Saia-Burgess Controls Ltd. PCD7.D6120TV010 Hardware Manual

Pcd7.d61 series

Advertisement

Quick Links

Hardware Manual
���������������
���������������
The PCD7.D61xx series
Controls Division
Document 26/844; Version E 1 | 30.04.2006

Advertisement

Table of Contents
loading

Summary of Contents for Saia-Burgess Controls Ltd. PCD7.D6120TV010

  • Page 1 Hardware Manual ��������������� ��������������� The PCD7.D61xx series Controls Division Document 26/844; Version E 1 | 30.04.2006...
  • Page 2: Table Of Contents

    Saia-Burgess Controls Ltd. Contents Contents Document history .................... 0-2 Trademarks ..................... 0-2 Introduction Certificates and Directives ................1-2 Product description Commissioning Power supply ....................3-1 Earthing concept ..................... 3-2 Installation ....................... 3-2 Switch-on ......................3-2 Technical data Physical dimensions ..................4-1 Electrical data ....................
  • Page 3: Document History

    Saia-Burgess Controls Ltd. Contents Document history Document-no. Version Change Publication Remarks 026/844 30.04.2006 Initial version Trademarks Saia ® is a registered trademark of Saia-Burgess Electronics AG. Microsoft, Windows 2000, Windows XP, Windows CE and the Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the USA and/or other countries.
  • Page 4: Introduction

    Saia-Burgess Controls Ltd. Introduction Introduction Please read the manual before you use the controls for the first time, and keep it in a safe place for later use. Target group This manual is written for users with prior knowledge of PC and automation technology.
  • Page 5: Certificates And Directives

    Saia-Burgess Controls Ltd. Introduction Certifi cates and Directives Proper use The device may only be used for the scenarios specified in the catalogue and the technical description, and only in conjunction with third-party devices recommended or approved by Saia-Burgess Controls AG. Trouble-free and safe operation of the device depends on appropriate transport, storage, setup and assembly, as well as careful operation and maintenance.
  • Page 6: Product Description

    Saia-Burgess Controls Ltd. Product description Product description The series comprises the PCD7.D6120TV010 and PCD7.D6150TV010 models. User side Colour TFT display with resistive touch (PCD7.D6120TV010 and PCD7.D6150TV010)         Slot side  COM1/COM2  LAN1/LAN2 ...
  • Page 7: Commissioning Power Supply

    Saia-Burgess Controls Ltd. Commissioning Power supply Commissioning Power supply The PCD7.D61xx devices must only be run on functional extra-low voltage with secure insulation in accordance with EN60950. The control transformer must comply with EN60742. The supply voltage must be checked against the type plate. When wiring the power supply and the connector, the details on the type plate must be observed.
  • Page 8: Earthing Concept

    Saia-Burgess Controls Ltd. Commissioning Earthing concept / Installation / Switch-on Earthing concept To ensure that electrical faults are dealt with safely, the following points should be observed: ● Connect device and switching cabinet by the shortest route to a central earthing point.
  • Page 9: Technical Data

    Saia-Burgess Controls Ltd. Technical data Physical dimensions Technical data Physical dimensions PCD7.D6120TV010 exterior/flush mounting dimensions Front plate: Width 364.0 mm Height 296.0 mm Aperture size: Width 345.0 mm Height 277.0 mm Depth: 111.5 mm Weight: approx. 6.0 kg ��� ��� + 1.0 Type of fixing:...
  • Page 10 Saia-Burgess Controls Ltd. Technical data Physical dimensions PCD7.D6120TV010 dimensions: Blick auf die Geräteunterseite 134.8 Seitenansicht Seitenansicht Blick auf die Geräterückseite 95.5 65.5 111.5 Blick auf die Geräteoberseite Manual: PCD7.D61xx series│Document 26 / 844│Version E 1│30.04.2006...
  • Page 11 Saia-Burgess Controls Ltd. Technical data Physical dimensions PCD7.D6150TV010 exterior/flush mounting dimensions Front plate: Width 452.0 mm Height 357.0 mm Aperture size: Width 429.0 mm Height 334.0 mm Depth: 124.5 mm Weight: approx. 7.6 kg ��� 429 + 1.0 Type of fixing: 10 M4 nuts 10 M4 flat washers 10 M4 lock washers...
  • Page 12 Saia-Burgess Controls Ltd. Technical data Physical dimensions PCD7.D6150TV010 dimensions: Blick auf die Geräteunterseite 134.8 14.8 Seitenansicht Seitenansicht Blick auf die Geräterückseite 108.5 78.5 124.5 Blick auf die Geräteoberseite Manual: PCD7.D61xx series│Document 26 / 844│Version E 1│30.04.2006...
  • Page 13: Electrical Data

    Saia-Burgess Controls Ltd. Technical data Electrical data/Environmental conditions Electrical data Model PCD7.D6120TV010 PCD7.D6150TV010 Power supply Operating voltage 24 V ± 15%, reverse voltage protected Current consumption approx. 2.0 A Display unit Display diagonal (inches) 12.1 Resolution (pixels) 800x600 1024x768 Max. colours...
  • Page 14: Interfaces

    Saia-Burgess Controls Ltd. Technical data Interfaces Interfaces Compact flash slot The EPC units are fitted with a CFA standard (type 1) compact flash slot as standard.  Position of compact flash slot  Ejection lever Only compact flash cards from SANDISK may be used in conjuction with the EPC. The compact flash card should only be changed with the device switched off.
  • Page 15 Saia-Burgess Controls Ltd. Technical data Interfaces Ethernet, USB, PS/2   Ethernet 1 / 2 (RJ45)    USB 1 / 2  PS2 mouse/keyboard PS/2 mouse and keyboard may only be plugged or removed with the unit switched off.
  • Page 16: Maintenance And Support

    Saia-Burgess Controls Ltd. Maintenance and support Battery changing/instructions for touch screens Maintenance and support Battery changing The devices are fitted with an integrated lithium battery for data buffering. Battery type: CR2032, 3V / 230mAh Manufacturer: e.g. Varta, type 6032 Buffer current: 2µA typ.
  • Page 17: Appendix 6.1 Icons

    Saia-Burgess Controls Ltd. Appendix Icons Appendix Icons In manuals, this symbol refers the reader to further information in this manual or other manuals or technical information documents. As a rule there is no direct link to such documents. This symbol warns the reader of the risk to components from electrostatic discharges caused by touch.
  • Page 18: Address Of Saia-Burgess

    Saia-Burgess Controls Ltd. Appendix Address Address of Saia-Burgess Saia-Burgess Controls AG Bahnhofstrasse 18 CH-3280 Murten / Switzerland Tel: +41 26 / 672 71 11 Fax: +41 26 / 672 74 99 E-mail: pcd@saia-burgess.com Home page: www.saia-burgess.com Support: www.sbc-support.ch Manual: PCD7.D61xx series│Document 26 / 844│Version E 1│30.04.2006...

This manual is also suitable for:

Pcd7.d6150tv010

Table of Contents