Installationsanleitung
Installation guide
Instructions d'installation
29 30 31 32 33 34
M-Bus
USB/LAN
RS232/Rep
Modem
Rx/Tx
1 2 3 4 5 6
Diese
Anleitung ist
dem Endkunden
auszuhändigen.
This guide must
be given to the end
consumer.
Ce guide doit être
donné au client
final.
Français
IZAR
CENTER 250
M e m o r y

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Izar Center and is the answer not in the manual?

Questions and answers

Summary of Contents for Diehl Izar Center

  • Page 1 Deutsch English Français IZAR CENTER Installationsanleitung Installation guide Instructions d’installation 29 30 31 32 33 34 IZAR M-Bus CENTER 250 USB/LAN M e m o r y RS232/Rep Modem Rx/Tx 1 2 3 4 5 6 Diese Anleitung ist dem Endkunden auszuhändigen.
  • Page 2 Deutsch English Français IZAR CENTER 29 30 31 32 33 34 IZAR M-Bus CENTER 250 USB/LAN M e m o r y RS232/Rep Modem Rx/Tx 1 2 3 4 5 6 29 30 31 32 33 34 IZAR M-Bus CENTER 250...
  • Page 3: Allgemeines Zur Anleitung

    Schnittstellenkabel RS232 (female) ƒ USB Kabel Beschreibung Der IZAR CENTER schickt eine Anfrage an die am M-Bus angeschlossenen Zähler. Diese Aktion kann manuell durch den Benutzer oder automatisch durch den IZAR CENTER ausgeführt werden. Zur automatischen Zählerauslesung wird ein IZAR CENTER mit Memory benötigt, in den ein allgemeines oder zähler-...
  • Page 4: Technische Daten

    English Français Deutsch IZAR CENTER Technische Daten Bezeichnung Wert Spannungsversorgung 110 ... 230 V AC Frequenz 50 ... 60 Hz Gehäuse Hutschienengehäuse mit Sicherungsautomatenprofil aus wärmebeständigem Kunststoff (ABS) Schutzklasse IP 20 Schnittstellen USB, Ethernet LAN, RS232 (für PC, Modem), M-Bus...
  • Page 5: Montage / Demontage

    Vorschriften erfolgt, entbindet Diehl Metering von jeglicher Verantwor- tung. Diese liegt ausschließlich beim Verursacher. Der IZAR CENTER darf nur von Fachkräften mon- tiert und in Betrieb genommen werden. Montage / Demontage Vor jeder Montage oder Demontage muss die Stromzuführung (Buchse 16, Abb.
  • Page 6 Strecken oder zwischen Gebäuden ist die Zwischenschaltung eines Blitzschutzes erforder- lich. Folgende Typen sind hierfür qualifiziert. M-Bus Verbindungen: ƒ Dehn BXT und Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-Nr. 3055664 LAN Verbindungen: ƒ Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-Nr. 3055635 Die Stromversorgung muss nicht unterbrochen werden, um M-Bus Geräte am IZAR CENTER...
  • Page 7 Zähler verbunden werden. Alle M-Bus Ausgänge sind par- allel geschaltet. Repeater ƒ M-Bus Ausgang eines weiteren IZAR CENTERs an die Klemmen 1 und 2 anschließen. Verbinden Sie die Klemme 5 oder 6 mit einen Schutzerdepotential. Schutzerde muss am IZAR CENTER angeschlos- sen sein. - 7 -...
  • Page 8 100 ... 130 % Buslast (Warnung) Die maximale M-Bus Leistung ist erreicht. Schließen sie keine weiteren M-Bus Zäh- ler mehr an. In diesem Zustand ist der IZAR CENTER noch voll funktionsfähig Überlast In diesem Fall sind entweder zu viele M-Bus Zähler angeschlossen, oder die Busleitun- gen haben einen Kurzschluss.
  • Page 9: Zulassung Und Konformität

    Das Gerät darf nicht mit dem Hausmüll entsorgt werden. Senden Sie es zum Recycling an den Hersteller zurück. 10. Zulassung und Konformität Hiermit erklärt Diehl Metering, dass sich das IZAR CENTER in Übereinstimmung mit den grundlegenden Anforderun- gen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet.
  • Page 10: Package Content

    ƒ USB cable Description The IZAR CENTER sends a request to the meters con- nected to the M-Bus. This action can be performed man- ually by the user or automatically by the IZAR CENTER. For the automatic meter reading a IZAR CENTER with memory is required, where a general or meter individ- ual reading interval is programmed.
  • Page 11 Deutsch Français English IZAR CENTER Technical data Designation Value Power supply 110 ... 230 V AC Frequency 50 ... 60 Hz Housing Top hat rail housing with circuit breaker profile from heat-resistant plastic (ABS) Protection class IP 20 Interface USB, Ethernet LAN, RS232...
  • Page 12: Installation / Removal

    Before every installation or removal the power supply (socket 16, fig. I) must be interrupted. Install IZAR CENTER ƒ Snap the IZAR CENTER onto the hat rail. The black safety catch (socket 65, fig. I) must point downwards and engage audibly. Remove IZAR CENTER ƒ...
  • Page 13 The following types are qualified for this purpose. M-Bus connections: ƒ Dehn BXT and Dehn module BXT ML2 BD S48, Diehl Metering art. no. 3055664 LAN connections: ƒ Dehn DPA M CAT6 RJ45 S48, Diehl Metering art. no.
  • Page 14 M-Bus meter. All the M-Bus outputs are connected in parallel. Repeater ƒ Connect M-Bus output of a further IZAR CENTER to the terminals 1 and 2. Connect terminal 5 or 6 with a protective ground potential.
  • Page 15: Display Elements

    IZAR CENTER ƒ Use the supplied USB cable (maximum cable length 3 m). (Connection example see fig. II.) Display elements Five LEDs on the front side of the IZAR CENTER show the corresponding operational conditions. M-Bus Display Operational condition green 0 ...
  • Page 16: Environmental Note

    CENTER conforms to the basic requirements and all other relevant regulations of the directive 1999/5/EG. The full declaration of conformity is available at http://www.diehl.com/en/diehl-metering/products- solutions/product-download/ On this page, please select "Diehl Metering GmbH" from the partner list and "Metering Systems" from the product list. - 16 -...
  • Page 17: Contenu De L'emballage

    Câble d'interface RS232 (femelle) ƒ Câble USB Description IZAR CENTER envoie une requête aux compteurs connectés au M-Bus. Cette action peut être exécutée manuellement par l'utilisateur ou automatiquement par l'IZAR CENTER. Pour un relevé du compteur automatique il faut disposer d'un IZAR CENTER avec mémoire, dans laquelle l'intervalle...
  • Page 18: Caractéristiques Techniques

    Deutsch English Français IZAR CENTER Caractéristiques techniques Désignation Valeur Alimentation électrique 110 ... 230 V AC Fréquence 50 ... 60 Hz Boîtier Boîtier du rail DIN avec disjoncteur automatique en plastique résistant à la cha- leur (ABS). Classe de protection...
  • Page 19: Montage / Démontage

    Montage de IZAR CENTER ƒ Clipser l'IZAR CENTER sur le rail DIN. Le crochet de fixation noir (prise 65, fig. I) doit montrer vers le bas et l'encliquetage doit être audible. Démontage de IZAR CENTER ƒ...
  • Page 20 Nous avons qualifié les prochains types : M-Bus connections : ƒ Dehn BXT et Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-No. 3055664 LAN connections: ƒ Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-No.
  • Page 21 + et une sortie - pour chaque compteur M-Bus. Toutes les sorties M-Bus sont en parallèle. Répéteur ƒ Connecter la sortie M-Bus d'un autre IZAR CENTER aux bornes 1 et 2. Connecter la Terre à la borne 5 ou 6. La Terre doit être connectée à IZAR CENTER.
  • Page 22: Eléments D'affichage

    Deutsch English Français IZAR CENTER Eléments d'affichage Les états de fonctionnement sont indiqués par cinq LED sur la face avant de IZAR CENTER. M-Bus Affichage Etat de fonctionnement vert 0 ... 100 ...charge du bus jaune 100 ... 130 %...charge du bus (avertisse-...
  • Page 23 IZAR CENTER correspond aux exigences principales et aux autres prescriptions correspondantes de la directive 1999/5/EC. La déclaration CE de conformité complète est disponible http://www.diehl.com/fr/diehl-metering/produits- solutions/documentation-a-telecharger/ Veuillez sélectionner le partenaire « Diehl Metering GmbH » et la rubrique « Systèmes ». - 23 -...
  • Page 24 Diehl Metering GmbH Industriestrasse 13 91522 Ansbach Phone: +49 981 1806-0 Fax: +49 981 1806-615 info-dmde@diehl.com www.diehl.com/metering...