® TMP040 / TMP070 Heat Link 3-Way Mixing Panel Installation, Operation, and Maintenance Manual WARNING!!! Consult Manual Before Use HeatLink Group Inc. 4603E - 13th Street NE AVERTISSEMENT!!! Calgary, Alberta, Canada Consulter le T2E 6M3 manual avant l’usage Phone: (403) 250-3432 Fax: (403) 250-1155 www.heatlinkgroup.com...
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Warnings The zone control panel is for indoor use only and must be installed by a qualified installer/service technician. This product must be installed and operated in strict accordance with the terms set out in this manual and in accordance with the relevant requirements of the Local Authority Having Jurisdiction.
This panel does not regulate or monitor the operating safety limit temperatures of the fluid leaving the heat source. Dependant on local codes, the TMP040/TMP070 panel models may be suitable for application in either open or closed systems supplied with potable water, where the system utilizes the domestic hot water as a heat source for the hydronic system.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Panel Components WARNING!!! Consult Manual Before Use HeatLink Group Inc. WARNING!!! Consult Manual Before Use 4603E - 13th Street NE HeatLink Group Inc. AVERTISSEMENT!!! Calgary, Alberta, Canada...
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com 3-Way Thermostatic Mixing Valve (TMV) The TMV controls the temperature of the hydronic system via a self regulating thermostat. Setting the TMV To access the adjustment knob on the thermostatic mixing TMP070 valve pry the protective cap off with a fl at head screwdriver.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Mounting Wall Stud Prior to mounting the panel, ensure the wall is capable of supporting the weight of the panel. Ensure that a 120V receptacle is within reach of the 6-foot cord and plug.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Piping Hookup Primary Primary Step 1 Before making any connections, identify the Supply Return required connections to and from the panel. Adapters are ¾" M BSPP × ¾" M NPT and must use the supplied adapters and rubber washers.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Fill And Purge The following steps are recommended in order to fill the panel with water and purge entrained air once piping is completed, and before activation of the panel.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Panel Wiring Note: Terminal headers are removable to make wiring connections easier. Thermostat Wiring • 24V low voltage power may be supplied to the thermostat. Wiring of thermostat should be done by qualified electrician and should meet local codes and jurisdictions.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Panel Control Sequence When the power cord from the PLC is plugged in, and the 24Vac Plug-in Transformer is plugged in, the Green LED on the PLC will be lit indicating that the panel is powered with 110V.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Troubleshooting Problem Check / Verify Possible Cause Low Temperature Within Room Misplacement of thermostat location within Make sure thermostat is not being influenced room. by an additional heat source, such as lighting or air duct.
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com Troubleshooting (continued) Temporarily create a “permanent” heat demand: Install Jumper between W & R (closed when pump running) With jumper between W & R the pump will run.
Page 23
® Heat Link Installation, Operation, and Maintenance TMP040 / TMP070 – 3-Way Mixing Panels www.heatlink.com...