Do you have a question about the Eco-Quartz and is the answer not in the manual?
Questions and answers
Summary of Contents for Smokin Solutions Eco-Quartz
Page 1
Fault Finding Eco-Quartz Heater Fault Reason Check Repair The lights and Power is not Mains plug is not Reconnect plug heater do not connected connected work Fuse in plug is Replace fuse (13A) blown The heater Tube is faulty Tube is correctly...
Page 2
• Carefully replace the lid, ensuring that the ensure that the wa- terproof seal is still fitted in its groove and that the PIR is CONTENTS pointing in the correct direction • Fit and tighten the screws. To link more than one heater to a remote control follow procedure B for each heater in turn..
Page 3
Programming Unpacking ! DANGER ! Please unpack and check the contents of the box before proceeding ! MAINS VOLTAGE IS PRESENT ON MANY ! with the installation. The box should contain the following parts: ! COMPONENTS ON THE ! ! HEATER CONTROL CIRCUIT BOARD ! The heater remote control handset supplied is already programmed to operate the heater.
Page 4
The Eco-Quartz heater warms people and not the air by radiant • To refit the glass, locate it between the bosses on the lid. Make infrared heat. This form of heat, like the sun, is unaffected by wind sure that it is fitted the right way up so that the logo appears and other weather conditions.
Page 5
WARNING: THIS APPLIANCE MUST BE EARTHED • Wipe the surface of the bulb with a clean lint-free cloth. IMPORTANT: Fitting a different plug: • Close the heater as described previously. The wires in the mains lead are coloured in accordance with the Change the heating element following code: •...
Page 6
Installation Maintenance & Cleaning For safety purposes, it is recommended that the heater bracket Disconnect from the mains supply and allow to cool be mounted a minimum of 2.75 metres above the floor. before attempting to clean or maintain the heater unit. Place the wall part of the mounting bracket against the wall in the desired position and mark the location of the 4 fixing holes.
Page 7
Wiring • If the ambient temperature is less than 15°C The heater will only operate if a person moves within the Warning: This appliance must be earthed reception range of the PIR detector mounted below the heater. The heater will switch on at full power for 4½ All heaters are supplied as standard with 4 metres of cable and a •...
Page 8
Adjustment Operation During normal operating conditions the outside of the heater, There are no user adjustments inside the heater. especially the glass, reaches a high temperature. Any adjustments should only be made with the power disconnected Please ensure that you have read and adhere to the and the heater allowed to cool down if it has previously been Wiring section on page 6 in use...