Jet-Master Safety instructions Caution! The directions in this manual must be followed strictly. The safety instructions and the manual must completely be read and understood before start-up! The device may only be operated under the constant supervision of trained personnel. Maintenance of the device may only be carried out by the manufacturer.
Page 3
Sufficient safety distance, especially to personnel, must be considered when assembling the device. Performers and participants must be clear of the safety distances beforehand, and the operation must be rehearsed. In dangerous situations the device must immediately be shut down! The sideway safety distance in still air is 2 m.
Page 4
Use only original parts from the manufacturer for extension or replacement of the high-pressure hoses. Other hoses are generally unsuitable; their use may result in considerable hazard for persons and/or property. The unit may only be run with CO from pressure cylinders with a riser pipe.
Page 5
Jet-Master Operating manual 1. Note: please read and follow the safety instructions closely! 2. Preface The Jet-Master is designed to create quickly dissolving fog columns with a height of up to 5m, it is run with pressurized CO gas. The device is basically designed for in-door use;...
Page 6
5. Installation of the unit with the multicontroller or the 8 channel DMX controller Only original parts from the manufacturer may be used for the installation. The Jet-Master works with highly compressed CO gas, which becomes extremely cold when it evaporates (-70°C). All parts of the unit are specifically designed and selected by the manufacturer and must neither be changed nor replaced with other parts.
Page 7
7. In case of emergency If serious malfunctions occur that pose a threat to persons and property, the device must immediately be shut down. Unplug the power cable. Then immediately close the hand valve of the CO pressure cylinder. 8. Care, maintenance and storage The unit is mostly maintenance-free.
Page 8
1.5% : increase of breathing time volume of more than 40% 4%: exhaled breathing air 5%: appearance of headaches, dizziness and unconsciousness 8%: unconsciousness; suffocation after 30-60 minutes TBF-PyroTec GmbH Lichterfelder Str. 5 A 21502 Geesthacht Tel.: + 49 (0)4152 157 9950...