Function
Thermal Layering
Thanks to its design and control features, the Laddomat 11
means optimal thermal layering in storage tanks, with a low
and even charging flow. This layering system is benefi cial as
it increases storage capacity.
START UP PHASE
Laddomat 11-30
M = Mixed
Flow
Laddomat 11-100
Automatic Heating reserves the right to change specifications without notice.
2
®
Laddomat
Mixing valves for solid fuel boilers
®
11-30 & 11-100 Manual & Installation
OPERATING PHASE
M = Mixed return
flow to bottom of
heat source
Pump placement
and flow direction,
to bottom of heat
source
H = Hot flow
C = Cold Flow
H = Hot flow
C = Cold Flow
M = Mixed Flow
H = Hot flow from
top of heat source
C = Cold
return flow

Technical Data

Thermostat cartridge:
45°, 53°, 57°, 63°, 66°, 72°, 78°, 83° or 87°C
Pressure class:
PN 6
Max. temp:
Max +100°C
Min +5°C
Laddomat 11-30:
Pump:
4 m
Connection:
3 x Cu22 or 3 x R25
Max. boiler output:
30 kW
Kvs-value:
3,4 m³/h
Laddomat 11-100:
Pump:
4 m, < 35 kW
Connection:
6 m, < 65 kW
Max boiler output:
7 m, < 120 kW
Kvs-value:
3 x Cu28 or 3 x R32
120 kW (see pump above)
14 m³/h
FINAL PHASE