• All apparatus must strictly be used for the purpose it was designed to fulfil. The Comelit Group S.p.A. company will accept no responsibility whatsoever in case of misuse of the apparatus, in case of modifications carried out to the product for whatever reason and in case of use of accessories or material which prevent the installation from conforming with current standards.
Description 1. Status light: Uses different colours to indicate the result of the action performed: BLUE: Standby mode Flashing GREEN: Input in prpgress GREEN: Activation of relay number 1, following the input of an authorized code MAUVE: Activation of relay number 2, following the input of an authorized code Flashing PURPLE: Wait for programming of keypad code associated with badge WHITE: Activation of relays 1 and 2 the same time, following the input of an authorized code RED: Code, badge or transaction rejected...
Installation Positioning In order to comply with laws regarding accessibility, access control systems have to be placed et a height of between 0.9m et 1.30m. They must also be placed more than 0.4m from a wall angle or any other object which could restrict wheel chair access. On a wall...
Overall configuration Your SKR keypad is delivered with the following default settings: Master code 123456 Number of terms per code Relays associated with opening Validity counter Permanent Relay N°1 time delay 5 seconds Buzzer Relay N°1 Disabled Anti-Attack Mode Disabled...
[B7]. The advantage of the master badge is that it automatically carries out this operation; unlike the master code which requires manual activation of the register [B7] prior to programming badges. Only COMELIT badges are compatible with the keypad. (Badges authorize: SK9050B/A, SK9050G/A, SK9050GB/A, SK9050GG/A, SK9050GO/A, SK9050GR/A, SK9050GY/A, SK9050O/A, SK9050R/A, SK9050Y/A, SK9052.
Every time a button is pressed, its code will be emitted in 4 bits. For the badge, this will be in 32 bits. When you wish to use relays external to the SKR, set the value to 1. It is not possible Internal/ to use the keypad's internal relays and external ones simultaneously.
Example using the master badge 1. Present the master badge (programming mode), 2. input "B0" (select register B0), 3. then "300000" (3 characters/permanent backlighting/Wiegand disabled/internal relays/no anti-attack management/anti- attack button "0"), 4. & lastly "BB" (exit programming mode). Breakdown of button/reader stages in the example Button Reader Led status...
Programming/code deletion/opening badges Relay selection and opening code validity: code [B5] This register allows you to define the relays combined with an opening code/badge to be programmed. By default, it is Relay N°1 which is defined, combined with the value "0" on the counter (permanent validity). If your choice regarding the relay or the validity counter differ, it is absolutely essential to define this register during the programming phase for opening codes/badges.
Opening code The SKR has 100 memory slots for programming opening codes. According to the configuration of the keypad, you can programme codes containing 3 to 6 characters. The choice of the number of characters is applicable to all the codes.
Page 13
Example N° 1 - Registering a 5-character code, "A15B1" for activation in permanent validity with relay N°1. 1. Input "12345" (programming mode), 2. then “A15B1” (input opening code), 3. then “B” (saving code to memory), 4. & lastly "BB" (exit programming mode). Breakdown of button/reader stages in the example Button Reader...
Page 14
Example N° 3 - Registering 3-character codes "789" and "A0B", for temporary validity of 5 uses with relays N°1 and 2 (See configuration section to modify the number of characters) 1. Input "123" (programming mode), 2. then “B5” (select register B5), 3.
Page 15
Example N°4 - Registration of 5-character codes "56789" and "98765", with use of master badge for permanent validity 1. Present the master badge (programming mode), 2. input "B7" (select register B7), 3. then “0” (code management only), 4. then “56789” (input first opening code), 5.
Opening badge The SKR has 500 memory slots, N°001 to N°500, for programming opening badges. For each badge to be programmed, you need to define a memory slot. Only COMELIT badges are compatible with the keypad. (Badges authorize: SK9050B/A, SK9050G/A, SK9050GB/A, SK9050GG/A, SK9050GO/A, SK9050GR/A, SK9050GY/A, SK9050O/A, SK9050R/A, SK9050Y/A, SK9052.
Page 17
Example N°3 - Registration of a badge to memory slot "007" for relays N°1 & 2 and a badge to memory slot "114" for use with relay N°1 1. Present the master badge (programming mode), 2. input "B5" (select register B5), 3.
Page 18
Example N°4 - Registration of two badges to memory slots "001" and "002", with use of master code "12345", for use with relay N°1 1. Input "12345" (programming mode), 2. input "B7" (select register B7), 3. then "1" (badge or badge + code management), 4.
To reinforce the level of security the SKR keypad allows you to programme opening by use of a badge + code combination. Only COMELIT badges are compatible with the keypad.
Page 20
Example N°2 - Registration of 3 badges (memory slots 1 to 3) combined with the code "11111", for activation with relay N°1 1. Present the master badge (programming mode), 2. input "000" (code combination insertion mode), 3. then "11111" (input opening code), 4.
Deletion of one or several codes All the opening codes programmed in the SKR can be deleted individually, as a group or all at once. Notes: When you delete a code which is combined with one or more badges, you will also delete the badge or badges combined with the code in question.
Deletion of one or several badges All the opening codes programmed in the SKR can be deleted individually, as a group or all at once. Notes: When you delete a badge which is the only one to be combined with a certain code, you will also delete the code. If several badges are combined with a certain code only deletion of all the relevant badges will result in deletion of the code.
Timer – Operating mode – Buzzer relay: code [B1] & [B2] To define the timer settings for relays N°1 or N°2, respectively use registers B1 or B2. The two relays are have a default setting of 05 seconds. However, this value can be set to between 1 and 99 seconds. If you wish to use the relay in a two-state role, i.e.
According to the type of programming you wish to carry out (code only or badge & code), the value for this register must be in accordance with the method used to access the SKR's programming mode (master code or master badge).
» If the code is correct, the SKR will trigger the relevant relay, and the status of the indicator lights will change to a constant colour (green=relay N°1 - mauve=relay N°2 – white=relays 1 and 2). According to the settings defined, the relay will have a timer setting or will operate in bistable mode.
Register of programmed badges (example) The following table is an example which will allow you to keep a record of the first 100 memory registers (500 in total) for your keypad. Code if Code if RegisterN° Badge series N° Relay RegisterN°...
Maglock varistor CA/SKR/BP1 With electric lock 4399 If a maglock or an electric lock is used, make sure that the varistor provided with your keyboard is connected to prevent it from alfunctioning.
With clock and alarm 4399 Clock Relays When the alarm is triggered, the output is active for 1 minute. CA/SKR/OR Wiegand Connection 4399 Towards centre Wiegand Each time a button is pressed, its code will be emitted in 4 bits.
With external relays 4399 4399 4399 Unusable terminal Unusable terminal REL2 REL1 Unusable N°2 N°1 terminal Maglock Electric lock varistor varistor Maximum of two relays (Numbers 1 and 2) CA/SKR/R2...
Page 30
w w w . c o m e l i t g r o u p . c o m Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy...
Need help?
Do you have a question about the SKR and is the answer not in the manual?
Questions and answers