9-1-2. Optional Installation Parts
Part
Parts name
code
Refrigerant piping
A
Liquid side
: Ø6,35
Gas side
: Ø9,52
Pipe insulating material
B
(Polyethylene foam, 6mm thick)
C
Putty, PVC tapes
9-1-3. Accessory and Installation Parts
Part
Part name (Q'ty)
No.
1
Installation plate x 1
2
Wireless remote controller x 1
3
Battery x 2
4
Remote controller holder x 1
9-1-4. Installation/Servicing Tools
In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged
accidentally, to service port diameter of the outdoor unit control valve (3 way valve) has been changed.
(1/2 UNF 20 threads per inch)
• In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and
size of opposite side of flare nuts has been changed.
(for copper pipes with nominal dimensions 1/2 and 5/8)
New tools for R410A
New tools for R410A
Applicable to R22 model
× × × × ×
Gauge manifold
× × × × ×
Charge hose
¡
Electronic balance
for refrigerant charging
× × × × ×
Torque wrench
(nominal diam. 1/2, 5/8)
¡
Flare tool (clutch type)
——
Gauge for projection adjustment
¡
Vacuum pump adapter
× × × × ×
Gas leakage detector
• Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating
in the U. S's ARI specified rose color (ARI color code: PMS 507).
• Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch correspond-
ing to the charge hose's port size.
More user manuals on
ManualsBase.com
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with the fixing bolts and nuts if the
Q'ty
unit is likely to be exposed
to a strong wind.
Each
• Use ø8 mm or ø10 mm
one
anchor bolts and nuts.
• If it is necessary to drain
the defrost water attach
1
drain nipple to the bottom
plate of the outdoor unit
Each
before installing it.
one
Part
Part name (Q'ty)
No.
5
Mounting screw Ø4 x 25 x 6
6
Purifying filter x 1
7
Deodorizing filter x 1
8
Pan head wood screw Ø3,1x 16 x 2
Changes in the product and components
Changes
As pressure is high, it is impossible to measure by means of
conventional gauge. In order to prevent any other refrigerant from
being charged, each port diameter has been changed.
In order to increase pressure resisting strength, hose materials and
port size have been changed (to 1/2 UNF 20 threads per inch).
When purchasing a charge hose, be sure to confirm the port size.
As pressure is high and gasification speed is fast, it is difficult to read
the indicated value by means of charging cylinder, as air bubbles
occur.
The size of opposite sides of flare nuts have been increased. Incidentally,
a common wrench is used for nominal diameters 1/4 and 3/8.
By increasing the clamp bar's receiving hole, strength of spring in the
tool has been improved.
Used when flare is made by using conventional flare tool.
Connected to conventional vacuum pump. It is necessary to use an
adapter to prevent vacuum pump oil from flowing back to the charge
hose. The charge hose connecting part has two ports-one for
conventional refrigerant (7/16 UNF 20 threads per inch) and one for
R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge
may occur and damage the equipment.
Exclusive for HFC refrigerant.
Exclusive for HFC refrigerant.
9-2. Indoor Unit
9-2-1. Installation Place
• A place which provides the spaces around the
600
indoor unit as shown in the above diagram.
Suction side
• A place where there is no obstacle near the air
115
inlet and outlet.
• A place which allows an easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
Drain hole
Diffuser
opened.
Fig. 9-1-2
CAUTION
• Direct sunlight to the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should not
Name
be too close to r-f noise sources.
(For details, see the owner's manual.)
Owner's manual
Others
Remote controller
• A place where there are no obstacles such as a
Installation manual
curtain that may block the signal from the indoor
unit.
This model is not equipped with
an extention drain hose.
• Do not install the remote controller in a place
Option :
exposed to direct sunlight or close to a heating
For the extention drain hose, use
source, such as a stove.
an optionally available RB-821SW
• Keep the remote controller at least 1 m apart from
or commercially available one.
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
Reception
range
9-2-2. Cutting a Hole and Mounting
Installation Plate
Cutting a Hole
When install the
refrigerant pipes
from the rear.
1. After determining the pipe hole position on the
mounting plate (80 mm
(ø65 mm) at a slight downward slant to the
outdoor side.
NOTE
• When drilling the wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe
hole brim ring sold separately.
Mounting the Installation Plate
For installation of the indoor unit, use the
paper pattern on the back.
120mm
65,5mm
Pipe
hole
Indoor unit
When the installation plate is directly
mounted on the wall
1. Securely fit the installation plate onto the
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2. To mount the installation plate on a
concrete wall with anchor bolts, utilize the
anchor bolt holes as illustrated in the
above figure.
3. Install the installation plate horizontally in
the wall.
CAUTION
When installing the installation plate with
mounting screw, do not use the anchor
bolt hole. Otherwise the unit may fall down
and result in personal injury and property
damage.
(Top view)
Indoor unit
Reception
Remote
Remote
range
controller
controller
*
: Axial distance
Fig. 9-2-1
5 mm dia. hole
The center of the piping slot
is above the arrow.
CAUTION
The center of the pipe
hole is above the arrow.
Pipe hole
Failure to firmly install the unit may result
80mm
in personal injury and property damage if
the unit falls.
Fig. 9-2-2
• In case of block, brick, concrete or similar
type walls, make 5 mm dia. holes in the
wall.
), drill the pipe hole
• Insert clip anchors for appropriate
mounting screws.
NOTE
• Install the installation plate using 4 to 6
pieces of mounting screw securing four
corners with screws.
Anchor bolt hole
40mm
66mm
65,5mm
Pipe hole
1
Installation
Thread
5 Mounting
plate
screw
Weight
Fig. 9-2-3
Anchor bolt
Projection
15mm or less
Fig. 9-2-4
5 Mounting screw
Ø4 x 25
Clip anchor
Fig. 9-2-5
(local parts)