  • Page 2 DUOPELET, KLIMOSZ UNIPELET requires regulation by the authorized service. Boilers KLIMOSZ UNI PELET requires montage of the steel jackets and the fuel tank. Technical Data for KLIMOSZ DUOPELET Tab. 1. Technical parameters of the KLIMOSZ DUOPELET NG 15 – 45 and DUOPELET B 15 - 35. KLIMOSZ KLIMOSZ...
  • Page 3 Tab. 2. Technical parameters of the KLIMOSZ DUOPELET NG. KLIMOSZ KLIMOSZ KLIMOSZ KLIMOSZ Parameter DUOPELET DUOPELET DUOPELET DUOPELET AUTOMATIC MODE Nominal power – pellets (max / nominal) 50 / 47 75 / 62 97 / 90 140 / 120 Efficiency - pellets...
  • Page 4 • ash content • ATTENTION!!! The KLIMOSZ heating boilers are not intended for burning waste and no substances other than those recommended by the manufacturer can be burnt in them. Tab.4. Recommended fuel for burning in automatic mode. Main Fuel...
  • Page 5 KLIMOSZ DUO PELLES NG 15 ÷ 75 boilers can be installed in a closed system. KLIMOSZ DUO PELLES NG 100 ÷ 150 and KLIMOSZ DUOPELET B 15 ÷ 35 boilers can be installed only in a open system. In the lower chamber there is situated the automatic burner to combust pellets.
  • Page 6: Boiler Dimensions

    1144 2205 1555 1285 1144 2205 1555 1285 1144 2540 1826 1582 1450 2540 1020 1826 1582 1450 1220 1950 1200 1755 1450 1340 1950 1200 1755 1450 Fig. 1. Dimensions KLIMOSZ DUOPELET NG boilers.. Operation and installation manual 2015.12.07...
  • Page 7 Fig. 3 The heights to flue derived up are given below on the boiler KLIMOSZ DUO PELETS Klimosz Duo 15 - 1260 mm Klimosz Duo 55 ÷ 75 - 1760 mm Klimosz Duo 25 ÷ 45 - 1420 mm Klimosz Duo 100 ÷ 150 - 1920 mm Operation and installation manual 2015.12.07...
  • Page 8 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1075 1135 272,5 2723 1171 1135 272,5 2723 1267 1135 272,5 2723 1363 1053 1135 272,5 2723 Fig. 4. Dimensions KLIMOSZ UNIPELET boilers.. Operation and installation manual 2015.12.07...
  • Page 9 Dimensions of the additional combustion chamber [mm] [mm] [mm] 45,4 DUOPELET 15 DUOPELET 25 48,7 58,2 DUOPELET 35 DUOPELET 45 75,4 92,7 DUOPELET 55 DUOPELET 75 122,1 DUOPELET 100 1070 DUOPELET 150 UNIPELET 15 UNIPELET 25 UNIPELET 35 Fig.5. Dimensions of the additional combustion chamber.
  • Page 10 1. Burner grate; 2. Whole for the burner sensor; 4. Mounting wholes of the burner; 5. Ventilator. Fig. 9. Pellets burner trough – KLIMOSZ DUOPELET B 1. Cast iron grate; 2. Whole for the burner sensor;...
  • Page 11 Installation of the fire-resistant catalyst The ceramic catalyst in KLIMOSZ DUOPELET and KLIMOSZ UNIPELET boilers consists of rectangular plates. The plates should be put on shelves above the retort burner through the lower door of the ash pan.
  • Page 12 Jacket assembly in KLIMOSZ UNIPELET boiler Fig. 11 Installation of the boiler heat exchanger housing for KLIMOSZ UNIPELET. Front section U 22C Middle section with a strip Rear section Plug Insert Anchor bolt Sealing Clack valve thermomanometer Thermostat well 6.2 Burner maintanance procedure User should control the burner to receive the correct work.
  • Page 13 Boilers KLIMOSZ DUOPELET and KLIMOSZ UNIPELET have the additional Chambers to combust the solid fuel in manual mode. The burning proces Has palce on the steel or cast iron grate. In case of Klimosz Unipelet boiler to strt off the manual combustioning, pellets burner should be desmounted with the ceramic plates.
  • Page 14 In the evening, before burning in the boiler during the night, the grate should be cleaned thoroughly. In the morning, after night burning, remove caked coal with a hook to clear the air supply. Put some fuel onto the embers and do not remove ash and caked fuel from the grate until the fuel is burning.