Download Print this page

Viking DLE-300 Product Manual page 5

Advanced line simulator
Hide thumbs Also See for DLE-300:

Advertisement

B. Internal DIP Switch Programming
Switch
1
1
2
2
3
3
4
4
Switch 5
OFF
ON
Switch
7
7
Position
Description
OFF
Disables CPC signal
ON
* Enables CPC signal
OFF
Disables "Caller ID" data
ON
* Enables "Caller ID" data
OFF
Disables maximum ring count
ON
* Enables maximum ring count
OFF
10 seconds of dialtone when other phone hangs up
ON
* 10 seconds of fast busy tone when other phone hangs up
Switch 6
Description
ON
Audio volume between ports is attenuated by 9dB
OFF
* Device ports are connected with no attenuation
Position
Description
OFF
* Two-way ringdown
ON
One-way ringdown: device 1 to device 2 only
on
1 2 3 4 5 6 7
on
on
1
2
3
4
5
6
7
5

Advertisement

loading