Download Print this page

Nitronic HRC3070 Operating Instructions Manual

Hardness measuring

Advertisement

Quick Links

Nitronic AG
Nitronic
AG
Nitronic
Nitronic
AG
AG
Mattenstrasse 11
CH – 2555 Brügg
Tel.
Switzerland
Fax
+41 32 373 70 70
+41 32 373 70 75
Hardness Measuring
Hardness Measuring
Hardness Measuring
Hardness Measuring
Device HRC3070
Device
Device
Device
Operating Instructions
Operating Instructions
Operating Instructions
Operating Instructions
Please read these instructions carefully, before operating.
HRC3070
HRC3070
HRC3070
Edition V2.0

Advertisement

loading

Summary of Contents for Nitronic HRC3070

  • Page 1 Mattenstrasse 11 CH – 2555 Brügg Tel. +41 32 373 70 70 Switzerland +41 32 373 70 75 Hardness Measuring Hardness Measuring Hardness Measuring Hardness Measuring Device HRC3070 Device HRC3070 Device Device HRC3070 HRC3070 Operating Instructions Operating Instructions Operating Instructions Operating Instructions Edition V2.0...
  • Page 2: Table Of Contents

    Nitronic HRC 3070 Nitronic HRC 3070 Nitronic HRC 3070 Nitronic HRC 3070. We accept no responsibility for consequential damages. Contents Contents Contents Contents General ................2...
  • Page 3: Product Description

    • Suitable for metallic materials • For workpieces that are heavy or already fitted Commissioning Commissioning Commissioning Commissioning When using the Nitronic Nitronic Nitronic HRC 3070 Nitronic HRC 3070 HRC 3070 HRC 3070 for the first time or after an extended period of non-use (longer than three months) insert batteries according to the polarity indicated.
  • Page 4: Operation

    Fig. 3 Loading the HRC3070 • Place the Nitronic HRC 3070 Nitronic HRC 3070 Nitronic HRC 3070 with the tip (3) on the material to be tested and press down on lock (2) to Nitronic HRC 3070 trigger the impact (Fig. 4).
  • Page 5: Working Area

    +41 32 373 70 70 Switzerland +41 32 373 70 75 Working area Working area Working area Working area In order to obtain very precise measurements, the Nitronic Nitronic Nitronic HRC 3070 Nitronic HRC 3070 HRC 3070 must be kept completely still HRC 3070 during the triggering process.
  • Page 6: Device Faults

    Nitronic AG Nitronic Nitronic Nitronic Mattenstrasse 11 CH – 2555 Brügg Tel. +41 32 373 70 70 Switzerland +41 32 373 70 75 Device faults Malfunction Malfunction Malfunction Malfunction Diagnosis Diagnosis Diagnosis Diagnosis Remedy Remedy Remedy Remedy False measurement Bearing surface (3) pitted, dirty or Protect bearing surface from damage.
  • Page 7: Replacement Parts, Options

    Nitronic AG Nitronic Nitronic Nitronic Mattenstrasse 11 CH – 2555 Brügg Tel. +41 32 373 70 70 Switzerland +41 32 373 70 75 Replacement parts Replacement parts Replacement parts Replacement parts, , , , o o o o ption ption...