WARNINGS AND CAUTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user the presence of non-insulated “dangerous voltage”...
Page 3
PRECAUTIONS: l Persons without technical qualifications should not attempt to operate this dome device before reading this manual thoroughly. l Remove any power to the dome before attempting any operations or adjustments inside the dome cover to avoid potential damage to the mechanism. l Inside the dome cover there are precision optical and electrical devices.
IMPORTANT SAFEGUARDS 1. Read these instructions before attempting installation or operation of dome device 2. Keep these instructions for future reference 3. Heed all warnings and adhere to electrical specifications Follow all instructions 4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners 5.
1.2 Specification Speed Dome High Speed Dome Medium Speed Dome Horizontal Rotation Speed 200°/s 60°/s Tilt Rotation Speed 100°/s 30°/s Horizontal Rotation Range 360° Tilt Rotation Range 93° Auto Flip Horizontal 180°, Vertical 93° Auto Control IR LED A-B Scan User programmable A-B Scan Speed 01-64speed setting available...
1.3 Function Description Super Communication Address, baud rate and protocol could be changed from OSD. Privacy Mask Depend on the zoom nodule. This function allows user to set privacy protected area as unviewable in the monitoring scope. Alarming Set The dome support this feature in optional , details please refer to the OSD menu. IR Detection Time Time duration switching from Color to B/W or B/W to Color.
Page 10
Day/Night Switch With auto day/night switch function, when the illumination is low the picture will auto switch from day to night mode and when the illumination is high enough the picture will auto switch from night to day mode Ratio Speed Intelligent pan and tilt speed is variable depend on the zoom factor.
2 Installation 2.1 Coaxial Control The dome supports coaxial control and also supports RS-485 communication signal. 2.1.1 AC24V power cable transmission distance and cable requirement In general, the power cable has resistance, there are internal losses when transmitting the voltage, the longer of the cable used, the smaller the wire diameter, the worse loss will suffer. In order to avoid losses of cable causing low voltage and keep the dome work properly, when processing wiring please refer to the requirement below: Cable diameter 0.5mm ²...
2.3 Installation of Brackets. 2.3.1 Wall Mounted Fig 1 Installation conditions: Wall mounted dome can be used in the hard wall structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment. The wall can bear at least 4 times the weight of the dome.
2.3.2 Corner Mounted Fig 11 Installation conditions: Corner mounted dome can be used in the hard wall structure with an angle of 90° whose thickness should be enough to install expansion bolt in indoor and outdoor environment. The wall can bear at least 4 times the weight of the dome. Install corner mounted attachment and wall hanging bracket: a.
c. As shown in fig 14, fix the wall hanging bracket with all cables power through it on the corner mounted attachment. Fig 14 2.3.3 Pole Mounted Fig 15 Installation conditions: Pole mounted dome can be used in the hard pole structure in indoor and outdoor environment whose diameter should match the installation size of stainless hose clamps.
b. As shown in fig 17, fix the wall hanging bracket with all cables through it on the pole mounted attachment. Fig 17 2.3.4 Ceiling Mounted Installation conditions: Ceiling mounted dome with thick pole can be used in the hard ceiling structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment.
b. As shown in fig 20, at first unscrew the M4 screw at the side of the base of ceiling and split the base of ceiling and boom. Then make the three groups of cables of power, video/control and alarming into the side recessing seal groove of the ceiling connector bottom and through the core hole of the base of ceiling mounted.
3. Function Instruction 3.1 Power Up Action <SYSTEM> <SYSTEM> PROTOCOL AUTO PROTOCOL AUTO DOME ID DOME ID COMM COMM VERSION VERSION TEMPERATURE TEMPERATURE DETECTING… PAN: XXX TILT: XXX Power Up Self Testing Pan, Tilt, Camera Self-test Completion ² Pan action: Pan rotate in certain direction and stop in zero coordinate. ²...
Overview for 4 in 1 products(Support AHD/ CVI/ TVI/ CVBS output) Basic on single HD Analog coaxial series,( AHD/TVI/CVI/CVBS series), the 4 in 1 series have combined the 4 single output signal together,it can be switched the video signal freely between the AHD/TVI/CVI/CVBS by shortcut commends.
signal, the TV system ( NTSC/Pal) between the PTZ and the controlled equipment to be consistent, if not, please adjust accordingly. 3.4 Screen Character Operation Call preset 95 to enter the OSD, call preset 94 to exit the OSD. ² Up or Down: Move the option of the OSD, change the set point. ²...
4.2 System Information <MAIN MENU> <SYSTEM> <DOME> <CAMERA> <LANGUAGE> <DISPLAY> <RESET> EXIT Get into the Menu Screen <SYSTEM> PROTOCOL AUTO DOME ID COMM 2400.N.8.1 VERSION TEMPERATURE EXIT MFG: Max 15 characters displayed on the screen. PROTOCOL: Display the protocol of the dome DOME ID: Display the dome address COMM Form: Baud rate.
4.3.1 Communication <COMM> <COMM RESET> DEVICE ID RESET TO DIAL THE CODE CHECK ID 000000 TARGET ID SOFT PROTOCOL AUTO BAUD RATE 2400BPS <COMM RESET> SAVE EXIT EXIT DEVICE ID: It is sole and auto generated by system. CHECK ID: To change the TARGET ID, please input the CHECK ID exactly same as the DEVICE ID displays on the screen.
auto IR working mode, if the illumination on level is less than the ambient light, the picture will change to color, the IR illumination will turn off automatically. If the illumination on level is more than the ambient light, the picture will change to black , the IR illumination will turn on automatically.
DWELL TIME: Dwell time between A to B is 2s to 60s selectable. RUNNING: Running the A-B scan. Check Fig. 4.3.4.2. DELETE: After deleted, the preset points of A and B display as 0. While the exact preset point information doesn’t be deleted. So it is convenient for user to select the preset point needing to be scanned.
4.3.7 Privacy Zone <PRIVACY ZONE> <PRIVACY ZONE> <PRIVACY ZONE> MASK NO. MASK PRIVACY PROPOSED <SETTING> TO OPEN PRESET 1: SAVE EXIT MASK NO.: Mask No. depends on the number of the module supported. The selective range of Sony is from 1 to 24. MASK: Mask has on and off selectable.
RELEASE TIME: Alarming release time, 2-60s selectable, the default is OFF. 4.3.9 Advanced <ADVANCED> PWR ON ACTION MEMORY RATIO SPEED AUTO FLIP WIPER MODE WIPER SPEED WIPER TIMES <OTHERS> EXIT PWR ON ACTION: Power on action can be set as Memory, A-B scan, Pan scan, Park action, Guard tour 01, Guard tour 02, Guard tour 03 and No action.
Remark: Only if those functions are available on the present module, the user can use them. 4.5 Language <LANGUAGE> LANGUAGE ENGLISH EXIT LANGUAGE: Language can be set as Chinese or English. Default settings is English. 4.6 Display <DISPLAY> SYSTEM P AND T ACTION DOME ID COMM...
<PRESET> CONFIRM: DEL ALL PRESETS CONFIRM 1: DEL 01 TO 16 CONFIRM 2: DEL 17 TO 32 CONFIRM 3: DEL 33 TO 48 CONFIRM 4: DEL 49 TO 64 EXIT CONFIRM: Delete the presets information saved by the dome. 5. Auto Temperature Control This product has built-in fan and heater, which accordingly cool or heat through temperature sensitive circuit inside the dome.
grounding conductor must be not less than 25mm Fig 1 Appendix Ⅱ Clean Transparent Cover In order to assure a clear image of dome, the under cover of dome should be cleaned regularly. l Be careful when cleaning and hold the outer ring of under cover by hands to avoid directly touching with it.
Fig 2 Fig 3 2.2 120Ω terminal resistance is connected as shown in fig 2. 120Ω terminal resistance is available in the circuit board and the connection is shown as following: When needing to connect 120Ω resistance, toggle the 8 bit of DIP switch SW2 to "ON"...
Copyright Statement This copyright is merely belong to the manufacturer. Without permission, please don’t plagiarize or copy the contents of this book in any form or by any means. The company follows the policy of continuous development. Therefore, the company reserves the right to modify or improve the products described in this manual without notice.