11-30 & 11-100 Manual & Installation Function Thermal Layering Thanks to its design and control features, the Laddomat 11 means optimal thermal layering in storage tanks, with a low and even charging flow. This layering system is benefi cial as it increases storage capacity.
Page 3
On, for example, pellet burners the pump can be started and stopped at the same time as the burner. Image 4 Shut off valves are installed to facilitate servicing. Laddomat 11 should be placed low to avoid keeping the valve hot. Image 2 Image 5 Image 6 The installation position does not affect the function of the valve.
Page 4
5839 63°C 11 00 63 8222 87°C 11 00 87 1240 66°C 11 00 66 Installation & setting pump Laddomat LMXA Image 2 Blue Green Yellow Blue The cartridge is easily replaced by unscrewing the cap. The cartridge is Inductor...