Advertisement

I Product Intro............................................................................................................2
II General Safety Rules ............................................................................................ 2
III Major Functions .....................................................................................................2
IV Operation Precautions ...............................................................................................3
V General Inspection.................................................................................................... 3
VI Functional Inspections.............................................................................................................................. 3
VII Battery Recharging Instruction..................................................................................3
VIII Firmware Upgrades.....................................................................................3
IX Product Familiarization........................................................................................... 5
1. Interface and Buttons..........................................................................................5
2. Screen............................................................................................................5
X Measurement Operation Instruction............................................................................6
1. Parameter Area Intro.............................................................................................6
2. Measurement Area Intro.................................................................................6
3. Specific Parameters Intro.................................................................................6
XI Application Examples...........................................................................................11
1. Example One: Measure Simple Signal.....................................................................11
2. Example Two: Measure with Cursor........................................................................12
3. Example Three: Save Waveform Image.....................................................................13
4. Example Four: Acquire Single Signal........................................................................14
5. Example Five: Compare Waveform Signals...............................................................15
DSO Nano V3 User's Manual
Contents

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSO Nano V3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seeed DSO Nano V3

  • Page 1: Table Of Contents

    DSO Nano V3 User’s Manual Contents I Product Intro………………………………………………………………………………………..…….2 II General Safety Rules ……………………………………………………………………………….. 2 III Major Functions ………………………………………………………………………………………..2 IV Operation Precautions …………………………………………………………………………………..3 V General Inspection………………………………………………………………………………………. 3 VI Functional Inspections..........................3 VII Battery Recharging Instruction……………………………………………………………………….3 VIII Firmware Upgrades………………………………………………………………………….3 IX Product Familiarization………………………………………………………………………………. 5 1.
  • Page 2: I Product Intro

    I Product Intro DSO Nano pocket size oscilloscope is a compatible 32bit digital storage oscilloscope. Based on ARM Cortex -M3, it’s equipped with 320*240 color display, USB port and recharging function. It’s compact, simple to operate; meets the basic demands of school lab, electric furniture repairmen and electric engineering. II General Safety Rules To ensure your safety &...
  • Page 3: Operation Precautions

    IV Operation Precautions ▌Temperature: Working condition:+0℃ to +500℃ Non-working condition:-20℃ to +60℃: ▌Humidity: Working condition:High temperature:40° C - 50° C,0%-60%RH Working condition:Low temperature:0° C - 40° C,10%-90%RH Non-working condition:High temperature:40° C- 60° C,5%-60%RH Non-working condition:Low temperature:0° C - 40° C,5%-90%RH V General Inspection When you get a new DSO Nano, it’s suggested to inspect the product by the following steps: 1.Inspect for damage caused by shipping.
  • Page 4 1. Copy file from PC to virtual USB disk 2. After extension changes from “hex”to “rdy”,it is upgraded.
  • Page 5: Product Familiarization

    IX Product Familiarization 1. Interface & Buttons 2. Screen The screen display is depicted as below: Parameter Area Measurement Area Parameter Area Display the position of current waveform The table below shows the intro of button functions...
  • Page 6: Measurement Operation Instruction

    Button Function Run/Hold Choose to save current file ▲ Upward selection ▼ Downward selection ◄ (left/decrease)change setting parameters ► (right/increase)change setting parameters Menu Choose to save current parameter setting NOTE:There are corresponding colors for items in Parameter Area and Measurement Area. X Measurement Operation Instruction 1.
  • Page 7 Y Ranges Y-axis voltage per grid ProbeAtt Multiple FitRange Auto adjustment Y Offset Waveform adjusts up & down within the window CursorV1 Cursor V1:top limit of visible trigger level CursorV2 CursorV2:bottom limit of visible trigger level CursorTp Hide/ Display Measurement Cursor (2)Annotations of Xn Parameters...
  • Page 8 TimeBase X-axis voltage per grid Fit Base Auto adjustment ViewPosi Horizontal movement to view waveform SmplDpth Internal storage depth(1k~6k) CursorT1 Time measurement cursorT1 CursorT2 Time measurement cursorT2 CursorTp Hide/Display Measurement Cursor (3)Annotations of Tr parameters Choices of Triggering Mode SyncMode AUTO/NORM/SINGL/NONE Automation/Normal/Singular TrigMode...
  • Page 9 Freq Signal Frequency Duty Duty factor Vrms Voltage Effective Value Vavg Average Value of Voltage Vp-p Peak-to-Peak Voltage Vmax Maximum Voltage Vmin Minimum Voltage (5)Annotations of Ex Parameters Ext Refn 2 waveforms operation (Inp is current waveform; D/Data is previously saved waveform) -Inp/Data/-Data/Inp+D/D-Inp/Inp-D/Off Ext Posi Display current waveform...
  • Page 10 (6)Annotations of Fn Parameters Save Bmp Save bmp file (waveform image) to the built-in U disk Save Dat Save dat file to the built-in U disk Save Buf Save buf file (sampling buffering data) to built-in U disk Save Csv Save csv file (export sampling buffering data)to built-in U disk Load Dat load Dat...
  • Page 11: Application Examples

    (8)Annotations of Ca Parameters Cal Zero Calibration without voltage Oscilloscope Calibration:Press A CalRange Calibration with voltage Restore Master Reset XI Application Examples 1. Example One: Measure Simple Signal Observe one unknown signal in a circuit, quickly measure & display the signal’s frequency & peak-to-peak value. Please operate according to following steps: Connect the channel probe to the detection point of the circuit.
  • Page 12: Example Two: Measure With Cursor

    parameters that need analysis, e.g. Freq(frequency), Duty(dutyfactor), Vpp(peak-to-peak voltage)etc., the measured value will be displayed at the lower right corner of the screen, as shown in the image below: 2. Example Two: Measure with Cursor Measured value A cursor can be used to measure the time and voltage of the waveform very quickly. (1)Measure the cycle of signal source Please operate according to the following steps: Use...
  • Page 13: Example Three: Save Waveform Image

    (2)Measure peak-to-peak value of the signal source. Please operate according to following steps: Use “▲” or “▼” to choose Yn items in Measurement Area Press “OK” Use “▲” or “▼” to choose CursorV1 Use “◄” or “►” to adjust the position of CursorV1 to the crest Use “▲”...
  • Page 14: Example Four: Acquire Single Signal

    4. Example Four: Acquire Single Signal It’s the superiority and feature of digital oscilloscope to easily aquire non-periodic signals like impulsion and sentus. To aquire a single signal, you need a priori knowledge of it to set trigger level & trigger edge. E.g. if impulsion is a TTL PWL logic signal, trig level should be set as 2V, trig edge as rising edge trig.
  • Page 15: Example Five: Compare Waveform Signals

    5. Example Five: Compare waveform signals Please operate according to following steps: Input standard signal waveform to the channel, chose Data in EX, and then choose Save001.DAT to save the waveform, as shown in the image below. Input unknown to-be-measured signal to the channel, choose Fn →...