Advertisement

Model 1700
TM
Max Liquid Temp - ºF (ºC)
Max Liquid Pressure - PSIG (BARG)
Control Air Min - PSIG (BARG)
Control Air Max - PSIG (BARG)
Depth (Inlet/BV) - " (cm)
Balance Line - " NPT
Max Capacity GPM (l/h)
United States Patents: 4,444,217 4,562,855 4,574,829 5,004,004 5,014,735 5,983,919
022802 Model 1700-IG

SPECIFICATIONS

Model
Part Number
Ht - " (cm)
Width - " (cm)
Inlet/Outlet - " NPT
Control Air - " NPT
Weight - LBS (KG)
TM
TM
1700
# 870100
170 (76.7)
170 (11.7)
40 (2.8)
130 (9.0)
11 (27.9)
9-1/4 (23.5)
10-1/2 (26.7)
1/2
1/4
1/8
3 (681.4)
21 (9.5)
Page 1
INSTALLATION
GUIDE
Model 1700
TM
The patented Model 1700
designed for removing condensate from
compressed air systems. Since it is total-
ly pneumatic, it does not require any
electricity and can be easily installed
using simple piping connections at any
point in a system including remote loca-
tions. It can handle pressures up to 170
PSIG and liquid temperatures up to
170
F. It has 1/2" NPT inlet and outlet
O
ports and a full 1/2" smoothly contoured
condensate flow path. The industrially
robust, highly reliable Model 1700
few moving parts and at 21 pounds, can
stand up to the most demanding applica-
tions with minimal maintenance.
INDEX
Installation......2 Install Locations......12
Start-up & Troubleshooting.................3
Dimensional Print...............................4
Component Parts Drawing...................6
Frequently Asked Questions..................8
Drain-All Solves Problems....................9
Team Drain-All...................................10
Warranty......11
Warranty Card ......11
1170 Topside Road
37777
Phone: 865-970-9290
Fax: 865-977-6658
E-mail: Info@Drain-All.com
WEB SITE: Drain-All.com
The Drain-All, Inc. Quality System is
ISO 9002 Certified
was
TM
has
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Model 1700 and is the answer not in the manual?

Questions and answers

Joseh Augustine
May 24, 2025

what is the maximum vertical lift in feet?

1 comments:
Mr. Anderson
May 26, 2025

The maximum vertical lift for the Drain-All Model 1700 is not specified in the provided information.

This answer is automatically generated

Joseh Augustine
May 23, 2025

I have to drain compressed air condensate(100psi) with a 25 vertical lift and then send the water 356' horizontal distance.

1 comments:
Mr. Anderson
May 25, 2025

The maximum vertical lift the Drain-All Model 1700TM can handle at 100 psi is approximately 10 feet, and the maximum horizontal distance is approximately 100 feet.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Drain-All Model 1700

  • Page 1: Table Of Contents

    F. It has 1/2” NPT inlet and outlet ports and a full 1/2” smoothly contoured condensate flow path. The industrially robust, highly reliable Model 1700 few moving parts and at 21 pounds, can stand up to the most demanding applica- tions with minimal maintenance.
  • Page 2: Installation

    Model 1700 , a review of the following balance line is tied back into the vessel 1. Prior to installing the Model 1700 items will help make the right decision being drained, such as connecting the blow down the vessel being drained to regarding options which could be used to balance line at a tee fitting on the vessel’s...
  • Page 3: Start-Up & Troubleshooting

    Model 1700 air lines and then into the center tube, B. Liquid inlet shut-off valve is closed.
  • Page 4: Dimensional Print

    MODEL 1700 DIMENSIONAL PRINT Page 4 022802 Model 1700-IG...
  • Page 5: Product Technology How It Works

    The balance line port is a hole through is sitting on the base and is at the lowest its highest position as shown. The float the head of the Model 1700 that goes level. The float magnet exerts a magnetic magnet is raised up past the center tube into the reservoir.
  • Page 6: Component Parts Drawing

    MODEL 1700 COMPONENT PARTS DRAWING 022802 Model 1700-IG Page 6...
  • Page 7: Parts & Materials Of Construction

    Double O-ring Viton Stem Seals, Nickel Plated Brass 302370 Coupling Nut, 1/2" - 13 x 1-3/4" L Zinc Plated Steel 301130 Installation Kit Includes: (2) Needle Valve-Brass (1) Straight Fitting-Brass (1) Elbow Fitting-Brass (1) 24' - 1/4" Dia LDPE Tube 022802 Model 1700-IG Page 7...
  • Page 8: Frequently Asked Questions

    Drain-All units handle normal All. Also, the use of check valves in mul- levels of debris found in most applica- No. Drain-All is a liquid drain and it will tiple drains to one Drain-All installation tions. Should there be an excessive drain oil, water, and particulates from the will not make this work properly.
  • Page 9: Drain-All Solves Problems

    All avoids this waste of compressed air the liquid reaches the predetermined trig- ELECTRICITY and the resulting pressure drop in the ger point. The Drain-All does not over- Timer valves require electricity. There is compressed air system by maintaining a drain or blow down the system.
  • Page 10 Drain-All, Inc. is an engineering, manu- ground in the photo above) is Drain-All, In addition to the Model 1700 there are facturing and marketing company with Inc’s flagship product used in facilities other Product Groups that can include an ISO 9002 certified quality system.
  • Page 11: Warranty

    FAX TO: 865-977-6658 Fill in the form below and keep it in this Installation Guide as your record. Make a copy to fax to Drain-All. Or you can mail a copy to Drain-All, Inc. Warranty Registration Dept., PO Box 609, Louisville, TN, 37777...
  • Page 12 In the drawing to the right, if the balance Fax: 865-977-6658 line were connected to the vessel or head- Vessel like air receiver tank above with low vessel bottom er pipe, the condensate would be filling Techservice@Drain-All.com Page 12 022802 Model 1700-IG...

This manual is also suitable for:

Model 1700-ig870100

Table of Contents

Save PDF