  • Page 1 USER'S MANUAL THERAPY_AIR_ION_MANUAL_EN.indd 1 THERAPY_AIR_ION_MANUAL_EN.indd 1 17-01-2008 10:35:29 17-01-2008 10:35:29...
  • Page 2: Table Of Contents

    DEAR CUSTOMERS First of all, we would like to thank you for purchasing a ZEPTER air cleaner. This product is superior to existing air cleaners, guaranteeing clean and healthy air. For optimal use and maintenance, please read this User’s Manual carefully and retain the warranty. This User’...
  • Page 3: Safety Information

    fi re. Do not use the appliance if the power cord is damaged as you may suffer an electric shock or cause a fi re. Ask Zepter Repair Service to replace the cord. THERAPY_AIR_ION_MANUAL_EN.indd 4-5 THERAPY_AIR_ION_MANUAL_EN.indd 4-5...
  • Page 4 If the appliance emits unusual noises or smells, candles, cigarettes or other infl ammable objects on the immediately switch it off and ring Zepter Repair appliance as you may suffer an electric shock or cause Service as there is a risk of fi re.
  • Page 5 SAFETY INFORMATION Do not insert your fi ngers or any other objects into the Do not attempt to repair, disassemble or modify the air inlets or outlets as you may suffer an electric shock appliance as you may suffer an electric shock or cause or cause a fi...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS 2.1 FEATURES Excellent Air Purifi cation Wall-Hanging Various fi lters, including a HEPA fi lter coated with an Slim Design (Option) organic anti-bacterial material (Thiabendazole Type) and The slim design makes the unit suitable for wall hanging. anti-mould substances, have been designed and installed to remove indoor pollutants in an instant.
  • Page 7: Components

    OPERATING INSTRUCTIONS 2.2 COMPONENTS FRONT REMOTE CONTROL MOOD LIGHT POWER SPEED MODE LIGHT OPERATION PART/ INDICATION PART PARTICLE SENSOR BATTERY (AAA SIZE) LIGHT SENSOR (illumination sensor) POLLUTION DEGREE LIGHT REAR HANDLE POWER CORD UNIT HENGER VENTILATING GRILLE THERAPY_AIR_ION_MANUAL_EN.indd 12-13 THERAPY_AIR_ION_MANUAL_EN.indd 12-13 17-01-2008 10:35:55 17-01-2008 10:35:55...
  • Page 8: Operating Components

    OPERATING INSTRUCTIONS 2.3 OPERATING COMPONENTS 2.4 INDICATION COMPONENTS Indicators (lights) enable you to follow and control the appliance’s functions. Air fl ow speed indicator (Speed Light) The air fl ow speed is set automatically in the automatic mode/children’s mode in positions 1 to 4, depending on the level of air pollution.
  • Page 9: Internal Filters

    OPERATING INSTRUCTIONS 2.5 INTERNAL FILTERS NEGATIVE ION A negative ion generator produces a vast quantity of negative ions, letting you enjoy really fresh air. FILTER CASE Pre-Electrostatic, Medium, HEPA, AG Allergy, AC Deodorant fi lters are installed.. ANTISTATIC FILTER (Pre-Electrostatic Filter) removes large particles of dust, mould, hairs, dandruff, pet hairs, etc.
  • Page 10: Preparation

    OPERATING INSTRUCTIONS 2.6 PREPARATION 3. Fix the frame fi rst at the bottom of the appliance and then at the top. Put the front cover back into place on the appliance. This appliance is strictly intended for use in closed rooms. The Antibacterial fi...
  • Page 11: Cleaning

    OPERATING INSTRUCTIONS 2. Press the button to start the appliance. After you turn it on, the appliance will Air pollution sensor initially operate automatically and then in the last mode selected. The air quality sensor is set at standard sensitivity. You may have to adjust the 3.
  • Page 12 OPERATING INSTRUCTIONS ✔ Cleaning the particle sensor 1. Press the light button and hold for 2 seconds. 2. The light indicator is activated. (once every two months) 3. Quiet night mode. • Open the cover of the particle sensor on the 4.
  • Page 13: Filter Replacement

    OPERATING INSTRUCTIONS Cleaning the pre-electrostatic fi lter (once every 2-4 weeks) 1. Pull the lower end of the front cover to separate it from the appliance. 2. Pull the fi lter out by the handle. 3. Use a steam cleaner to dust the fi lter. 4.
  • Page 14 OPERATING INSTRUCTIONS Changing the AC deodorant (activated-carbon) fi lter Mounting the appliance on a wall (optional) (once every 12 - 24 months) If you wish to mount Therapy Air Ion on the wall, make sure that the appliance is positioned at the recommended distance from the walls and ceiling (see the picture).
  • Page 15: Troubleshooting Tips

    3. Technical data* Product code and name PWC-570 If problems occur when trying to operate the appliance, make sure that you have followed the Instructions for Use correctly. Before you ring Zepter Repair Service for Model AP-1004AHZPT help, please check the following.
  • Page 16: Customer Service

    CUSTOMER SERVICE WARRANTY INFORMATION & SPECIFICATIONS GUARANTEE P R O D U C T W A R R A N T Y Please fi ll in the blanks and save this in order to request service. All our appliances have undergone strict inspection tests and are guaranteed CUSTOMER INFORMATION against manufacturing defects.