  • Page 1 RT‐1 Magnetic Susceptibility  Meter      USER MANUAL   Manufactured in Australia  Version 1.3 (January 2015) ...
  • Page 2 RT‐1 MAGNETIC SUSCEPTIBILITY METER   Model RT‐1   OPERATOR’S MANUAL Version 1.2 Designed & Manufactured in Australia by:    CoRMaGeo Instruments Pty. Limited A 78 Wallis Avenue, STRATHFIELD NSW 2135 AUSTRALIA +61 411 603 026 sales@cormalgeo.com.au www.cormageo.com.au     © CoRMaGeo Instruments Pty. Limited 2015  All  rights  reserved.    No  part  of  this  manual  may  be  reproduced,  copied,  stored  or ...
  • Page 3: Table Of Contents

    CONTENTS     WARRANTY………………………………………………………………….… 1    1. GENERAL INFORMATION……………………………………………. 2  2. QUICK START OPERATING INSTRUCTIONS………………….. 3  3. DESCRIPTION OF INSTRUMENT………………………………….. 5    4. PRINCIPLE OF OPERATION……………………………………….. 10    5. DEFINITIONS / USEFUL INFORMATION………………………. 11    6. DETAILED OPERATING INSTRUCTIONS……………………….. 13               ‐ BASIC OPERATION/NAVIGATION ……………………….. 13             ‐ TAKING/STORING A READING ……………………………. 15             ‐ REVIEW READINGS ……………………………………………. 17               ‐ DUMP DATA VIA  BLUETOOTH………………………….. 18  7. MENU ITEMS……………………………………………………………... 22  8. BLUETOOTH INTERFACE…………………………………………….. 27    9. TROUBLESHOOTING………………………………………………….. 28    10. CALIBRATION FREQUENCY….……………………………………...
  • Page 4: Warranty

      WARRANTY    CoRMaGeo warrants the RT‐1 Magnetic Susceptibility Meter against defective components and  workmanship for repair at the office of CoRMaGeo Instruments or authorized repair facilities free  of charge for a period of twelve (12) months from date of sale.  Shipment costs are to be borne  by the customer.  Malfunction due to improper use is not covered in this warranty.  CoRMaGeo  Instruments  disclaim  any  liability  for  consequential  damage  resulting  from  defects  in  the  performance of the equipment.  The RT‐1 is not warranted as being fit for a particular purpose  and there is no warranty of merchantability.     This warranty applies only if:  I.  The items are used solely under the operating conditions and in the manner recommended  in the RT‐1 User Manual;  II.  The items have not been misused or abused in any manner or repairs attempted thereon;   III.  Written  notice  of  the  failure  within  the  warranty  period  is  forwarded  to  CoRMaGeo  Instruments ...
  • Page 5: General Information

    February 2015  RT‐1 User Manual Ver 1.2  1.  GENERAL INFORMATION     The  RT‐1  Magnetic  Susceptibility  Meter  is  designed  to  measure  the  magnetic  susceptibility  of  rock outcrops, rock samples and drill core.    The mineral that largely governs the magnetic behaviour of a rock, and which accounts for most  of the susceptibility observed, is magnetite. The susceptibility of magnetite depends on several  factors,  such  as  the  intensity  of  the  magnetising  field,  the  chemical  composition  of  the  magnetite  and  its  grain  size.  Susceptibility  can,  however,  be  used  to  determine  the  magnetic  abundance, provided that the dependence between susceptibility and magnetic abundance is ...
  • Page 6: Quick Start Operating Instructions

    February 2015  RT‐1 User Manual Ver 1.2    2. QUICK START Operating Instructions BATTERIES    RT‐1 instruments operate on three AA batteries. Use 1.2V or 1.5V alkaline, NiMH, or lithium  batteries.    To install the batteries:  1. On the back face of the RT‐1, unscrew the two screws and remove the battery cover.  2. Insert three (3) “AA” type batteries, observing polarity.  3. Replace and screw down the battery cover.    To turn the RT‐1 on or off:  1. To turn on the RT‐1, press    Note: During startup, hold in air away from anything metallic as unit automatically zeros   2.  To turn off the RT‐1, either:  i. Press and hold    for ~2.5 sec. 3 beep alerts will sound and the RT‐1 will  power off. If   is released before the 3  beep sounds, the RT‐1 will  remain on.  OR  ii. Go to the Main Menu, press   and scroll to the “Power Off” menu item  using the arrow keys   and  , then press  .    ...
  • Page 7 February 2015  RT‐1 User Manual Ver 1.2      To zero the RT‐1:  1. Go to the Main Menu.  2. Hold the instrument clear of any magnetic or conductive material or any electronic  devices.  3. Select the “Zero” menu item and then press  .  4. You are now ready to take a reading  Note: the zeroing should take 4 seconds     To take a reading with the RT‐1:  In the Measuring screen, readings can be taken in either SCAN or STEP mode:  SCAN mode (continuous readings):  1. Place and hold the sensor end of the RT‐1 against the sample.  2. Continuous readings will be displayed on the RT‐1 screen (see Fig 4).  3. Press either the right or left black round “Measure” buttons   on the side of the RT‐1  (see Fig 1 and 2) to store a reading.  4. The reading will be displayed on the RT‐1 screen (see Fig 4).  STEP mode (individual point reading):  1. Place and hold the sensor end of the RT‐1 against the sample.  2. Press either the right or left black round “Measure” buttons   on the side of the RT‐1  (see Fig 4) to store a reading.  3. The reading will be displayed on the RT‐1 screen (see Fig 4).     ...
  • Page 8: Description Of Instrument

    February 2015  RT‐1 User Manual Ver 1.2  3.  DESCRIPTION OF INSTRUMENT     The RT‐1 is designed as a one piece instrument with a graphics display for the presentation of  the magnetic susceptibility values in both digital and analog format. An audible tone of varying  frequency related to the value allows the operator to find the peak reading using the graphical  display or the highest frequency sound and then record a digital value. It has solid‐state  memory with the ability to store readings into groups and label (with a flag) individual readings.    The RT‐1 has Bluetooth connection for transferring data to a PC computer.  UNIT LAYOUT OVERVIEW  Figure 1 Front   Figure 2 Back  CoRMaGeo Instruments  RT‐1 Manual  Page 5 ...
  • Page 9 February 2015  RT‐1 User Manual Ver 1.2  OPENING SCREEN    On start up, the RT‐1 will flash the opening screen, showing the firmware version of the unit  (Fig 3a). Following this, it will automatically “zero” (Fig. 3b) before moving to the Measuring  Screen (see next section).    Note: Always turn the RT‐1 on and perform “zeroing” in the open air, away from presence of  items with high magnetic susceptibility (see Definitions / Useful Information for more details).    a)  b)      Figure 3 a) The opening screen and b) zeroing screen  CoRMaGeo Instruments  RT‐1 Manual  Page 6 ...
  • Page 10 February 2015  RT‐1 User Manual Ver 1.2  MEASURING MENU SCREEN    The Measuring Screen is used to view and record magnetic susceptibility readings. A bar graph  indicating the strength of the magnetic susceptibility is located on the left side of the screen,  with the setup and memory parameters displayed centrally (these values can be changed using  the various menus – see following sections).   Figure 4 Measuring screen  CoRMaGeo Instruments  RT‐1 Manual  Page 7 ...
  • Page 11 February 2015  RT‐1 User Manual Ver 1.2  CONTROLS    The RT‐1 has four top push buttons associated with the operation of the menu system (control  keys) and two side push buttons (left and right) associated with taking readings (measure keys).  These are shown in Fig. 5:    a)  b)      Figure 5 a) The RT‐1 keys  and b) The RT‐1 key locations.    CoRMaGeo Instruments  RT‐1 Manual  Page 8 ...
  • Page 12 February 2015  RT‐1 User Manual Ver 1.2    FLAG SYMBOLS    A flag sets a marker next to an individual reading. Flags are useful for such things as helping to  remember readings of interest, to note bad readings or readings to recheck etc. There are 4  markers available:  Symbol  Suggested Corresponded Meaning  E   error  X   bad  C  check  i    interesting    It is important to note that once a reading has been flagged in the RT‐1 unit, the Flag cannot be  removed.      CoRMaGeo Instruments  RT‐1 Manual  Page 9 ...
  • Page 13: Principle Of Operation

    February 2015  RT‐1 User Manual Ver 1.2    4.  PRINCIPLE OF OPERATION     The function of the RT‐1 is based on electromagnetic induction. There are two coils placed  orthogonally to each other in the detector head, which is mounted in the top of the RT‐1 case.  In the non‐magnetic environment the voltage induced from the transmitter coil to the receiver  coil is zero. When a rock sample is brought near the coils, a voltage which is proportional to the  magnetic susceptibility of the sample is induced in the receiver coil. This signal is detected by a  phase‐locked amplifier and after rectification it is used to drive the circuitry for the display of  the magnetic susceptibility readings. The reading is directly calibrated for susceptibility. See Fig.  6 below.        Figure 6 Principle of operation: A 750Hz sign wave is constantly fed into the transmitter (TX)  Coil, the resulting magnetic field induces a 750Hz sign wave in the RX Coil.  The signal induced in  the receiver (RX) Coil varies due to the magnetic susceptibility and conductivity of the sample.   The magnetic  susceptibility  component  is  virtually  90  degrees  out  of  phase  to  the conductive  component.  CoRMaGeo Instruments  RT‐1 Manual  Page 10 ...
  • Page 14: Definitions / Useful Information

    February 2015  RT‐1 User Manual Ver 1.2    5.  DEFINITIONS / USEFUL INFORMATION    Operation Mode  The RT‐1 operates in two modes being continuous SCAN mode or single reading STEP mode.    SCAN mode updates the readings continuously by locating peak readings, approximately once  per second.  STEP mode takes readings only when a button is activated and essentially takes a “snap‐shot” of  the magnetic susceptibility at that point. Selecting STEP mode when storing measurements will  freeze the display with the value just stored in memory.    Bar Graph  The bar graph is a log scale to base ten (10) and is capable of showing values between 1 x 10‐5  SI units and 9.999 SI units.      Battery Replacement  The RT‐1 does not currently have a low battery warning (Firmware version 1.6H). To replace the  batteries, remove the lid on the back face of the RT‐1 by unscrewing the two screws and  replace the batteries with three (3) “AA” type batteries.    Note: In future versions of the firmware, the device will display a “low battery symbol” when  the batteries are low and an “empty battery symbol” when the batteries are exhausted.     Zeroing  The RT‐1 must be zeroed occasionally to correct for drift. This is the reference point against  which all other analytical signals will be measured. This is properly performed under the  instrument’s normal operating conditions.    CoRMaGeo Instruments  RT‐1 Manual  Page 11 ...
  • Page 15 February 2015  RT‐1 User Manual Ver 1.2  When you "zero" the RT‐1 you are telling the instrument to use the electrical output of the  sensor at the time the sensor is zeroed as the point of reference for all future readings. Change  in sensor output is then measured with respect to the output at the time the instrument was  zeroed.    Always perform “zeroing” away in the open air, away from presence of items with high  magnetic susceptibility. When you zero the RT‐1, the electrical output of the sensor at that  moment becomes the point of comparison. If the sensor is zeroed close to something with high  magnetic susceptibility then the instrument may display a false reading.    Re‐zeroing the RT‐1  When taking readings on samples of high magnetic susceptibility it may be necessary to re‐zero  the meter before taking readings again on samples of much lower susceptibility. This is due to  remnant energy being stored in the sensor coil making readings with low magnetic  susceptibility appear too high.    Drill Core Correction Factors  In general, if samples are too small so that air is sensed by the detector, the reading will be  somewhat less than the true value. How much depends on actual dimensions but it is rarely less  than half.    Correction factors for certain drill core sizes are given in Table 1.    Table 1 Drill core correction factors   CORE  DIAMETER  CORRECTION FACTOR  AQ  27mm  1.82± 0.02  BQ  33mm  1.77± 0.02  NQ  48mm  1.51± 0.02  HQ  62mm  1.44± 0.02 ...
  • Page 16: Detailed Operating Instructions

    February 2015  RT‐1 User Manual Ver 1.2  4.  DETAILED OPERATING INSTRUCTIONS    WARNING  Very strong magnetic fields can affect calibration.    IMPORTANT  Always perform “zeroing” in the open air, away from presence of items with high magnetic  susceptibility.    BATTERIES    RT‐1 instruments operate on three (3) AA batteries. Use 1.2V or 1.5V alkaline, NiMH, or lithium  batteries.    To install the batteries:  1. On the back face of the RT‐1, unscrew the two screws and remove the battery cover.  2. Insert three (3) “AA” type batteries, observing polarity.  3. Replace and screw down the battery cover.    NOTICE    Remove the batteries for shipping or when you do not plan to use the RT‐1 for several months.  Stored data is not lost when batteries are removed.    To turn the RT‐1 on or off:  1. To turn on the RT‐1, press    2.  To turn off the RT‐1, either:  CoRMaGeo Instruments  RT‐1 Manual  Page 13 ...
  • Page 17 February 2015  RT‐1 User Manual Ver 1.2  i. Press and hold    for ~2.5 sec. 3 beep alerts will sound and the RT‐1 will  power off. If   is released before the 3  beep sounds, the RT‐1 will  remain on.  OR  ii. Go to the Main Menu, press   and scroll to the “Power Off” menu item  using the arrow keys   and  , then press  .      When turned on the unit will automatically:  1. Display the start‐up screen for about 2 seconds;   2. Zero in air (~ 4 seconds);  3. Go directly into Measuring (reading) mode.    To navigate between the Measuring screen and Main Menu screen (Fig 4 and 8 respectively):  1. To move from the Measuring screen to the Main Menu screen: press   OR either of  the arrow keys   and  .  2. To move from the Main Menu screen to the Measuring screen: press  .    Navigating and Selecting the Main Menu options:  1. To navigate between the menu options, use the arrow keys   and ...
  • Page 18 February 2015  RT‐1 User Manual Ver 1.2  3. Select the “Zero” menu item and then press  .  4. You are now ready to take a reading  Note: the zeroing should take 4 seconds     To take a reading with the RT‐1:  In the Measuring screen, readings can be taken in either SCAN or STEP mode:  SCAN mode (continuous readings):  1. Place and hold the sensor end of the RT‐1 against the sample.  2. Continuous readings will be displayed on the RT‐1 screen (see Fig 4).  3. Press either the right or left black round “Measure” buttons   on the side of the RT‐1  (see Fig 1 and 2) to store a reading.  4. The reading will be displayed on the RT‐1 screen (see Fig 4).  STEP mode (individual point reading):  1. Place and hold the sensor end of the RT‐1 against the sample.  2. Press either the right or left black round “Measure” buttons   on the side of the RT‐1  (see Fig 4) to store a reading.  3. The reading will be displayed on the RT‐1 screen (see Fig 4).    Note 1: The display will indicate whether the reading is in SI or CGS units. Either can be selected  from the menu (see Settings Menu | Units below on how to change units).    Note 2: If you need to turn the RT‐1 upside‐down for this, you will notice the screen display will  flip around for ease of use!    To store a reading in the RT‐1:  Before you can store a reading, you must turn the memory on. Memory On or Memory Off is  indicated at the bottom of the Measuring screen (see Fig 4). ...
  • Page 19 February 2015  RT‐1 User Manual Ver 1.2  2. Select the “Memory” menu item and then press  .  3. Select the “Log Record” menu item and then press   to toggle ON (or OFF).  4. Go to the Measuring screen. When the memory is ON the bottom of the screen will  show ‘Next Memory’ followed by the memory log number (Mxx‐xx) and record number  (Mxx‐xx). When the memory is OFF, the screen will show “Memory Off”.    Change the memory group*:  * Memory group refers to a specific subset of record numbers within the RT‐1 memory bank  where readings can be stored. There are 99 memory logs, named M01 to M99.  Each memory  group can hold up to 99 readings.  1. Go to the Main Menu.  2. Select the “Memory” menu item and press  .  3. Select the “Change Log” menu item and press   .  4. Select the new group and press   .  5. The memory group has now been updated.    Note 1: An * symbol next to a group indicates that there are readings stored in that group. You  can continue to save readings to any group until the group is full (99 readings). (Firmware  version 1.6H).  Note 2: In future versions of the firmware, the device will flash a warning notice once the  memory group is full and it will automatically jump to the next empty group.    Take and store a reading  1. Place and hold the sensor end of the RT‐1 against the sample.  2.
  • Page 20 February 2015  RT‐1 User Manual Ver 1.2  To view a reading / log of readings:  1. Go to the Main Menu.  2. Select the “Memory” menu item and press  .  3. Select the “View Log” menu item and press  .  4. Select the group of interest and press   .  5. Using the arrow keys   and  , scroll up and down to view readings within the group.  6. To Flag a reading:  a. Highlight the reading of interest  b. Press   to view the Flag options  c. Scroll up and down using the arrow keys   and      d. Press   to select a Flag  e. The selected Flag will appear next to the “Flag:” text in the middle of the display  screen if the Flag has been successfully stored  7. To exit, press  .  Important Note: Once a reading has been flagged, the Flag cannot be removed or changed    To erase / clear a log: ...
  • Page 21 February 2015  RT‐1 User Manual Ver 1.2  6. If you are sure you wish to erase the entire group, select “Yes” and press  .  7. The group has now been erased.    Connecting the RT‐1 to the PC (via Bluetooth):    Windows XP and Windows 7  Please see supplementary notes for more information on the RT‐1 PC connection instructions  provided on the USB key in your RT‐1 box.   Document name: RT‐1_BT_PC_Connection Instructions.pdf    Installing the Bluetooth Software Dongle Provided  If your computer has no built‐in Bluetooth software, please take the following steps before  attempting to connect to the RT‐1:  • Insert Bluetooth USB Dongle provided with the RT‐1  • Allow PC time to connect to internet and download Bluetooth drivers    IMPORTANT: The CD provided with the Bluetooth Dongle is not necessary in cases where  Windows successfully finds the correct device drivers and recognises the Bluetooth Dongle (be  aware this can take upwards of 5‐10 mins depending on internet connection and operating  system). If after inserting the dongle you have waited an appropriate amount of time (10mins)  and Windows has not found the correct drivers and recognised your dongle then the provided  CD can be installed. Follow the instructions provided with the CD.  Note: you will need to connect the external Bluetooth USB dongle to the computer each time  you wish to connect to the RT‐1 to download data  RT‐1 Passkey for Bluetooth: 1  RT‐1 device name/ID name: RT1_SNXXXX (XXXX denotes the unit serial number)    Pairing and Connecting the Device with Bluetooth for the first time  1. Make sure Bluetooth is turned on and working on your computer  CoRMaGeo Instruments  RT‐1 Manual  Page 18 ...
  • Page 22 February 2015  RT‐1 User Manual Ver 1.2  2. Turn on the RT‐1 unit  3. Bluetooth Icon should appear in systems tray (If Bluetooth icon is not in the system tray,  go to the start menu, open the control panel, open “devices and printers” and click “add  device”)  4. Go through the “Add Bluetooth Device Wizard” to add a new device.   5. RT‐1 should appear as “RT1_xxxxxxx”, click on this and press next (XXXX denotes the RT‐ 1 serial number)  6. You will be prompted for a passcode, enter the passcode 1 and press next  7. Your device should now be successfully paired with computer  8. On the RT‐1, a Bluetooth symbol will appear on the screen when connected     Reconnecting the Device with Bluetooth (2 methods)  Method 1  1. Click Bluetooth icon in system tray and click “show Bluetooth devices”, you should see a  device named “RT1_xxxxxxx”, (or if Bluetooth icon is not in the system tray, go to the  start menu, open the control panel and find device named “RT1_xxxxxxx”)  2. Right click on “RT1_xxxxxxx” and select “remove device”  3. Click yes when prompted  4. Follow steps for connecting for the first time  Method 2  1. Click Bluetooth icon in system tray and click “show Bluetooth devices”, you should see a  device named “RT1_xxxxxxx”, (or if Bluetooth icon is not in the system tray, go to the  start menu, open the control panel and find device named “RT1_xxxxxxx”)  2. Right click on “RT1_xxxxxxx” and select “properties”  3. Select “services”  4.
  • Page 23 February 2015  RT‐1 User Manual Ver 1.2    To download data to the PC (via Bluetooth): Dumping the Data  Once the RT‐1 and the computer are paired and connected, you can dump the data to the  computer. No specialist software is required when dumping the data.    !IMPORTANT!   Before starting the dumping process, make sure that no other processes or applications are  running on you computer. If another application (e.g. backup program or anti‐virus software)  starts running during the dumping process, the data stream will be disrupted and the data  corrupted.     On the computer:  1. Open Microsoft Excel (downloading data will work in other programs that will accept a  text string e.g. Word or Notepad however Excel is what we recommend)  2. Open a new blank document  3. Click in an empty cell, let go of mouse and do not move mouse or press keys on  computer until data download is finished  On the RT‐1:  1. Go to Main Menu > Memory  2. Select “Send to PC” menu item and then press  .  3. The dumping process will now start and the data will start populating the excel  spreadsheet (do not touch the computer during this)  4. Save excel document  5. Once dumping is complete the RT‐1 will prompt you “Do you wish to erase the entire  memory”.  6. BEFORE selecting YES, check to make sure all the data was successfully transferred to  the Excel document and the document has been saved.  7. By scrolling, select YES or NO and press  . ...
  • Page 24 February 2015  RT‐1 User Manual Ver 1.2  9. Data download complete    Mac OS X  Please see supplementary notes for the RT‐1 Mac OSX connection instructions provided on the  USB key in your RT‐1 box.   Document name: RT‐1_BT_Mac_OS_X_Connection Instructions.pdf    Important Notes when dumping data:  • To abort the data dumping process press  .  • When dumping the data, the entire memory will be dumped each time.  • If the entire memory is empty and you select “Dump to PC” then an empty record will  dump to excel spreadsheet.  • The download process will abort if the Bluetooth connection is lost  • If the RT‐1 is turned off, the Bluetooth connection will be lost  CoRMaGeo Instruments  RT‐1 Manual  Page 21 ...
  • Page 25: Menu Items

    February 2015  RT‐1 User Manual Ver 1.2  7.  MENU ITEMS  The RT‐1 has four (4) Menu Screens:  1. MAIN   2. MEMORY   3. SETTINGS   4. SPECIAL       Figure 7 An overview of the menu structure for the RT‐1 CoRMaGeo Instruments  RT‐1 Manual  Page 22 ...
  • Page 26 February 2015  RT‐1 User Manual Ver 1.2    1. MAIN MENU     To go to the Main Menu, press   OR either of the arrow keys   and   from the  Measuring screen or   from any of the other Menus. Scroll down through the menu items,  press   and    scroll keys. To execute a menu item, press   when the desired menu item  is highlighted.      Figure 8 Main Menu screen      CoRMaGeo Instruments  RT‐1 Manual  Page 23 ...
  • Page 27 February 2015  RT‐1 User Manual Ver 1.2    2. SETTINGS MENU   To change any Settings Menu values, use the arrow keys,   and  , to scroll to the setting  you wish to change and press   to toggle through the various options. Once an option has  been selected using the   key, it is saved and activated immediately. To exit the Settings  Menu, press      I. Mode  VI. Beep  Switch between continuous SCAN and STEP  Switch the audio tone ON or OFF (only  modes of display operation.  operates when meter is in SCAN mode)  II. Units  Switch between SI and CGI units  The units are related as follows: k [SI] = 4 π  k [CGS].  III. Power Off  To conserve power, the unit will power off  after 5 minutes. This can be changed to  either 5min, 10min, 30min or NEVER.  IV. Backlight  To conserve power, the backlight will dim  after 1 minute. This can be changed to  either 1min, 5min or OFF (always dims).  V. Contrast  This can be changed between values 1‐6 to ...
  • Page 28 February 2015  RT‐1 User Manual Ver 1.2  3. MEMORY MENU     To view or change options within the Memory Menu press  , use the arrow keys,   and  , to scroll to the option you wish to view or change and press   to select the item or to  change the various values. To exit the Memory Menu, press  .    The RT‐1 unit is able to store over 9800 readings. Each individual reading is stored to a specific  memory log. The RT‐1 has 99 separate memory logs (M01‐M99), with the capacity of 99 stored  readings per log.     Log Record    Switch between memory ON or OFF.  Change Log  Change the memory group where the next  reading(s) are to be stored.  III. View Log  View each memory group and the readings  within each group. When viewing an  individual reading, it is possible to flag that  readings with a selection of 4 symbols.  Erase Log   Erase an entire log of readings. Note that it  is not possible to erase individual readings  directly from the unit.    Send to PC  Figure 10 Memory menu screen.  Send data to the PC    CoRMaGeo Instruments  RT‐1 Manual  Page 24 ...
  • Page 29 February 2015  RT‐1 User Manual Ver 1.2    Figure 11 Three (3) sub‐menus within the Memory menu.   Note: The * symbol indicates readings have been stored within that memory group.  CoRMaGeo Instruments  RT‐1 Manual  Page 25 ...
  • Page 30 February 2015  RT‐1 User Manual Ver 1.2  4. SPECIAL MENU     To view information within the Special Menu (Contact / Serial No. / Version / Language), use  the arrow keys,   and  , to scroll to the information you wish to view and press   to  select the item.   To change the Language settings within the Special Menu, use the arrow keys,   and  , to  highlight the Language option and keep pressing   to move through the various languages.   To exit the Special Menu, press  .    I. Contact  Displays the contact information for the  manufacturer (CoRMaGeo Instruments).  II. Serial No.  Displays the serial number details for the  instrument.  III. Version  Displays the software version installed on  the instrument.  IV. Language  Displays the language setting for the  instrument and allows the user to change  the language setting. English, Spanish,    Figure 12 Special Menu screen.  French and Italian are offered.     ...
  • Page 31: Bluetooth Interface

    February 2015  RT‐1 User Manual Ver 1.2    8.  BLUETOOTH INTERFACE  The RT‐1 can communicate to a PC via an inbuilt Bluetooth interface. Once the RT‐1 and the  computer is paired and connected, you can dump the data to the computer.    Before starting the dumping process, make sure that no other processes or applications are  running on you computer. If another application (e.g. backup program or anti‐virus software)  starts running during the dumping process, the data stream will be disrupted and the data  corrupted.     It is important to note that when dumping the data, the entire memory will be dumped each  time and the download process will abort if the Bluetooth connection is lost    Built‐in Bluetooth  If you are using a computer with built‐in Bluetooth the process for pairing the RT‐1 will differ  than the steps described on p.18. Please refer to instruction from the manual of your computer  or operating system.  CoRMaGeo Instruments  RT‐1 Manual  Page 27 ...
  • Page 32: Troubleshooting

    February 2015  RT‐1 User Manual Ver 1.2  .  TROUBLESHOOTING   The  RT‐1  is  a  sophisticated  measuring  instrument.  Any  unauthorized  modifications  or  adjustments to the RT‐1 electronics will void the Warranty.    If any operation described in this manual does not work, check the following:  1.  Check that the battery has sufficient power and replace if in doubt.  2.  Check the battery contacts and clean contacts if necessary.  3.  Check  alignment  and  fit  of  the  removable  sensor  head  into  the  meter.    It  should  slide  smoothly into the meter.   ...
  • Page 33: Calibration Frequency

    February 2015  RT‐1 User Manual Ver 1.2  .  CALIBRATION FREQUENCY   How often should the RT‐1 be calibrated?    RT‐1 users frequently ask how often factory calibration of the unit is required.    There is no single correct answer to this question. Calibration always represents an  instantaneous snapshot of conditions which is dependent upon a variety of factors, for  instance:     • Level of stress to which the equipment is subjected  • Stability of past calibrations  • Required measuring accuracy  • Quality assurance requirements     This means that the period of time between any two calibrations must be determined and  monitored by the user. To help you check and monitor your RT‐1 calibration, a Magnetic  Susceptibility Test Pad is provided on the base of RT‐1 case. To use, simply place your RT‐1 on  the “TEST HERE” sticker and take a reading. Values should fall within the range specified on the  calibration sheet. This range is also posted under the foam insert inside the lid.   We recommend a factory calibration interval of 1 to 2 years. In order to assist our customers,  CoRMaGeo Instruments offers the first calibration service for your RT‐1 free (ex freight). Simply  send your RT‐1 unit back to us and we will check and recalibrate the unit and issue a current RT‐ 1 Calibration Sheet.   Please contact us with any further questions about this service.    CoRMaGeo Instruments  RT‐1 Manual  Page 29 ...
  • Page 34: Specifications

    February 2015  RT‐1 User Manual Ver 1.2  .  SPECIFICATIONS  Standard System (What’s in the Box)  The RT‐1 standard system is supplied with:  RT‐1 Console with removable sensor unit  1GB USB with Operating Software, Operations Manual & Quick Start Guide  Bluetooth USB & Software  Three Alkaline AA Batteries & Mini‐Philips Screwdriver  Wrist Strap & Lanyard  1‐year Warranty  Calibration Certificate  Magnetic Susceptibility Test Pad  Sturdy Pelican® Case with foam insert  Protective silicon gummy    Technical Specifications  –5 Sensitivity (SI)   1 x 10   –5  Operating Range  1 x 10 to 1.0 SI  Units  SI or CGS  Operating Frequency  750Hz  Response Time  Less than 1 second  Operating Mode  Single or Continuous readings  Memory   More than 9800 readings and flags  Display Type & Rate  Liquid Crystal Display, with backlight  55 mm x 28 mm  Displays analog and digital readings and menus  Audio Output  Audio output on key touch ...