W&T Electronics 58210 Manual

Lan-modem

Advertisement

Quick Links

Manual
LAN-Modem
W&T
Release 1.2, March 2002
Model
58210, 58220
58610, 58620

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 58210 and is the answer not in the manual?

Questions and answers

Summary of Contents for W&T Electronics 58210

  • Page 1 Manual LAN-Modem Release 1.2, March 2002 W&T Model 58210, 58220 58610, 58620...
  • Page 2 W&T © 03/2002 by Wiesemann und Theis GmbH Subject to error and alteration: Since it is posssible that we make mistakes, you mustn’t use any of our statements without verification. Please, inform us of any error or misunderstanding you come about, so we can identify and eliminate it as soon as possible.
  • Page 3 W&T Introduction The LAN-Modem permits devices that require dial-up m o d e m s f o r c o m m u n i c a t i n g t o u s e t h e I n t r a n e t o r Internet instead of the telephone system.
  • Page 4: Table Of Contents

    Installation in flow chart form 2 Connections and Displays Ethernet connection 2.2 The RS232 connection 2.3 Supply voltage 2.3.1 5V supply voltage (58210, 58220) 2.3.2 12–24V supply voltage (58611, 58620) 2.4 LED displays 3 TCP/IP Configuration 3.1 Assigning the IP using the „ARP“ command 3.2 Assigning the IP through the serial port...
  • Page 5 W&T 4.4.14 &Fn (AT&F[0|1]) 4.4.15 &K (AT&K[0|3|4|5|6]) 4.4.16 &Sn (AT&S[0|1]) 4.4.17 &Vn (AT&V[0|1|2]) 4.4.18 &Wn(AT&W[0|1]) 4.4.19 &Yn (AT&Y[0|1]) 4.4.20 &Zn=x (AT&Z[0|1|2|3]=[IP address]) 4.4.21 %Bn (AT%B[2-8]) 4.4.22 %Dn (AT%D[7|8]) 4.4.23 %Pn (AT%P[0|1|2]) 4.4.24 %Sn (AT%S[1|2]) 4.4.25 %Nn (AT%N[0|1]) 4.4.26 ** (AT**) 5 Firmware-Update 5.1 Where do I get the latest firmware? 5.2 Serial update of the AT command interpreter...
  • Page 6 W&T...
  • Page 7: Quick Installation

    W&T Quick Installation LAN-Modem installation in flow chart form Subject to error and alteration...
  • Page 8: Installation In Flow Chart Form

    W&T Schnellinstallation Installation in flow chart form The following diagram shows the essential installation steps for any LAN-Modem installation. Intranet / Internet LAN-Modem LAN-Modem (x) Standortwahl - Anschluß der Spannungsversorgung Anschluß der - Netzwerk-Anschluß über Patchkabel Hardware - Verbindung der seriellen Schnittstellen 1.) Statischer Eintrag in ARP-Cache eines Rechners im selben Subnet: Einstellung der...
  • Page 9: Connections And Displays

    W&T Connections and Displays Pin Assignments Supply Voltage LED displays Subject to error and alteration...
  • Page 10: Ethernet Connection

    10BaseT (Typ 58210, 58610) T h e s e d e v i c e s o p e r a t e c o n f o r m a l w i t h t h e 1 0 B a s e T standard at 10MBit/s.
  • Page 11 W&T Connections and Displays 100MBit/s is appropriate cabling (Cat 5/ISO Class D or better). The current link status is indicated by the Error LED on the front panel: If it blinks at 1-2 second intervals, there is no connection to the hub, or the connection is faulty. Subject to error and alteration...
  • Page 12: The Rs232 Connection

    W&T Connections and Displays 2.2 The RS232 connection The pin assignments for the RS232 port are identical with that of a dialup modem, which means that standard cable can be used. Make sure that the prots for the LAN-Modem and the serial terminal device are configured for identical transmission parameters and handshake procedures.
  • Page 13: Supply Voltage

    12V and 24V. 2.3.1 5V supply voltage (58210, 58220) The supply voltage for models 58210 and 58220 is brought in through the power terminal located on the underside of the housing. The supply voltage is 5V +/- 5%.
  • Page 14: Led Displays

    W&T Connections and Displays 2.4 LED displays Status and error information is indicated by the LAN-Modem using three LEDs having various blink codes. • Power-LED Indicates the presence of supply voltage. If the LED is For additional n o t f u l l o n , p l e a s e c h e c k y o u r p o w e r s u p p l y informatio on the settings, please refer connections.
  • Page 15: Tcp/Ip Configuration

    W&T TCP/IP Configuration Following the hardware installation, this section describes the logical integration of the LAN-Modem into the TCP/IP network. Assigning the IP address Setting the Subnet-Mask and Gateway You can obtain all the parameters from the system administrator of your network.
  • Page 16: Assigning The Ip Using The „Arp" Command

    W&T TCP/IP Configuration 3.1 Assigning the IP using the „ARP“ command This method can only be used if the LAN-Modem does not yet have an IP address, i.e. the current entry is 0.0.0.0. To change an IP address, use one of the other methods described in this section or use the configuration menu via TELNET.
  • Page 17 W&T TCP/IP Configuration The LAN-Modem accepts the IP address of the first network packet sent to it as its own and saves it in non-volatile RAM. Every IP address must Only now is the Telnet connection established and the be used only once in the network.
  • Page 18: Assigning The Ip Through The Serial Port

    W&T TCP/IP Configuration 3.2 Assigning the IP through the serial port After the LAN-Modem has been reset, a time window of approx. 1-2 seconds is provided during which you can assign a new IP address by entering at least three „x“. In contrast to the previously described using ARP, this serial path works regardless of whether the L A N - M o d e m a l r e a d y h a s a n I P a d d r e s s o r n o t .
  • Page 19: Serially Deactivating The Dhcp-/Bootp-Client

    W&T TCP/IP Configuration 3.2.1 Serially deactivating the DHCP-/BOOTP-Client The DHCP-/BOOTP function of the LAN-Modem can be turned off when serially assigning the IP address. We recommend doing this in all cases where it is not absolutely necessary to use DHCP/BOOTP to assign the IP. To deactivate the DHCP-/BOOTP client, attach the option „-0“...
  • Page 20: Assigning The Ip Using An Rarp Server

    W&T TCP/IP Configuration 3.3 Assigning the IP using an RARP server UNIX environments in particular often use the RARP protocol for centralized assignment of IP addresses. This means that TCP/IP devices that want to obtain an IP address send RARP requests with their Ethernet address as a broadcast over the network.
  • Page 21: Assigning The Ip Using Dhcp-/Bootp Protocol

    W&T TCP/IP Configuration 3.4 Assigning the IP using DHCP-/BOOTP protocol Many network use DHCP (Dynamic Host Configuration P r o t o c o l ) o r B O O T P f o r c e n t r a l i z e d a n d d y n a m i c assignment of IP addresses.
  • Page 22: Deactivating The Dhcp-/Bootp Protocol

    W&T TCP/IP Configuration After the administrator has made the necessary entries, the LAN-Modem will automatically obtain the desired IP address after each reset. To ensure the availability of the LAN-Mo- dem even should the DHCP/BOOTP server fail, the previous IP address is kept if no reply comes. In DHCP environments the IP address to be assigned must be reserved by means of a fixed link to the Ethernet address of the LAN-Modem.
  • Page 23 W&T TCP/IP Configuration • The serial port is used to assign the IP address for the LAN-Modem. By sending „xxx“ to the LAN-Modem during a restart, you arrive at the input mode for a new IP address. If you enter this followed by the string „-0“, the BOOTP client of the LAN-Modem will be deactivated (see Older Windows systems will only...
  • Page 24: Configuring The Subnet Mask And Gateway

    W&T TCP/IP Configuration 3.5 Configuring the subnet mask and gateway When working in routed environments, the LAN-Modem must be told the responsible router in addition to the subnet mask which is valid for the respective network segment. Valid values for both parameters can be obtained from your systems administrator.
  • Page 25 W&T TCP/IP Configuration The entry fields for the subnet mask and the gateway address are reached through the following menu path: 1. INFO Com Server 2. SETUP System 1. Setup TCP/IP 1. IP-Address 2. Set Password 2. Subnet Mask 3. SETUP Port 0 3.
  • Page 26 W&T...
  • Page 27: Modem Operation

    W&T Modem Operation After the netework configuration is complete, the LAN-Modem behaves on the serial side just like a dial-up modem with an AT command set, except that the TCP/IP LAN takes the place of the telephone line. As far as the controlling application or controlling device is concerned, all that needs to happen is that the previously used telephone number is replaced by the IP address of the distant terminal.
  • Page 28: Serial Transmission Parameters

    W&T Modem Operation 4.1 Serial transmission parameters Unlike modems for the telephone network, the LAN-Mo- dem is not able to automatically detect the baud rate of t h e t e r m i n a l . T h e f o l l o w i n g t r a n s m i s s i o n f o r m a t i s factory set: Baud: 9600...
  • Page 29: Command Syntax

    W&T Modem Operation 4.2 Command syntax The LAN-Modem accepts all the AT described in the following sections as long as they corresponding to one of the following patterns and are finished with a CR: letter [number] & letter [number] letter [number] letter [number]...
  • Page 30: Command And Data Mode

    W&T Modem Operation 4.3 Command and data mode The LAN-Modem distinguishes on the serial side between two mode states: command and data mode. • Command mode In this mode, which is activated after power-on, the A T c o m m a n d i n t e r p r e t e r o p e r a t e s o n t h e s e r i a l interface.
  • Page 31: All At Commands

    W&T Modem Operation 4.4 All AT commands The LAN-Modem accepts all the commands in the table whose processing is done according to the following rules: Befehl Beschreibung Parameter IP-Adresse anwählen und online gehen IP-Adresse Ankommenden Ruf annehmen Zu einer bestehenden Verbindung zurückkehren Verbindung beenden Verbindung beenden und Modem zurücksetzen n=0, 1...
  • Page 32: A (Ata)

    W&T Modem Operation • No other command may follow A, D, O, Z and &Z in the same command line. In the case of A, O and Z they are ignored, and in the case of D and &Z they are considered as part of the dialed number.
  • Page 33: D (Atd[Ip Address])

    W&T Modem Operation 4.4.2 D (ATD[IP address]) = Dial command T h e d i a l c o m m a n d i s r e q u i r e d f o r e s t a b l i s h i n g a connection with another LAN-Modem.
  • Page 34 W&T Modem Operation • S=0|1|2|3 The LAN-Modem has a non-volatile memory for up to four destination IP addresses. By specifying a value between 0 and 3, the IP addresses stored here is used for the call set-up. If only „S“ is entered without a numerical value, the addresses stored in position 0 is used.
  • Page 35 W&T Modem Operation Replies for the dial-up command • CONNECT The network connection with the desired destination s y s t e m w a s s u c c e s s f u l l y m a d e , a n d t h e s e r i a l application connected therre accepted the call.
  • Page 36: E (Ate[0|1])

    LAN-Modem. Of a possible 0-8, only parameters 0 and 3 are presently used. The remaining even options are reserved for later enhancements. • ATI0 Returns product code „58210" from the LAN-Modem • ATI8 Returns the firmware version of the AT command interpreter...
  • Page 37: O (Ato)

    W&T Modem Operation 4.4.6 O (ATO) = Switch to data mode T h i s c o m m a n d s w i t c h e s ( w h e n t h e r e i s a n e x i s t i n g connection) from command to data mode.
  • Page 38: Sn=X (At[0-40]=[0-255])

    W&T Modem Operation 4.4.9 Sn=x (AT[0–40]=[0–255]) = Set S register The LAN-Modem has 41 S registers (S0 to S40) which determine its operating behavior. The command Sn=x is used to overwrite the current contents, whereby „n“ specifies the desired register and „x“ the value to write in decimal format.
  • Page 39: Vn (Atv[0|1])

    W&T Modem Operation • The value of register S9 is adjusted to the value of S10 each time a connection is set up. 4.4.10 Vn (ATV[0|1]) = Result codes in plain text Default setting: 1 = ON This command specifies whether result returns from the LAN-Modem are to be numerical or in plain text.
  • Page 40: Zn (Atz[0|1])

    W&T Modem Operation 4.4.11 Zn (ATZ[0|1]) = Reset the LAN-Modem The Zn command quits any active connection and resets the firmware of the LAN-Modem to the parameters stored in the non-volatile memory. By specifying „0“ or „1“ you can select one of the two available reset profiles (see also &Wn command).
  • Page 41: D (At&C[0|1|2|3])

    W&T Modem Operation 4.4.13 &D (AT&C[0|1|2|3]) = Modem response to DTR option Default setting: 2 Defines the effect of a level change on the DTR input on the LAN-Modem. One of four functions may be selected: • &D0 The LAN-Modem ignores the signal. •...
  • Page 42: K (At&K[0|3|4|5|6])

    W&T Modem Operation 4.4.15 &K (AT&K[0|3|4|5|6]) = Flow control Default setting: 3 = RTS/CTS This command determines the flow control between the LAN- Modem and the connected serial device: • &K0 (no handshake) Flow control is turned off. The LAN-Modem sends all data to the serial device regardless of the status of the handshake input RTS.
  • Page 43: Sn (At&S[0|1])

    W&T Modem Operation • &K6 (RTS/CTS + Xon/Xoff) Flow control is handled by RTS/CTS and Xon/Xoff. The m o d e m g e n e r a t e s s i g n a l s f o r b o t h h a n d s h a k e procedures and allows itself to be prevented from continuing to send by means of Xoff or a returned RTS.
  • Page 44: Wn(At&W[0|1])

    W&T Modem Operation • &V1 The LAN-Modem returns statistics for the last TCP/IP connection. • &V2 T h e L A N - M o d e m s e n d s a s a r e p l y i t s c o m p l e t e configuration coded in S record format.
  • Page 45: Zn=X (At&Z[0|1|2|3]=[Ip Address])

    W&T Modem Operation 4.4.20 &Zn=x (AT&Z[0|1|2|3]=[IP address]) = Save destination IP address The LAN-Modem can save up to 4 destination IP addresses in its non-volatile memory, which can later be recalled using the fast dial function (Sn=x) of the dial command. Example: AT&Z1=172.16.2.2 IP address 172.16.2.2 is stored in memory location 1.
  • Page 46: Dn (At%D[7|8])

    W&T Modem Operation 4.4.22 %Dn (AT%D[7|8]) = Number of data bits per character Default setting: 8 This command determines whether the serial character format works with 7 or 8 data bits. The %D command has a delayed effect. The first OK reply is still with the old data format.
  • Page 47: Sn (At%S[1|2])

    W&T Modem Operation 4.4.24 %Sn (AT%S[1|2]) = Minimum number of stop bits between 2 characters Default setting: 1= 1 stop bit This command determines how many stop bits (minimum) appear between 2 serial characters. The %S command has a delayed effect. The first OK reply is still with the old data format.
  • Page 48: At**)

    W&T Modem Operation 4.4.26 ** (AT**) = Start flash update Updating the firmware or sending a configuration file must be introduced with the ** command. The LAN-Modem generates the following message and then expects the update data in Motorola S Record format. If no data are sent within 30s, the mode is automatically quit.
  • Page 49: Firmware-Update

    W&T Firmware-Update The firmware for the LAN-Modem is divided into two function modules whoses update methods differ. Update the AT command interpreter serially or over the network Update the TCP/IP-Stack over the network Subject to error and alteration...
  • Page 50: Where Do I Get The Latest Firmware

    W&T Firmware-Update 5.1 Where do I get the latest firmware? The current firmware including the update tool and a revision list is published on our Web site at the following address: http://www.wut.de. Before proceeding with the update, please write down the 5-digit model number located on the LAN-Modem.
  • Page 51: Serial Update Of The At Command Interpreter

    W&T Firmware-Update 5.2 Serial update of the AT command interpreter For this the LAN-Modem must have a serial connection to a terminal program whose transmission parameters are configured as follows: Baud rate: same as the LAN-Modem Data format: 8 data bits, no parity, 1 stop bit Handshake: RTS/CTS (required) The command AT** is used to place the LAN-Modem in...
  • Page 52: Network Update Of The At Command Interpreter

    W&T Firmware-Update 5.3 Network update of the AT command interpreter Updating the firmware over the network offers the advantage of a higher speed compared with the serial method. The p r e r e q u i s i t e h o w e v e r i s t h a t n e t w o r k - s i d e r e m o t e maintenance be enabled by the command %N1.
  • Page 53 W&T Firmware-Update When starting update mode over the network, the serially connected device is informed of the access with a short message. The update mode is protected with a timeout of 30s. If no data are transmitted within this time, the LAN-Modem automatically resumes normal operating mode.
  • Page 54: Updating The Tcp/Ip-Stack

    W&T Firmware-Update 5.4 Updating the TCP/IP-Stack Prerequisite is a PC running under Windows 9x/NT/2000 with a network connection and an installed TCP/IP stack. You need two files for the update process: 1. The Update-Tool (32-bit application for Windows9x/ NT/2000), used to perform the update, and 2.
  • Page 55 W&T Firmware-Update IN the option field „Output“ please select only the item „Firmware“. 5. Click on the Start button. The update will take several secnds. It is only finished when a message window reports the end of the update process. 6.
  • Page 56 W&T...
  • Page 57: Appendix

    W&T Appendix Reading and sending complete configuration profiles The modem protocol on the TCP level Using with W&T COM Port Redirector and virtual modem ports Technical Data Subject to error and alteration...
  • Page 58: Reading/Sending Configuration Profiles

    W&T Appendix Reading/Sending Configuration Profiles To simplify the configuration of the LAN-Modem when using a greater number of devices, it is possible to copy t h e c o n f i g u r a t i o n d a t a . T o d o t h i s , y o u m u s t f i r s t configure a LAN-Modem for the desired operating mode using the AT commands.
  • Page 59: The Modem Protocol On The Tcp Level

    W&T Appendix The Modem Protocol on the TCP Level Normally LAN-Modems will be used only to connect to each other. It is however conceivable that an application program uses TCP/IP programming to direct dial an individual LAN-Modem or to be called by the LAN-Modem. The information required for doing this can be obtained on request.
  • Page 60: Virtual Modem Ports Under Windows Nt/2000/Xp

    W&T Appendix Virtual Modem Ports under Windows NT/2000/XP As is the case with standard dial-up modems, the LAN- Modems are generally used in pairs, with one LAN-Mo- dem used to dial-up another. If in a serial application this involves an application running under Windows NTW, 2000 or XP, a LAN-Modem is not required on this side.
  • Page 61: Technical Data

    80mA max. 110mA Typ 58620@24V/DC: typ. 175mA max. 225mA zulässige Umgebungstemperatur bei freier Luftzirkulation, nicht angereiht: Typ 58210, 58220, 58610, 58620: 0 - 60°C zulässige Umgebungstemperatur bei angereihter Montage auf Hutschiene: Typ 58210, 58610: 0 - 60°C Typ 58220, 58620: 0 - 60°C...
  • Page 62: Declaration Of Conformity

    W&T Appendix Declaration of conformity...
  • Page 63 W&T...

This manual is also suitable for:

582205861058620

Table of Contents