Blood Glucose
Monitoring
System
A product of
w w w . p h a r m e v o . b i z
USER S MANUAL
Blood Glucose Monitoring System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM700S and is the answer not in the manual?

Questions and answers

Munawar
July 21, 2025

My GM 700s is directly giving ful display data all like reading digit, memory ,date time ,blue tooth, just after inserting battery even I did not press any button. Kindly guide

User image 687df16763b05

Summary of Contents for Evocheck GM700S

  • Page 1 四色印刷 GM700S Blood Glucose Monitoring System A product of A product of w w w . p h a r m e v o . b i z USER S MANUAL w w w . p h a r m e v o . b i z E-mail: evocheck@pharmevo.biz...
  • Page 3 GM700S . This manual Blood Glucose Monitoring System GM700S is a personal blood glucose monitoring provides all the information you need to operate this product for accurate test results. Please read system to be used for self-testing only. It is not recommended for multiple users.
  • Page 4 An Er4 reading will be displayed if the sample size is too small. In this case, repeat the test with a System GM700S is intended for in vitro diagnostic use only. The test results using new test strip.
  • Page 5: Table Of Contents

    Table of Contents Table of Contents About the Blood Glucose Monitoring System GM700S Quality Control About Quality Control Testing......................Blood Glucose Monitoring System GM700S ............... Performing a Quality Control Test......................Blood Glucose Meter GM700S .................. Understanding Control Test Results....................Blood Glucose Test Strip GS700 .................
  • Page 6 Blood Glucose Test Strip GS700 Package Insert * Control Solution GC700 Insert * Blood Glucose Meter GM700S ( with 1 CR2032 battery installed ) Blood Glucose Test strips GS700 ( 10/25 pcs )* Control Solution GC700 *(Normal Level is provided in your starter kit) Lancing Device *...
  • Page 7: The

    Blood Glucose Meter GM700S Blood Glucose Meter GM700S Test Strip Port GM700S Display Window Main Button ( Meter Battery Battery Cover Left Button ( Right Button ( 2D barcode with serial number...
  • Page 8 Blood Glucose Meter GM700S Blood Glucose Meter GM700S Indicates a test result stored in memory Indicates when to apply the blood sample Indicates a test result not included into the Appears after you insert test strip into meter average results of the meter...
  • Page 9: The

    (< 90% relative humidity). Do not expose to direct sunlight or heat. Insert strip with indication symbol This window is yellow - If the Blood Glucose Meter GM700S and Test Strips are exposed to a up and toward meter. before applying blood temperature outrange environment, please wait 30 minutes before testing.
  • Page 10: Meter Activation And Battery Change

    1,000 tests under normal use. Press the main button or insert a strip to activate your meter. 1. Turn the GM700S Blood 2. Install the battery. Be sure 3. Slide the battery cover back Glucose Meter over.
  • Page 11: Setting Up Your Meter - Setting The Date, Time And Volume

    Month Setting will appear. then follow the battery installation steps to replace battery. The Blood Glucose Meter GM700S will perform a self-test. Press the main button to exit the self-test and enter the Setting Mode. 2. With Battery Inserted 2.
  • Page 12 Setting will appear. - If you do not change any settings during Meter Set-up for over 2 minutes, the Blood Glucose Meter GM700S will leave setting mode and power off automatically. - Your Meter default unit is set as "mg/dL".
  • Page 13: Turning On/Off The Meter

    Turning On / Off the Meter Handling the Blood Glucose Test Strip GS700 1. How to turn on the Blood Glucose Meter GM700S How to handle the ood Glucose Test Strip GS700 Press the Main button or Insert a test strip.
  • Page 14: Getting Ready For Testing

    Before performing a blood glucose test, prepare the items below : 1. Hold the Blood Glucose Test Strip GS700 as shown. GM700S GM700S Blood Glucose Meter GM700S Blood Glucose Test Strips GS700 (Please check the expiration date on the test strip 2.
  • Page 15: Performing A Blood Glucose Test

    Close the vial cap immediately. 10. Insert the strip into the test strip port of the 4. Twist off and set aside the protective cover of the Blood Glucose Meter GM700S with the view window disposable lancet. facing up.
  • Page 16 Performing a Blood Glucose Test Performing a Blood Glucose Test 12. A blood drop icon will appear on the display window 16. Pull off the depth adjustable cap. Without touching the and will be accompanied by a beep (if volume is turned used disposable lancet, insert the lancet tip into the on).
  • Page 17: Setting Markers

    Before meal: You execute this blood glucose test before a meal. - The Blood Glucose Monitoring System GM700S and Lancing device After meal: You execute this blood glucose test after a meal.
  • Page 18: View Window Appearance

    - Apply the blood sample only on the sample port of the test strip. - Please don't drip or inject the blood sample directly by syringe to the sample GM700S entry of test strip. Doing this might contaminate the meter or cause damages...
  • Page 19: Understanding Test Results And Messages

    Blood Glucose screen. Please repeat your test with by a new test strip. Monitoring System GM700S in the Control Solution Mode. If the test result is within the Control If you still get a “ ” result, contact your healthcare professional.
  • Page 20 When should a Quality Control Test Be Performed ? CAUTION - To ensure that your Blood Glucose Meter GM700S Blood Glucose Test - Each time you open a new bottle of control solution, write the expiration date on the label. Strip GS700 are working properly.
  • Page 21 " appear, do not touch the control solution to the sample port on the Solution GC700. strip. The Blood Glucose Meter GM700S is performing an internal check. 5. Shake the bottle of Control Solution GC700 well before Touching the control solution to the sample port before prompted will result in an error opening the cap.
  • Page 22: Understanding Control Test Results

    " appears next to the data, the test was performed using the Monitoring System GM700S may not be working properly. Repeat the Quality Control Test. If your Control Solution GC700. The control solution test result will not be used when...
  • Page 23 Recalling Average Test Results Recalling Average Test Results Blood Glucose Meter GM700S provides several average test results. View the 1-day, 5. Quick Searching: 7-days, 14-days, 30-days, 60-days and 90-days average test results for better blood glucose To view test results in sequential order automatically, enter the Memory Mode. Press the Right or monitoring.
  • Page 24: Error Messages And Troubleshooting

    Clean the outside of the meter with a damp cloth and mild soap/detergent. Do not get the test strip port wet. If the Blood Glucose Meter GM700S and Test Strips are exposed to a temperature outrange environment, please wait 30 minutes before testing. Cleaning Test Strip Port If your test strip port is stained with blood, control solution or any liquid, please use a dry tissue or alcohol swab to clean it immediately.
  • Page 25 Blood Glucose Test If the Blood Glucose Meter GM700S will not turn on, please follow the steps below: Strip GS700. 1. Open the battery cover and remove the battery. 2. Wait for 5 minutes and reinsert the battery as described as instructed on page 16 (Meter Sampling Error Activation and Changing the Battery).
  • Page 26 Error Messages and Troubleshooting Limitations Blood Glucose Monitoring System GM700S is not intended for serum or plasma testing. CAUTION - Inaccurate test results may be obtained at altitudes greater than 10,000 feet (3,048 meters) above A blood sample should ONLY be applied to the test strip after the test strip has been sea level.
  • Page 27 Specification Specification 20 ~ 70 % when blood glucose ≤ 200 mg/dL (11.1 mmol/L), Measurement Technology Hematocrit Dehydrogenase Electrochemical Sensor 20 ~ 60 % when blood glucose > 200 mg/dL (11.1 mmol/L) Sample Capillary, Venous, Arterial and Neonatal whole blood One CR2032 Battery (3 Voltage) Power Supply Minimum Sample Volume...
  • Page 28: Customer Service

    For single use only Recyclable Package Different models have different specifications. This warranty applies only to the Blood Glucose Monitoring System GM700S; other models are not covered with this warranty card. Consult the instruction for use Biological risks Temperature limitation...
  • Page 29 Disposable Sterile Lancets Manufacturer: SteriLance Medical (SuZhou) Inc. No.68 LiTangHe RD, XiangCheng, SuZhou, JiangSu 215133, P .R. China Product complies with Medical Device Directive 93/42/EEC (CE 0197). EC- Rep: EMERGO EUROPE, Molenstraat 15, 2513 BH The Hague, The Netherlands E-mail: evocheck@pharmevo.biz...