Home ventilation with heat recovery mobile operating hours reader from the meltem m-wrg series (12 pages)
Summary of Contents for Meltem M-WRG-FBH
Page 1
HOME VENTILATION WITH HEAT RECOVERY Wireless remote control M-WRG-FBH Part no. 5302-25-01 Week 04/2017 EN VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
“Extract air operation” program ..................20 “Humidity control” program ..................... 21 VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Page 3
“Continuous operation” program ..................22 “Intensive ventilation (15 min)” program ................. 22 Device settings ....................... 22 Operating the ventilation unit with the wireless remote control M-WRG-FBH ..23 Select ventilation program ....................23 9.1.1 Graphical illustration of the steps to select a ventilation program ........23 Temporarily set ventilation levels in manual mode ............
Page 4
V E N T I L AT I O N & H E AT R E C O V E R Y VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com ·...
When operating the ventilation unit, also follow the operating instructions that were sup- plied with your unit. Description This user guide describes how to set up and operate the M-WRG-S/Z-T(-F,-FC) decentralised ventilation units (see Fig. 1) with the M-WRG-FBH wireless remote control (see Fig. 2). Fig. 1: M-WRG-S/Z-T(-F,-FC) ventilation unit Fig. 2:...
V E N T I L AT I O N & H E AT R E C O V E R Y Target group This user guide is intended for users of the M-WRG-FBH wireless remote control. No special prior knowledge is needed.
The regulations and statutory requirements in your own country concerning disposal should also be followed. Revision index Edition Manual Date edition User guide for wireless remote control M-WRG-FBH Week 04/2017 EN 1.10 Explanation of the symbols used ► This symbol indicates an action to be taken. —...
Do not allow children to play with the unit. Cleaning and VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com ·...
— The ventilation unit must not be operated without air filters. — For any use contrary to the intended use, Meltem Wärmerückgewinnung GmbH & Co. KG shall accept no liability for any damage that may occur and offers no warranty that the components will work perfectly and correctly. Warranty and liability...
V E N T I L AT I O N & H E AT R E C O V E R Y Controls and displays Buttons and LCD display The M-WRG-FBH wireless remote control has four buttons and an LCD display that provides infor- mation on the operating status. The buttons perform multiple functions. Fig. 3:...
Symbol for the “Extract air operation” ventilation program. Flashes when activated. VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Page 12
Table 3: Symbols on the LCD display VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 12 -...
Remove battery compartment cover Fig. 6: Insert batteries in battery compartment VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 13 -...
The LCD display shows the following information: Fig. 10: Connect new ventilation unit The dot in the top left corner flashes to indicate that ventilation unit 1 can be connected. VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 14 -...
Page 15
3 seconds, the Connection menu appears (see Fig. 8 on page 14). VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
This will allow you to check that you have selected the right venti- lation unit and that it is within range. VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Page 17
3 seconds, the Connection menu appears (see Fig. 14 on page 16). VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Fig. 22: Display mode – Ventilation programs VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 18 -...
6.2 on page 14). Fig. 25: Display mode – Connection mode VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
5-minute period. If the corresponding limit is exceeded, the ventilation unit switches back to ventilation mode. VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Device settings Symbol Default view Description This menu is used to read, configure and permanently store the ventilation program parameters and device-specific settings. – VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 22 -...
Fig. 27: Select ventilation program with wireless remote control (e.g. continuous operation) VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
— Ventilation level for same time. extract air VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 24 -...
Fig. 28: Configure and permanently save active ventilation program (e.g. mixed gas/CO program) VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 26 -...
Table 5: Overview of the variable parameters in the active ventilation program VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Fig. 29: Changing parameters in the Device settings menu VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
0: Control for Standby mode for mixed gas/CO active control VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 30 -...
Page 31
(3) Hold down the button to scroll through the values faster VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
► Hold down the button for more than 3 seconds to reset the filter change indicator. You will find more details on filter maintenance in the operating instructions for your venti- lation unit. VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com - 32 -...
— If there are multiple ventilation units of the same type connected to one M-WRG-FBH wire- less remote control, the same ventilation program is activated for all the ventilation units. — If multiple ventilation units of the same type with humidity and/or mixed gas/CO...
Remedy Fault in the ventilation Have the ventilation unit The symbol is displayed on the unit (e.g. faulty sensor or repaired by Meltem or by an wireless remote control. motor) authorised specialist company No wireless connection to — Reduce the distance be-...
Page 35
V E N T I L AT I O N & H E AT R E C O V E R Y Space for notes VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Need help?
Do you have a question about the M-WRG-FBH and is the answer not in the manual?
Questions and answers