Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, and Hurricane 1302 are registered trademarks or trademarks of Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
• Do not use for space heating purposes. • Use only CHAUVET DJ water-based fog fluid. • Drain the tank before transporting the product. • Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated in the decal or rear panel of the product.
230 V Version Power Switch Low Fluid Indicator Manual Fog Button Fuse Holder Power In Remote Connection Fluid Level indicator Fog Fluid Line Fluid Tank Safety Loop Carrying Handle Fog Output Nozzle Hurricane 1302 User Manual Rev. 1 Page 3 of 11...
3. Setup AC Power The Hurricane 1302 has a fixed voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
Floor Mounting (x4) While operating the Hurricane 1302, make sure there is adequate fog fluid in the machine to prevent pump and heater damage. When the fog fluid level becomes low, simply add more fog fluid to continue using the Hurricane 1302.
4. Operation Remote or Manual Operation The Hurricane 1302 can be operated manually, or with the included timer remote controller (FC-T). The Manual button is located on the rear of the unit. See the product Overview. Two other optional remote controls are also available: a manual wired remote (FC-M) and a wireless remote (FC-W).
When pressed, the Manual Fog Button on the Hurricane 1302 will override the FC-T. Fluid Tank Indicator LED The indicator LED on the back of the Hurricane 1302 shows the status of the fogger, as follows: • Orange-pump is not detecting fluid.
Do Not operate the machine without fluid at any time. Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane 1302. Make sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of your product.
Release manual fog button, and press it again to noise engaged reset pump protection system. If you still experience problems after trying the solutions presented here, contact Chauvet Technical Support. Hurricane 1302 User Manual Rev. 1 Page 9 of 11...
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended. Chauvet reserves the right to use its own discretion to repair or replace returned product(s). Hurricane 1302 User Manual Rev. 1 Page 11 of 11...
Voice: +52 (728) 285-5000 www.chauvet.com.mx Visit the applicable website above to verify our contact details and instructions to request support.Outside the U.S., United Kingdom, Ireland, Mexico or Benelux, contact the dealer of record. Page 12 of 11 Hurricane 1302 User Manual Rev. 1...