LEO
Light
Installation Guide
Included components
20ft
12ft
16ft
25ft
Pole with base plate
Standard
For twist lock
Twist lock receptacle,
Pole  cap
Tools Required
• Safety glasses
• Wrenches, 1‐1/8" 
• Screwdrivers, Phillips and straight blade
• Wiring tools and connectors
• Proper personnel, crane or lift for hoisting unit onto anchors
• Level
• Dimming control, if required
• Hex keys
• 5/16" hex key socket with 1‐1/2" extension. Flex drive or universal is helpful.
• Twist lock photo eye, if required
ASSEMBLE WITH CARE! Pangard II Polyester Powdercoat is a strong, long‐lasting finish.  To protect this 
finish during assembly, place unwrapped powdercoated parts on packaging foam or other non‐marring 
surface.  Do not place or slide powdercoated parts on concrete or other hard or textured surface – this will 
damage the finish causing rust to occur.  Use touch‐up paint on any gouges in the finish caused by 
assembly tools.
22in
28in
Nut cover with 1/4‐20 
Luminaire
x 5/8" button head 
cap screw
Single
Single
3/8‐16 x 1‐1/2" socket head 
Double
Double
cap screw with lock washer
28in  Clamp
22in  Clamp
Shorting cap for
Twist lock,
assembly (optional)
optional
optional
Landscape Forms is not responsible for site preparation and footings.  Refer to the 
installation guide for the LEO light anchor kit for installing the anchor bolts.
CAUTION! This unit is heavy. To avoid injury or damage to the finish, we recommend using 
a crane or lift for hoisting the unit onto the anchors.
WARNING! Pole mounted luminaires must be attached either before or immediately after 
pole installation. Failure to do so may cause vibration damage to the pole and will void the 
pole warranty.
INSTALLATION PROCEDURE FOR LIGHT POLE:
1.
Lift the light pole into position over the installed anchors (refer to LEO anchor kit 
installation guide) as shown in Fig. 1.  Ensure that the base plate is resting on all four 
washers.
2.
Install washer, lock washer and hex nut as shown in Fig. 2.
3.
Plumb and level the pole and tighten all anchors.
4.
Install clamp on pole as noted in Fig. 3.
Cover plate 
5.
Remove access panel on luminaire arm as shown in Fig. 4. Retain screws and washers.
6.
Using a hex key socket with extension, install luminaire to clamp as shown in Fig. 5.
7.
Connect wiring to connection terminals in the luminaire. Refer to wiring diagrams on 
pages 2 and 3.
8.
Install the top cap on the pole (shipped with the pole). If the unit has a twist lock 
receptacle, assemble the receptacle and the top cap as shown in Fig. 8 and connect 
wiring before installing the top cap. Install provided shorting cap or photo‐electric 
control.
9.
Replace the access panel on the luminaire arm.
10. Install the nut covers as shown in Fig. 9 or the cover plate as shown in Fig. 10.
Fig. 1 – Pole orientation
Date: May 19, 2017
www.landscapeforms.com
Ph: 800.521.2546
Fig. 2 – Install pole
Page 1 of 3

Advertisement

loading

Summary of Contents for Landscape Forms LEO

  • Page 1 Light Date: May 19, 2017 Installation Guide www.landscapeforms.com Ph: 800.521.2546 Included components Landscape Forms is not responsible for site preparation and footings.  Refer to the  installation guide for the LEO light anchor kit for installing the anchor bolts. CAUTION! This unit is heavy. To avoid injury or damage to the finish, we recommend using  22in 28in a crane or lift for hoisting the unit onto the anchors. Nut cover with 1/4‐20  Luminaire x 5/8” button head  WARNING! Pole mounted luminaires must be attached either before or immediately after  cap screw pole installation. Failure to do so may cause vibration damage to the pole and will void the  pole warranty. Single Single INSTALLATION PROCEDURE FOR LIGHT POLE: Lift the light pole into position over the installed anchors (refer to LEO anchor kit  3/8‐16 x 1‐1/2” socket head  Double Double 20ft 12ft 16ft 25ft installation guide) as shown in Fig. 1.  Ensure that the base plate is resting on all four ...
  • Page 2 Light Date: May 19, 2017 Installation Guide www.landscapeforms.com Ph: 800.521.2546 Fig. 3 – Install clamp Fig. 4 – Remove access panel Fig 6. – luminaire wiring connection Fig. 5 ‐ Install luminaire Fig. 9 – Install nut covers Fig. 10 – Install cover plates Fig. 8 – Install optional twist  Fig. 7 – Install top cap lock receptacle to top cap Page 2 of 3...
  • Page 3 Light Date: May 19, 2017 Installation Guide www.landscapeforms.com Ph: 800.521.2546 PROCEDURE FOR WIRING LEO: The LEO light luminaire is assembled at the factory.  The light cartridge is mounted into  the head of the dome and will not need to be removed during installation.  The LED  cartridge is wired to the driver (located in the arm of the luminaire) at the factory.  Use of  LED drivers other than the supplied unit is not recommended and will void the warranty.  The wiring schematics are to be used to connect the unit to line voltage.  It is the  responsibility of the installer to make sure that all connections are made in accordance  with the NEC and local building codes.  Connection hardware not included. Line‐in wires should be connected to the terminal block as shown. Optional dimming  control is not included. WIRING DIAGRAM:  22in luminaire, without twist lock WIRING DIAGRAM:  28in luminaire, without twist lock Page 3 of 3...

This manual is also suitable for:

Leo28Leo22