor. The Solbrake / SMB can produce a Note: Set Braking Time potentiometer t to a slightly braking current of up to four times motor's nominal current.
Page 9
Title numbers in Thyristor I Ultra Fast Acting fuse Semicon fuse Reference /Publication Protistor series Amp's allowed links Solbrake / SMB 8 GSGB30 500V - 40A 6,9 gRB17.63 G220967 / A600070 Solbrake / SMB 17 5000 GSGB55 500V - 50A 6,9 gRB17.63...
Page 11
Technical Specification Solbrake 105-210A 280 263 L2 U V Solbrake 310-390A 63.4...
Page 12
DC Injection ON - Yellow Illuminates when DC current is being injected to the motor windings. Temperatures Operating -10° to 50°C Storage -20° to 70°C Relative humidity 93 % - non condensed \\SOLSRV1\DATA\Catalogs and Marketing materials\Instruction Manuals\Solbrake Instruction Manual.doc...