Frost Italy ULYSSE 1000-E Operation Manual

Heat recovery units

Advertisement

Quick Links

MANUALE TECNICO D'INSTALLAZIONE – Manuale d'uso
TECHNICAL INSTALLATION BOOKLET- Operation manual
RECUPERATORI DI CALORE
HEAT RECOVERY UNITS
ULYSSE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULYSSE 1000-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Frost Italy ULYSSE 1000-E

  • Page 1 MANUALE TECNICO D’INSTALLAZIONE – Manuale d’uso TECHNICAL INSTALLATION BOOKLET- Operation manual RECUPERATORI DI CALORE HEAT RECOVERY UNITS ULYSSE...
  • Page 2: Dichiarazione Di Conformita

    DICHIARAZIONE DI CONFORMITA’ CONFORMITY DECLARATION Dichiariamo, sotto la nostra esclusiva responsabilità, che la macchina in We declares that the heat recovery units it complies with Directive oggetto è conforme a: 2006/42/EC on the same applicable and relevant harmonized direttiva 2006/42/CE alla stessa applicabili e relative norme standards.
  • Page 3: General Technical Data Table

    TABELLA TECNICA DATI GENERALI GENERAL TECHNICAL DATA TABLE Modello – Model 1000-E 2000-E 3500-E Portata d’aria – Nominal air flow 1000 2000 3500 Pressione statica utile - Useful static pressure Rumorosità a 2 mt – Noise radiated to 2 meters dB(A) Ventilatore direttamente accoppiato (dati per singolo ventilatore) - Fans (data for each fan) Potenza monimale –...
  • Page 4 Where were carried out repairs or extraordinary maintenance, please rivolgersi alla FROST ITALY che provvederà a farli eseguire da personale contact FROST ITALY that will have them done by authorized personnel autorizzato o darà il consenso per poterlo far effettuare da altro or give consent to be able to be performed by other qualified personale professionalmente qualificato.
  • Page 5: Identificazione Della Macchina

    BEFORE THE WRONG WAY, OR CONTACT THE INSTALLER OR DIRECTLY ERRATO, CONTATTARE O L’INSTALLATORE O DIRETTAMENTE FROST FROST ITALY. ITALY. FROST ITALY NON SI RITERRA’ DIRETTAMENTE RESPONSABILE SE FROST ITALY NOT BE DETERMINED DIRECTLY RESPONSIBLE IF THE I COLLEGAMENTI ELETTRICI VERRANNO ESEGUITI IN MODO SCORRETTO WIRING WILL BE DONE INCORRECTLY CAUSING DAMAGE OR CAUSANDO DANNI O MALFUNZIONAMENTO DELLA MACCHINA.
  • Page 6: Collegamenti Idraulici

    COLLEGAMENTI IDRAULICI ELECTRICAL DRAWINGS Lo scarico deve essere collegato per mezzo di apposito sifone, The drain must be connected by means of a suitable siphon, ensuring accertandosi che sia libero e la gomma non abbia impedimenti ed that it is free and the rubber has not impediments and obstructions. eventuali ostruzioni.
  • Page 7 MANUTENZIONE INTERVENTI DATA CONTROLLO ANOMALIA ESITO INTERVENTO FIRMA DATE CHECK OR FAILURE RESULT ACTION SIGNATURE...
  • Page 8 The Frost Italy-UnipersonaleS.r.l. protection of their rights under the law. La Frost Italy -Unipersonale S.r.l. tutela i propri diritti a termini di legge. Frost Italy S.r.l.-UNIPERSONALE - Via Lago di Trasimeno, 46 –int.1 36015 Schio (VI) Italy - Tel.+39 0445 576772 – Fax +39 0445 576775 –...

This manual is also suitable for:

Ulysse 2000-eUlysse 3500-eUlysse 1000-7Ulysse 500-7Ulysse 1500-7Ulysse 2000-7 ... Show all

Table of Contents