  • Page 1 1.9GHz Wireless Access Point K-SAP14...
  • Page 2: Table Of Contents

    CONTENTS Important safety instructions Major operating controls and their functions Operating procedures Functions and settings Connections Precautions for installation Installation Specifications Accessories...
  • Page 3 FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4 WARNING: - The mains plug or an appliance coupler shall remain readily operable. - To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. - The connections should comply with local electrical code. - The installation shall be carried out in accordance with all applicable installation rules.
  • Page 5: Important Safety Instructions

    Important safety instructions 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  • Page 6: Major Operating Controls And Their Functions

    Major operating controls and their functions...
  • Page 7 E1 CNT: provides E1 signal * output controlled by K-SAP14. E2 CNT: provides E2 signal * output controlled by K-SAP14. * Those are available when K-SAP14 is used. Settings of E1 and E2 are performed with K-SAP14. E2 ACK: connects acknowledge signals responding to E2 output.
  • Page 8: Operating Procedures

    Operating procedures Operation of Simple PA. 1. Specify output classroom on PC GUI it is possible to select "A specific classroom" or "All classroom" 2. Public Address is heard in classroom after the request tone of Simple PA sounds.
  • Page 9 Operation of Intercom (1) Intercom requested form Administrator’s room to Classroom 1. Select the destination on PC GUI and request Intercom call. 2. The request tone of Intercom sounds from ceiling speaker. 3. Teacher respond to Administrator by pressing "INT/E1" button of Pendant microphone. 4.
  • Page 10 (2) Intercom requested form Classroom to Administrator’s room 1. Teacher requests a Intercom call to Administrator by pressing "INT/E1" button od Pendant microphone. 2. Administrator respond to the destination from PC GUI. 3. The notification tone of Intercom call sounds from ceiling speaker after a call was established. 4.
  • Page 11 Activate E2 Press the both sides [E2] button of the Pendant microphone for 2 seconds or more will activate E2 output and transmit location information of Pendant microphone. The voice of Pendant Microphone monitoring The voice of Pendant Microphone sends to Administrator's room in case of requested from server PC. Number of audio voice that can send is 1 path per DECT AP.
  • Page 12 PC operation PC GUI reference display ( intercom ) The example of operation Intercom: 1. Input DECT-AP-IP address/ user name / password. 2. Select the receiver of a classroom which wants to pass intercom. 3. Push “Intercom start” button. (Operation of Intercom/ Simple PA / Alert monitor can be directed.) A following CGI command is used for operation.
  • Page 13: Functions And Settings

    ● E2 CNT function These functions are available when K-SAP14 is used. When E2 is controlled with the microphone, control signals are provided from the E2 CNT terminal of this unit. Selection between E2 is made at the microphone side.
  • Page 14 LED lighting indication1 [POWER/LINK] Three LEDs of this unit operate as an operation indicator indicating the state in operation and as a reception indicator indicating the receiving state of the microphone under normal conditions. In addition to those above, the LEDs operate as an indication LED indicating the operating state of this unit.
  • Page 15 DIP switch setting Switch Name Function Setting Selecting “For ONLY Alert” or ”For sound broadcast”. For sound For ONLY Alert* broadcast Version display To display the software version by LED lighting Activated Deactivated * pattern as the power is turned on. Initialize Factory setting Initialize all internal setting to the factory-shipments State...
  • Page 16: Connections

    Connections ● LAN(PoE)connection ■ Connection to control terminal ● Cable processing Before connection, prepare the cable as shown in the drawing at right. Note: • Stranded wire is highly recommended. • Wire insulation must be removed. • Do not use solder to tin the wire. •...
  • Page 17 ● Connection of ALERT BUTTON terminals An external device is connected between ALERT BUTTON and GND. These terminals operate by closing their circuits. The GND terminal is connected to GND in this unit. A set of “dry relay” contacts are recommended to activate these features. ALERT BUTTON ALERT BUTTON Input format: transistor input...
  • Page 18: Precautions For Installation

    Precautions for installation The installation should be carried out following local standards for electric products. Warning • Be sure to contact your dealer for installation. Before installing, turn off the power of the connecting product. In addition, be sure to read "Precautions" carefully and follow the instructions.
  • Page 19: System Setting

    Preparation Installation System Setting The planning of equipment layout First: Arrangement of apparatus is planned using a planning tool. 1. The classroom in which a receiver is installed is decided. 2. DECT-AP is arranged in the position where radio reaches a receiver. (They are a maximum of four receivers which can connect with one DECT-AP.) 3.
  • Page 20: Installation

    Installation. Warning • Before installing, be sure to turn off the power of the receiver. There is a risk of electric shock. ■ Installation of the receiver ● When using a ceiling panel When installing the receiver and cables in a removable ceiling, follow the instructions shown below. 1 Make a hole in the ceiling panel Remove the ceiling panel, drill a hole of approx.
  • Page 21 Step 1 Step 2...
  • Page 22 ● When using a wall When installing the receiver and cables in a removable wall, follow the instructions shown below. 1 The mount bracket is fixed to a wall with a driver using a screw. Note: • Fix this unit firmly with specified torque with a tool such as a torque driver. 2 Connect the necessary cables to the receiver.
  • Page 23 Step 1 Mount bracket Step 2 Screw cover Step 3 Screw driver...
  • Page 24 Setting of the Units (a)[For sound broadcast] DECT-AP Pairing registration of the receiver of a DECT-AP Please supply a power supply to a receiver. (A receiver will be in a pairing registration state automatically, if a power supply is switched on in the state of factory shipments.) After that, DECT-AP is turned on.
  • Page 25: Specifications

    Specifications General Power PoE (IEEE 802.3af ) Class Class1 Operating temperature range 0°C - 40 °C {32 °F - 104 °F} Dimensions 7.28"(W) x 6.3"(H) x 1.26"(D) (185mm(W) x 160mm(H) x 32(D) ) (excluding projections) Mass Finish ABS resin white color RF communication Radio Standard DECT...