Page 2
The information provided in this document is for reference only. We do not assume any responsibility arising out of the application of the products. This manual is subject to change without any notice. RACK-2300, ICP are trademark of ICP Electronics Inc.
1.2 Product Specifications 1.3 Dimensions Chapter 2 System Setup 2.1 Front Panel of RACK-2300 2.2 LP-01 Control Panel of RACK-2300 2.3 Rear Panel of RACK-2300 2.4 Removing the chassis cover 2.5 Backplane Installation 2.6 Disk Drives Installation 2.7 Power Supply Installation...
Chapter 1 Product Information 1.1 General Information RACK-2300 IPC chassis is a rugged PC/AT compatible computer designed for the factory floor and other Industrial harsh environment. RACK-2300 features 2 slots Passive Backplanes and high reliability ACE-1010A series power supply. The chassis can easily be installed on 19" Rack or Desktop with the supplied brackets.
Chapter 2 Installation Procedure The following set up procedures are provided to assist you in installing the system unit, please follow the steps below: 2.1 Front Panel of RACK-2300 POWER SWITCH RESET SWITCH POWER LED BUZZER HDD LED...
2.3 Rear Panel of RACK-2300 AC INPUT 2.4 Removing the chassis cover The cover is mounted by eight screws on the top of the chassis, remove them and slide the cover to the rear of the chassis. Figure below shows how to...
2.5 Backplane Installation Figure below illustrates how to install the backplanes on the RACK-2300 PCI-2SD2 STEP1 STEP2 Please plug the connector of ACE-1010A to the Backplane IP-2SD2. ACE-1010A POWER SUPPLY BACKPLANE:PCI-2SD2...
2.6 Disk Drives Installation 1. Open the upper disk drive cover. 2. Mount the drive rails on the side of FDD 3. Attach the FDD to the bracket with four screws and connect FDD cable & power cable to the FDD. 4.
APPENDIX C Power Supply REFERENCE DOCUMENTS The subject power supply will meet the EMI requirements and obtain main safety approvals as following: - FCC Part 15 Subpart J, Class ‘B’ 115 Vac operation. - CISPR 22 Class ‘B’ 230 Vac operation. SAFETY - NEMKO EN 60950 - TUV EN60950 OR VDE EN60950...
Page 16
The +3.3V and +5V total output shall not exceed 100watts, and the total output for this subject power supply is 170 watts. Ripple and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency.
Page 17
OUTPUT TRANSIENT LOAD RESPONSE +5V vdc: 16.0 amps 12.0 amps Volts variation: 400 mV max (p-p) Setting time: ms max +12V vdc: 5.0 amps 3.75 amps Volts variation: 450 mV max (p-p) Setting time: ms max ...
Page 18
Energy Star 115VAC @min Load 56% minimum In the low-power Energy Star state, the AC input power is limited to 30W. ENVIRONMENTAL REQUIREMENTS The power supply will be compliant with each item in this specification for the following Environmental conditions. TEMPERATURE RANGE Operating 0 to +40 deg.
Need help?
Do you have a question about the RACK-2300 and is the answer not in the manual?
Questions and answers