Page 2
CE marking should it be required. In this case, this user manual does not apply, and reference should be made to Antares (Europe) Limited for any information required for compliance with the legislation.
Page 3
The best performance will be achieved with the line charger located as close as possible to the batteries to be charged, and connected with cables giving minimal voltage drop. If this cannot be achieved, then the remote battery voltage & temperature sensor should be used. Further guidance is given at the end of this manual.
Page 4
The first connection to be made is the battery negative connection; one of the black wires (either will do) emerging from the DC charger should be connected directly to the negative terminal of the battery to be charged. The second connection is the other black wire; which should be connected to the input supply negative.
Page 5
When a charging source is not present, it switches to a low power sleep mode. SPECIFICATIONS Model range: Input voltage Input current Output voltage Model number, Model number, with remote sense no remote sense 91136 91126 91141 91131 91135 91125 91140 91130 91138 91128...
Page 6
INSTALLATION CABLE SIZING Cables & any connectors should be selected to carry the following maximum current: Model Input current (maximum) Output current (maximum) All models 15 amps 33 amps 12 amps 30 amps Input cables The line charger will operate successfully with the input voltage as low as 12 volts, however, this will reduce the output power available for battery charging.
Need help?
Do you have a question about the 91136 and is the answer not in the manual?
Questions and answers