Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk The Help Centre section of this website also features a wide range of information which may be of use to you and is available 24 hours a day. It includes: • Manuals and guides downloads • Servicing • Where to buy our products • Literature downloads www.robinsonwilley.co.uk/help A division of GDC Group Ltd Registered No: 1313016 England VAT GB 287 1315 50004 Millbrook House Grange Drive Hedge End Southampton SO30 2DF EEE Producer Registration Number –...
Page 2
988939 Issue 8 Bantam Ecotherm Instructions for Installation and Servicing This is a Cat I appliance - for use on G20 @ 20mbar in GB & IE Please leave these instructions with the User...
DESCRIPTION The Bantam Ecotherm is a room sealed gas wall heater which circulates warm air by convection. It is manually ignited by a combined piezo igniter and gas tap which has OFF, PILOT and ON positions. The setting of the thermostat and the room temperature determine if the main burner lights when the gas tap is turned to ON, after lighting the pilot.
Page 4
PART 1. INSTALLATION 1. CONDITIONS OF INSTALLATION This appliance is for use on natural gas only. It is the law that all gas appliances are installed by a competent person ( a Gas Safe registered Engineer ) in accordance with the Gas Safety (Installation and Use) Regulations. Failure to install appliances correctly could lead to prosecution.
2m from the level of any ground, balcony, flat roof or place to which any person has access and which adjoins the wall in which the outlet is situated. A suitable guard is available from Robinson Willey Ltd. The Part No. of the guard is 994371.
Page 6
4. PREPARATION OF WALL 4.1 INSTALLATION ON NORMAL BRICK WALL 1 . Open the carton and remove the contents, putting them to one side to avoid damage. The heater should be placed carefully on the floor, avoid damaging the thermostat phial. Using the template supplied place it against the wall.
Page 7
4.2 INSTALLATION OF HEATER ON COMBUSTIBLE WALLS Note: The combustible wall kit (Part No. 994530) is required. It is only suitable for walls on which the combustible part is not more than 207mm (8in) thick, measured from the inside face of the wall. Reference should be made to BS 5871, the Building Regulations and, for walls of timber framed/brick construction, The Institute of Gas Engineers Utilization Procedure IGE/UP/7 GAS INSTALLATIONS IN TIMBER FRAME BUILDINGS...
5. INSTALLATION OF HEATER 1. Lift the bottom of the case slightly to clear the fixing nuts and slide it upwards to free it completely. Put the case to one side. Remove the two screws from the dressing strip and put that to one side also. Place the heater face down on the packing (Fig.
6. CONNECTION TO GAS SUPPLY 1. Extend the gas supply to a convenient point beneath the heater and connect it to the inlet of the gas control at the right hand side of the heater. 2. A union service tap must be fitted adjacent to the heater to facilitate servicing (for neatness, fit it beneath the heater where possible).
2. THERMOSTAT CONTROL 1. Slacken the tubing nuts at the inlet and outlet of the thermostat body. 2. Slide the thermostat phial out of the case fixing bracket behind the back panel at the lower L.H. corner, pull down the r.h. end and slide it out of it’s locating clip. 3.
4. PILOT ASSEMBLY 1 .Disconnect the electrode lead from the spark electrode and unwind it from the pilot tube. 2. Release the tubing nuts at each end of the pilot supply tube and remove the tube taking care not to loose the injector from the pilot assembly or the gauze filter from the pilot outlet.
Page 12
9. FLAME VIEWING WINDOW 1 .Remove three screws securing the frame to heat exchanger. Take off the frame gaskets and (Broken)glass 2. Refit new window kit if required. 10. CASE The perforated panel and control panel can be replaced by removing the requisite screws.