Aeroel HWS.1 User Manual

Handy wire scanner

Advertisement

VALIDAZIONE
AEROEL s.r.l. - via Pier Paolo Pasolini 35/3, 33040 - PRADAMANO (UD) - ITALY -  +39 0432 671301 (
Handy Wire Scanner
HW 240HW01V00
SW 600V00L02
ANNULLAMENTO
http://www.aeroel.it
e-mail: aeroel@aeroel.it
HWS.1
USER'S MANUAL
ENGLISH
B2798_E – 1.1
numero DTE:
B2798_E – 1.0
foglio: 1 di tot: 36
Rif.: 240HW01V00
Redatto: PS
Ai sensi di legge, il contenuto
di questo documento non può
essere riprodotto o comunicato
a terzi senza approvazione
scritta di Aeroel s.r.l.
671543)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HWS.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aeroel HWS.1

  • Page 1 Aeroel s.r.l. AEROEL s.r.l. - via Pier Paolo Pasolini 35/3, 33040 - PRADAMANO (UD) - ITALY -  +39 0432 671301 (  671543) http://www.aeroel.it...
  • Page 3: Table Of Contents

    HWS.1 Handy Wire Scanner - 240HW01V00 INDEX PRELIMINARY INFORMATION ......................... 5 THANKS ................................. 5 WARRANTY TERMS ............................... 5 CONFORMITY TO THE NORMATIVES IN FORCE ..................... 6 SAFETY INFORMATIONS ............................6 GENERAL SAFETY RULES ............................6 SPECIFIC SAFETY PROVISIONS ..........................7 INTENDED USE ..............................
  • Page 4 AEROEL s.r.l. - PRADAMANO (UD) - ITALY B2798_E 1.1, 2016-04-08...
  • Page 5: Preliminary Information

    PRELIMINARY INFORMATION THANKS We wish to thank you and to congratulate you for choosing an AEROEL product. We are sure that you will fully appreciate the reliability and the accuracy that our equipment can grant. We did our best effort to give you a top quality product, by carefully selecting the employed components and by adopting strict quality control procedures, both during the assembling and the final testing.
  • Page 6: Conformity To The Normatives In Force

    / or serious injury. Save all warnings and instructions for future reference. In this manual, the measuring instrument HWS.1 - Handy Wire Scanner will be hereinafter referred to as "HWS.1" or "scanner" or "instrument" or "gun" While using the instrument used the precautions described in the following chapters...
  • Page 7: Specific Safety Provisions

    Have your equipment serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the tool is maintained. SPECIFIC SAFETY PROVISIONS To use safely the HWS.1 - Handy Wire Scanner, please follow the special precautions listed below: Measuring moving parts •...
  • Page 8: Intended Use

    HWS.1 portable micrometer as a "fail-safe" device; • use of the HWS.1 portable micrometer on transport means, in life support devices and in any other system in which any malfunctioning of the micrometer could provoke direct or indirect damage to human life.
  • Page 9: Equipment Disposal

    Should a new piece of equipment be purchased to replace a similar one manufactured by Aeroel, within the European Union, Aeroel may take-in the used equipment and dispose of it in compliance with the laws in force in matters of waste disposal without any additional cost to the Customer, except for transport costs (from the Customer’s site to...
  • Page 10: Technical Info

    The software "YesWeGun" for PC Windows is available in the CD-ROM supplied with HWS.1. The program allows the management of HWS.1 connected to a PC via an USB cable. This software is the only tool that allows communication between HWS.1 and a PC.
  • Page 11: Description

    HWS.1 Handy Wire Scanner - 240HW01V00 DESCRIPTION Main parts Display Product being Upper optics measured Function keys Functio Lower optics Safe/Arm Handle Connector Trigger Info and CE marking USB Connector Fixing holes Magnets Display Reference sphere Optical prisms Function keys...
  • Page 12: Protection

    AEROEL s.r.l. - PRADAMANO (UD) - ITALY PROTECTION HWS.1 is supplied with removable protections for the optics and for the operator’s hand. Protection for Protection for optics optics Handguard Handguard The optics protection is useful to protect the surface of the optical prisms against any accidental contact with the product.
  • Page 13: Portable Tag (Optional)

    In this part, when positioned horizontally, insert the scanner HWS.1 for measurement. The movable part can be locked by means of a retaining screw.
  • Page 14: Pulley Set For Wire Guidance, With Adjusting Wheel (Optional Device)

    Attention! The positioning of the fixture must be done in order to allow easy access for the measurement without risks for the operator. For instructions, please contact the customer service Aeroel Attention! For the dimensions of the mounting holes see drawing in Appendix ...
  • Page 15 HWS.1 Handy Wire Scanner - 240HW01V00 Follow the instructions below: Fix the rail  on-line, in a suitable position, depending  upon the wire axis position To get the rail dimensions please check the drawing above Insert from the bottom the pulley assembly ...
  • Page 16: Front Pulley For Wire Guidance (Optional Device)

    CHARGING THE BATTERY HWS.1 is equipped with a rechargeable lithium-ion cell, PANASONIC NCR18650B, 3.6V, 3350 mAh, 12 Wh capacity. At first use, the battery should be fully charged and you should fully charge the battery before any prolonged use of the instrument.
  • Page 17: Turning On And Off

    The charging time with the charger supplied (1500 mA) is about 3 hours. To be recharged, HWS.1 can also be connected to the USB socket of a PC (500 mA), in this case the duration of the full charge is approximately 8 hours.
  • Page 18: Automatic Switch Off

    The hour "flashes" on first use when no setting has not been made, or in the case of complete battery discharge. For information on setting the time and date:  PLEASE REFER TO CHAPTER 2.15 HWS.1 SETUP B2798_E 1.1, 2016-04-08...
  • Page 19 - Offset icon Icon shown when an offset value has been programmed in the Calibration menu Icon offset active  PLEASE REFER TO CHAPTER 2.15 HWS.1 SETUP  - Glass Logic Icon Icon shown when enabled the Glass Logic for the measurement of transparent products Icon Glass Logic active ...
  • Page 20: Setup Menu

    AEROEL s.r.l. - PRADAMANO (UD) - ITALY  - Measured value box In the box it is shown the measured value and the directions about the vertical position and the alignment of the product No product in the measuring field...
  • Page 21: Measure Setup

    HWS.1 Handy Wire Scanner - 240HW01V00 2.14 MEASURE SETUP Selecting the Measure Setup you enter the menu that enables you to set some parameters and options for the measure and its visualization. using the arrow keys  (F2 and F3) and the Enter key (F1).you can select the following items: •...
  • Page 22: Hws.1 Setup

    2.15 HWS.1 SETUP Selecting the HWS.1 Setup you enter the menu that allows you to adjust some settings of the instrument. Using the arrow keys  (F2 and F3) and the Enter key (F1), you can select the following items: •...
  • Page 23 HWS.1 Handy Wire Scanner - 240HW01V00 • Power Management It Is used to select the downtime after which the instrument is switched off automatically  PLEASE REFER TO CHAPTER 2.10 AUTOMATIC SWITCH OFF Selecting with the Enter key (F1) you access the item Power Off and selecting again the entry with the Enter key (F1) you access to the choice of the no-activity time (downtime) that must pass before the instrument will automatically switch off.
  • Page 24: Measuring A Product

    MEASURING A PRODUCT GENERAL INDICATIONS HWS.1 performs the continuous measurement of a product when it is positioned correctly in the measuring field with a short sampling time (approximate measurement). This allows you to immediately view the product centring and alignment indications. When positioning is correct, the diameter value appears on the display in a green box.
  • Page 25 The following indications show the meaning of the indications on the display with respect to the relative positioning between HWS.1 and the product to be measured. For measurement to be possible, the product must be within all three required centering and alignment parameters.
  • Page 26 AEROEL s.r.l. - PRADAMANO (UD) - ITALY Signaling product inside the horizontal measurement field (measurement possible): Product inside external Product centered in Product inside internal limit limit of horizontal horizontal measurement of horizontal measurement measurement field field field 2. Vertical centering of product The display indicates the vertical centering status of the product by "splitting"...
  • Page 27: Averaging Mode

    HWS.1 Handy Wire Scanner - 240HW01V00 Signaling product inside the vertical measurement field (measurement possible): Product centered in the vertical Product centered in vertical measurement field, but not and horizontal measurement centered horizontally: the box field: The diameter reading is...
  • Page 28: Glass Logic

    AEROEL s.r.l. - PRADAMANO (UD) - ITALY The available averaging mode are 4: Fast+ e Fast They are the two fastest averaging modes. When the trigger is pulled with the product in the measurement field, valid scans are acquired for a time of 0.01 sec. (Fast +) or 0,05 sec. (Fast).
  • Page 29: Measuring A Product

    HWS.1 Handy Wire Scanner - 240HW01V00 MEASURING A PRODUCT As described above, HWS.1 continuously measures a product when it is positioned correctly in the measurement field and displays the centering and alignment indications of the product itself. When positioning is correct, the diameter value appears on the display in a green box.
  • Page 30: On-Line Measurement With Fixture Device (Optional)

    5. At the end of the measurement, the instrument emits a long beep and the measurement remains displayed for the time equal to that programmed and saved in the memory (if saving is enabled). 6. At this point release the trigger and extract HWS.1 from the housing of the fixture to perform further measurements.
  • Page 31: Offset Calibration

    When an offset value is set, this icon appears on the display To access the Calibration menu, select Setup (F1) → Setup HWS.1 → Calibration At this point the available options will be displayed: Offset, Diameter and Factory.
  • Page 32 AEROEL s.r.l. - PRADAMANO (UD) - ITALY Select the desired entry by using the arrow keys (F2 and F3) and the Enter key (F1).  To exit, restore factory calibration (resetting the offset) press Exit (F4) or select the entry Cancel and press Enter (F1).
  • Page 33: Appendix

    HWS.1 Handy Wire Scanner - 240HW01V00 APPENDIX FIXTURE DIMENSIONS B2798_E 1.1, 2016-04-08...
  • Page 34: Instructions To Remove The Battery

    AEROEL s.r.l. - PRADAMANO (UD) - ITALY INSTRUCTIONS TO REMOVE THE BATTERY When disposing of the instrument, the lithium ion battery inside the handle must be removed and separated from the rest of the equipment. To do this, follow these instructions...
  • Page 35 HWS.1 Handy Wire Scanner - 240HW01V00 For a possible repositioning of the shell you must perform the previous steps in reverse order. Remove the battery out of its housing B2798_E 1.1, 2016-04-08...
  • Page 36 AEROEL s.r.l. - PRADAMANO (UD) - ITALY B2798_E 1.1, 2016-04-08...