Redline Communications RedMAX User Manual

Outdoor wireless access subscriber modem
Table of Contents

Advertisement

Quick Links

a m
RedMAX
TM
Outdoor Wireless Access
Subscriber Modem

User Manual

Proprietary Redline Communications © 2007
70-00057-01-01-DRAFT
September 7, 2007
Page 1 of 55

Advertisement

Table of Contents
loading

Summary of Contents for Redline Communications RedMAX

  • Page 1: User Manual

    RedMAX Outdoor Wireless Access Subscriber Modem User Manual Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 1 of 55...
  • Page 2 All rights reserved September 7, 2007. The information in this document is proprietary to Redline Communications Inc. This document may not in whole or in part be copied, reproduced, or reduced to any medium without prior consent, in writing, from Redline Communications Incorporated.
  • Page 3: Table Of Contents

    Mounting the Outdoor Subscriber ............24 3.4.1 Outdoor Subscriber with Integrated Antenna ........24 3.4.2 Outdoor Subscriber with External Antenna ......... 25 3.4.3 Antenna Alignment ................25 CLI Commands ..................26 Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 3 of 55...
  • Page 4 Subscriber Log Messages ............... 48 Upgrade Subscriber ................52 5.4.1 FTP Server ..................52 5.4.2 Upgrade Path ..................52 5.4.3 Connection to Subscriber ..............52 5.4.4 Update Software Procedure ..............53 Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 4 of 55...
  • Page 5 SU-O User Manual LIST OF FIGURES Figure 1: Notices - WEEE Logo ................12 Figure 2: Intro - RedMAX Subscriber Outdoor System ........14 Figure 3: System - PTP Line of Sight Deployment..........16 Figure 4: System - Fresnel Zone................. 17 Figure 5: System - Non-Line of Sight Deployment ..........
  • Page 6 Table 23: CLI - status - Status Commands ............45 Table 24: Specifications - Outdoor Wireless Subscriber Modem ......46 Table 25: Reference - RedMAX Subscriber Receive Sensitivity......47 Table 26: Troubleshooting - Event Log Messages..........48 Proprietary Redline Communications © 2007...
  • Page 7: Important Safety Notices

    Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing. Electro-Magnetic Radiation High Voltage Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 7 of 55...
  • Page 8: Csa Information

    Type Polarization Vertical or A2014ARF 13.5 3.3 - 3.8 Panel Horizontal 16.5 3.3-3.4 Vertical or A1815MTS 18.5 3.4-3.7 Panel Horizontal 3.7-3.8 Vertical or A2408MTF 3.3-3.8 Panel Horizontal Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 8 of 55...
  • Page 9: Fcc Notice

    3.3 - 3.8 Horizontal Panel 600 x 600 Vertical or A2408MTF 3.3-3.8 Panel Horizontal 16.5 3.3-3.4 305 x 305 Vertical or A1815MTS 18.5 3.4-3.7 Panel Horizontal 3.7-3.8 Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 9 of 55...
  • Page 10: Frequency Selection

    1999/5/CE Par la présente, Redline Communications déclare que ce subscriber est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables Proprietary Redline Communications ©...
  • Page 11 Redline Communications declara que este subscriber está conforme com os requisitos essenciais e outras provisões da Directiva 1999/5/CE. Spanish Por medio de la presente Redline Communications declara que el subscriber cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE Swedish Härmed intygar Redline Communications att denna subscriber står I...
  • Page 12: Weee Product Return Process

    Figure 1: Notices - WEEE Logo In accordance with the WEEE (Waste from Electrical and Electronic Equipment) directive, 2002/96/EC, Redline Communications equipment is marked with the logo shown above. The WEEE directive seeks to increase recycling and re-use of electrical and electronic equipment.
  • Page 13: Important Service Information

    Installation Guidelines manual (70-00068-01-XX). Refer to the Redline Limited Standard Warranty and RedCare service agreements. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 13 of 55...
  • Page 14: Overview

    Chapter Congratulations on your purchase of the Redline WiMAX Forum Certified™ subscriber wireless broadband product. Redline Communications is a world leader in design and production of WiMAX and proprietary Broadband Fixed Wireless (BFW) systems. The outdoor subscriber is carrier class high-speed IEEE 802.16-2004 WiMAX compliant for point-to-point (PTP) and point-to-multipoint (PMP) deployment.
  • Page 15: Features

    (PHY) layers. Note that the 802.16-2004 standards are subject to amendment, and the subscriber product design compliance applies to a specific revision of the standard. The RedMAX product does not support mesh communication, but does support subscriber-to-subscriber communication using TLS.
  • Page 16: Reed Solomon Error Correction

    Fresnel zone of the direct path. An OLOS link has obstructions within 60% of the first Fresnel zone, but a visible path exists from the base station to the subscriber. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007...
  • Page 17: Channelization

    The subscriber divides the available frequency band into channels. Allocation of channels during deployment is dependent on spectrum availability in the licensed FWA band (3400-3600 MHz) and local licensing requirements and conditions. Channel selection Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007...
  • Page 18: Service Flows

    VLAN tag. All classification is defined at the base station and the classification parameters are downloaded to the subscriber. RedMAX supports service flows with different classification types including: 802.3 Ethernet, 802.1Q VLAN, IPV4, IPV4 Over 802.3 and IPV4 Over 802.1Q -- with options to classify based on Source and Dest of MAC and IP addresses, VLAN tag and Vlan priority, Src and Dst port number, TOS Value and Ethernet protocol type.
  • Page 19: Downlink Service Flow Scheduling

    Downlink Service Flow Scheduling The base station schedules downlink traffic on active service flows based on the minimum reserved data rate (CIR), traffic priority, and maximum latency. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 19 of 55...
  • Page 20: Outdoor Subscriber Features

    ™ Subscriber Modem SU-O User Manual Chapter The RedMAX subscriber can be deployed with an integrated antenna or an external antenna. Integrated Antenna (SU-OIA) This subscriber with integrated antenna consists of an outdoor radio (transceiver and antenna) and an indoor power-block with network connections. The subscriber electronics are housed in a weatherproof aluminum alloy case.
  • Page 21: Non Integrated Antenna (Su-Orf)

    Optional SU-OIA equipment includes: - Outdoor Ethernet cable with weatherproof connector - Indoor Power over Ethernet (PoE) power adaptor with AC power cord (NA/UK/EU) - Lightning/surge protection Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 21 of 55...
  • Page 22: Subscriber Connections And Controls

    A ground terminal is located on the rear of the subscriber. Use this screw to terminate the ground wires. Correct grounding is very important for safe operation of wireless equipment. Ensure that all grounding connections are in accordance with local and national standards. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 22 of 55...
  • Page 23: Poe (Power Over Ethernet) Power Adaptor

    Figure 9: Optional Redline-Supplied PoE (Power-over-Ethernet) Power adaptor Table 4: System - Ethernet Data Port Link/Act LEDs Port Power Output Solid Connected Power is active Blink Not connected Out of range Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 23 of 55...
  • Page 24: Mounting The Outdoor Subscriber

    ™ Subscriber Modem SU-O User Manual Mounting the Outdoor Subscriber Refer to the RedMAX Installation Guide (P/N: 70-00059) for detailed instructions. 3.4.1 Outdoor Subscriber with Integrated Antenna The SU-OIA has an integrated flat panel antenna. The vertical mount bracket can accommodate a flat vertical surface or 2.45 - 11.45 cm (1 - 4 ½...
  • Page 25: Outdoor Subscriber With External Antenna

    The signal will sound infrequently when a low signal is detected, and more often as the signal strength increases. Refer to the outdoor subscriber Installation Guidelines for detailed information. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007...
  • Page 26: Cli Commands

    Exit [ENTER] or CTRL-Z (hold down the CTRL key and depress Z) Exit from a CLI session by typing: logout [ENTER] The system prompts for logout confirmation. Depress 'Y' to complete the logout process. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 26 of 55...
  • Page 27: Root Commands

    Exit the current Telnet session. collectRadio Factory test only. reboot Reset the system. Confirmation is required. shell Factory test only. CTRL-Z Return to root mode. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 27 of 55...
  • Page 28: Mode Commands

    Display /modify the RF configuration. Enter a new values for parameters. show Display current parameter settings. softwareUpgrade Upgrade software and select the active version. status Display the Management Status. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 28 of 55...
  • Page 29: Boardconfig - Board Setup Commands

    Structure --- <<SS Mmgt Board Configuration Parameter>> Transmit Receive Others ------------------------------ ------------------------------ ---------------- IfFreq: 44000000Hz IfFreq: 44000000Hz RefOscFreq: 32000000Hz SpectrumInv: disabled(0) SpectrumInv: disabled(0) RfType: SMI(3) IfPresent: IF_Present(1) Buzzer: disabled(0) DebugLog: disabled(0) Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 29 of 55...
  • Page 30: Bsidtable - Base Station Id Table Commands

    2. New “Detected BS table reset” log message generated when any of the modifications described above occur. 3. New “Add detected BS…” log message added any time a new BS is added to the table during the initial scan process. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 30 of 55...
  • Page 31: Diagstatistics - Diagnostic Statistics

    Show Frequency Offset group of statistics. other: Show Others group of statistics. reset Set all parameters to the last measured value. Can also be applied to groups of statistics (i.e., tx group). Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 31 of 55...
  • Page 32 --------------------- --------------------- RssiMin:...-16.8 dB RssiMin:...-49.6 dB CompMin:..0 OffsetMin:..-1 RssiMax:...-15.8 dB RssiMax:...-48.6 dB CompMax:..0 OffsetMax:..4 RssiAvg:...-16.2 dB RssiAvg:...-49.0 dB CompAvg:..0 OffsetAvg:..0 RxCalStatus:...1 TxCalStatus:...1 Others --------------------- MacResets:..0 CRCErrors:..0 HeaderErrors:..0 Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 32 of 55...
  • Page 33: Ethtag - Ethernet Tagging

    Display the current setting for all parameters. For example: Structure --- <<SS Ethernet Tagging Data>> Active:.....inactive(0) Priority:...0 FilterOn:..0 PriorityCopy...0 Value:....0 Note: The base station passes all ingress and egress traffic without modification. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 33 of 55...
  • Page 34: Installedver - Installed Version

    1: Partition 0 will be loaded at reboot. For example: Partition #0 Partition #1 Others ------------------------ ------------------------ ------------------------ MajorNumber:..1 MajorNumber:..1 Active:...1 MinorNumber:..0 MinorNumber:..0 ReleaseNumber:..100 ReleaseNumber:...98 Designation:..1 Designation:..1 Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 34 of 55...
  • Page 35: Ipaddress - Ip Address Commands

    IP by 1) making the lease timeout indefinite, or 2) creating a static address reservation for your subscriber (if your DHCP server supports these features). Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007...
  • Page 36: Loadimage - Download And Activate Software Image

    Opening FTP connection..Done Downloading image ....................……………… Done Programming update..Done Erasing setup partition. Done. Writing setup partition. Done. Erasing boot block. Done Programming boot block. Done Flash programming complete. SUO#>reboot Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 36 of 55...
  • Page 37: Modthresh - Modulation Threshold

    Structure --- <<Modulation Rate Threshold Parameters>> Rate1Exit:..9.50 dB Rate1Entry:..10.50 dB Rate2Exit:..12.00 dB Rate2Entry:..13.00 dB Rate3Exit:..16.50 dB Rate3Entry:..17.50 dB Rate4Exit:..19.50 dB Rate4Entry:..20.50 dB Rate5Exit:..23.00 dB Rate5Entry:..24.00 dB Rate6Exit:..26.00 dB Rate6Entry:..27.00 dB Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 37 of 55...
  • Page 38: Monitor - Monitor Mode

    56642560 60824 304083 DlHCrcErrCount: DlCrcErrCount: UlByteCount: UlSduCount: UlMpduCount: 118122579 117162 56187 TotalHCrcErrors TotalCrcErrors TotalTxBurstCnt: TotalRngReqcnt: TotalBwReqCnt: 145145 34917 TotalMgmSentCount: TotalPaddingCount: RfRssi: TxPower: LinkStatus: 135617 -49.3 -4.3 Registered(1) Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 38 of 55...
  • Page 39: 4.3.10 Phyconfig - Physical Layer Configuration

    Display the current setting for all parameters. For example: Structure --- <<SS Mmgt PHY Configuration Parameter>> Bandwidth:..3500 kHz FftSize:....256 PsDuration:..1000 PsPerOFDMSymbol:..68 SmplFactorNum:..8 SmplFactorDen:..7 nsec CyclicPrefix:..16 PS Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 39 of 55...
  • Page 40: 4.3.11 Privacyss - Privacy Commands

    Table 18: CLI - reset - Reset Commands Command Description detectedBS Clear all entries and associated settings from the detectedBS table. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 40 of 55...
  • Page 41: 4.3.13 Rfconfig - Rf Setup Commands

    If the subscriber is unable to register with any detected base station, the scan is repeated. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007...
  • Page 42: 4.3.14 Set - Set Commands

    1 -- Full. managedSS The managedSS command allows you to configure the subscriber for independent operation, or enable management using the RedMAX EMS system. The managedSS parameter is controlled from root mode. The following table lists all commands available for managedSS.
  • Page 43: 4.3.15 Show - Show Commands

    123 Mains St. Unit #12 sysname Display the system name. Display system up time. For example: sysUpTime sysUpTime: 10 days 20:28:19 version Display the currently running software version. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 43 of 55...
  • Page 44: 4.3.16 Softwareupdate - Software Update Commands

    File Name: SUO-U1-001-01-00-078.bin Opening FTP connection..DoneDownloading image ....................…………………… ....................…………………… ..................DoneProgramming update..DoneErasing setup partition. Done.Writing setup partition. Done.Erasing boot block. DoneProgramming boot block. DoneFlash programming complete. SUO#>reboot Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 44 of 55...
  • Page 45: 4.3.17 Status - Status Information

    TotalTxBurstCount: Transmit burst. TotalRngReqCount: Ranging requests. TotalBwReqCount: Bandwidth requests. TotalMgmSentCount: Management traffic sent. TotalPaddingCount: Padding bytes sent. RfRssi: Current RSSI value. TxPower: Current Tx output power. LinkStatus: Registered(1). Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 45 of 55...
  • Page 46: Appendices

    802.16-2004 packet convergence sub-layer mode QoS (delay, CIR/PIR) Scheduled Services (UGS, rtPS, nrtPS, UPS, BE) TDMA Access Range: 20 km (13 miles) LOS 2.5 km (1.5 miles) non LOS Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 46 of 55...
  • Page 47: Receive Sensitivity

    Actual Ethernet data throughput is dependent on channel size, protocols, packet size, burst rate, transmission latency, and link distance. Receive Sensitivity The following table lists the RedMAX subscriber sensitivity levels for different modulation and coding levels. Table 25: Reference - RedMAX Subscriber Receive Sensitivity...
  • Page 48: Subscriber Log Messages

    XXXX] number of times. DSA Rejected - Service The service flow ID assigned base station already exists Flow exists [SF Id: XXXX] locally in subscriber Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 48 of 55...
  • Page 49 Large Time Adjustment An excessively large timing correction has been sent by Received the base station. This correction has not been applied, though it has been acknowledged. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 49 of 55...
  • Page 50 Correction Anomaly [TLV Not a fatal error. Map: XXXXXXXX] Rng Maintenance An adjustment requested by the base station has been Correction Success [TLV successfully applied. Map: XXXXXXXX] Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 50 of 55...
  • Page 51 [CID: XXXX, No.Cls: nn] Uplink SF nn not created The subscriber cannot create the specified UL service (no space) [CID: XXXX] flow, as there is not enough remaining memory. Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 51 of 55...
  • Page 52: Upgrade Subscriber

    The subscribers must be updated using CLI while the base station may be updated using CLI or the Web interface. If available, you may use the RedMAX RMS server provisioning features to upgrade the RedMAX software. All upgrades require an FTP server.
  • Page 53: Update Software Procedure

    Opening FTP connection..Done Downloading image ....................……………… Done Programming update..Done Erasing setup partition. Done. Writing setup partition. Done. Erasing boot block. Done Programming boot block. Done Flash programming complete. SUO#>reboot Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 53 of 55...
  • Page 54 RedMAX ™ Subscriber Modem SU-O User Manual Proprietary Redline Communications © 2007 70-00057-01-01-DRAFT September 7, 2007 Page 54 of 55...
  • Page 55 302 Town Centre • Suite 100 • Markham, Ontario • Canada • L3R 0E8 www.redlinecommunications.com Proprietary Redline Communications © 2007 Doc #70-00057-01-01-DRAFT September 7, 2007 Page 55 of 55...

Table of Contents