STOVES
European Standard Certification UNE EN-13240 stoves
LISEO s.r.o. Folknářská 1246/21 Děčín 2 – Nové Město 405 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CANARIA Air tight and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LISEO CANARIA Air tight

  • Page 1 LISEO STOVES European Standard Certification UNE EN-13240 stoves LISEO s.r.o. Folknářská 1246/21 Děčín 2 – Nové Město 405 02...
  • Page 2: Table Of Contents

    INTRODUCTION ………………………………………………………………………………………………………………………….3 1. GUARANTEE CONDITIONS …………………………………………………………………………………….3 1.1. SAFETY WARNINGS …………………………………………………………………………………………………………..3 1.2. GUARANTEE CONDITIONS ………………………………………………………………………………………………….3 2. INSTALLATION IN ACCORDANCE WITH UNI 10683 …………………………………………………..4 2.1. OPERATING AREA …………………………………………………………………………………………………………….4 2.2. PRECAUTIONS ………………………………………………………………………………………………………………….4 2.3. CONNECTION TO THE EXTERNAL AIR INTAKE ………………………………………………………………………4 2.4. CONNECTION TO THE FLUE PIPE ………………………………………………………………………………………..5 3.
  • Page 3: Introduction

    LISEO installation and therefore the proper functioning of the installed product. They are not part of the guarantee those parts Pay special attention to the laws subject to normal wear such as joints, glass and any and regulations in the area of the all parts that can be removed from the fire box.
  • Page 4: Installation In Accordance With Uni 10683

    INSTALLATION AND USE MANUAL INSTALLATION IN ACCORDANCE WITH UNI 10683 2.1. OPERATING AREA Ventilation: To allow proper operation, verify that the oxygen required for combustion can be obtained in sufficient quantity in the place where it is to install the appliance. Location of appliance: Choose a central location in the room that favors a good distribution.
  • Page 5: Connection To The Flue Pipe

    INSTALLATION AND USE MANUAL CONNECTION TO THE EXTERNAL AIR INTAKE 2.4. Maximum inclination 45 ° relative to horizontal. The smoke exhaust system must be unique to the insert (Not allowed pipe discharges common to other fireplace). Fumes discharged is made from the opening situated at the top. The discharge pipe must be connected to the outside using appropriate tubes and eventual isolation.
  • Page 6: Dimensions And Technical Specifications

    INSTALLATION AND USE MANUAL 3. DIMENSIONS AND TECHNICAL SPECIFICATIONS 3.1. DIMENSIONS AND TECHNICAL SPECIFICATIONS...
  • Page 7 INSTALLATION AND USE MANUAL...
  • Page 8 INSTALLATION AND USE MANUAL...
  • Page 9 INSTALLATION AND USE MANUAL...
  • Page 10 INSTALLATION AND USE MANUAL...
  • Page 11 INSTALLATION AND USE MANUAL 3.2. CONTROLES Clean glass air Air 2ª Air 1ª Canaria Premium...
  • Page 12 INSTALLATION AND USE MANUAL Clean glass air Air 1ª L71 Black...
  • Page 13 INSTALLATION AND USE MANUAL Air 1ª Air 2ª Optional in certain models...
  • Page 14: Installation And Assembly

    INSTALLATION AND USE MANUAL 4. INSTALLATION AND ASSEMBLY IMPORTANT The chimney can only be installed and connected to the flue by a specialized technician, respecting in every time the national and local standards and in compliance with UNI 10683. 4.1. PREPARATION AND UNPACKING When you unpack the fireplace, check for perfect operation, as well as the possible presence of shipping damage.
  • Page 15: Operation

    INSTALLATION AND USE MANUAL 5. OPERATION PRE-LIGHTING WARNINGS 5.1. Make sure you have read and perfectly understood the contents of this instruction manual. Remove from the fireplace and the door all accessories, adhesives and equipment that could burn. During the first lighting, the paint completes its drying and hardens. If you touch the paint, it could cause some damage.
  • Page 16: First Lighting

    INSTALLATION AND USE MANUAL FIRST LIGHTING 5.3. In the first lighting, you are advised to proceed with caution and use fine and dry wood. Place the primary air input fully open (see figure). DO NOT USE under any circumstances: alcohol, gasoline or any other explosive flammable substances. During the first lightings, it could release fumes or unpleasant odors caused by the drying of the paint;...
  • Page 17: Maintenance And Cleaning In Charge Of The User

    INSTALLATION AND USE MANUAL 6. MAINTENANCE AND CLEANING IN CHARGE OF THE USER ATENTION Only clean the chimney when it's completely cold. 6.1. CLEAINING OF THE GLASS To clean the glass, you can use specific products, or some white ash and a newspaper page. Premium Clean regularly the glass;...
  • Page 18: Cleaning To Be Dealt With By Specialized Technician

    ATTENTION For maintenance, we advise to contact a specialized center that will be in a position to define, according to the type of installation and depending on the use made of it, the frequency of cleaning and maintenance. s.r.o. ©Liseo...