PIP On/Off control
•
Function
The PIP mode of a product can be turned on or off using a PC.
― Only available on models that have the PIP function.
― The mode cannot be controlled if
― This function is not available in MagicInfo.
•
Viewing PIP on/off state (Get the PIP ON / OFF Status)
Header
Command
ID
0xAA
0x3C
•
Setting PIP on/off (Set the PIP ON / OFF)
Header
Command
ID
0xAA
0x3C
"PIP": A code used to turn the PIP mode of a product on or off
1: PIP ON
0: PIP OFF
•
Ack
Header
Command
ID
Data
length
0xAA
0xFF
3
"PIP": A code used to turn the PIP mode of a product on or off
•
Nak
Header
Command
ID
Data
length
0xAA
0xFF
3
"ERR": A code showing what error has occurred
Video Wall
is set to On.
Data length
Checksum
0
Data length
Data
Checksum
1
"PIP"
Ack/Nak
r-CMD
Val1
'A'
0x3C
"PIP"
Ack/Nak
r-CMD
Val1
'A'
0x3C
"PIP"
Safety Lock
•
Function
PC can be used to turn the
This control is available regardless of whether or not the power is turned on.
•
Viewing the safety lock state (Get Safety Lock Status)
Header
Command
0xAA
0x5D
•
Enabling or disabling safety lock (Set Safety Lock Enable / Disable)
Header
Command
0xAA
0x5D
"Safety Lock": Safety lock code to be set on a product
1: ON
0: OFF
•
Ack
Header
Command
Checksum
0xAA
0xFF
"Safety Lock": Safety lock code to be set on a product
•
Nak
Header
Command
Checksum
0xAA
0xFF
"ERR": A code showing what error has occurred
Safety Lock
function on or off on a product.
ID
Data length
Checksum
0
ID
Data length
Data
1
"Safety
Lock"
ID
Data
Ack/Nak
r-CMD
length
3
'A'
0x5D
ID
Data
Ack/Nak
r-CMD
length
3
'N'
0x5D
Checksum
Val1
Checksum
"Safety Lock"
Val1
Checksum
"ERR"
20