In this guide Features ..................1 Requirements ................1 In the box ..................2 Safety precautions ..............3 Front panel .................. 4 Rear panel ................... 4 Example of hardware configuration ........5 External controls ................ 5 The 1T-CL-SW software ............. 5 The web interface ...............
Page 4
Commands for controlling tvONE™ devices ....21 Scheduling macros ..............23 Creating and editing repeating schedules ....23 Creating and editing one-off events ......24 Adding and editing devices ............. 24 What are devices? ............24 Adding a device ..............25 Editing a device ..............
Thanks for buying this 1T-CL-322 Control Panel from tvONE™. The Control Panel allows you to control a range of devices through an Ethernet connection and relay outputs. It has red and blue LED backlights that you can use to create color themes and show activation of commands.
US model Wall-mounted keypad 1T-CL-322 1T-CL- USB Type A to Mini USB OTG adaptor with cable 3.5 mm Phoenix connectors 5 V / 2.6 A DC power adaptor, with regional connectors Pre-printed labels for buttons, with regional differences User guide tvONE...
Safety precautions Read all instructions before attempting to unpack, install or operate this equipment, and before connecting the power supply. Risk of injury from fire or electric shock Follow basic safety precautions. • Do not expose this product to rain or moisture. •...
48 V Power over Ethernet (PoE). Power/DC 5V If you don’t use PoE, connect the 5 V power adaptor. Relay/Relay out Connect to a device that requires 0-24 V / 8 A DC power through a relay or contact closure switch. tvONE...
Download the software for both the EU and US models from the Downloads tab at www.tvONE™.com/wall-plate-control-panel. The web interface You can control and configure the Control Panel from any modern browser with the web interface. The default port for the web interface is 80.
Page 10
Opening the web interface 1. To open the web interface, open any browser and enter the IP address for the Control Panel, or select the Web GUI link on the InfoFrom window. 2. Log in with username: admin and password: adminpw. tvONE...
Network settings You can adjust your network settings on the InfoFrom window of the1T-CL-SW software, and from the Network Settings tab of the web interface. Configuring your network address On the InfoFrom window, you can enable and disable DHCP and change your IP address, Subnet Mask, Gateway IP and DNS.
4. For a list of available commands, enter help. Note: follow each command with a carriage return. Commands are not case-sensitive. If you change the IP address of the Control Panel, the IP address for Telnet access changes as well. tvONE...
Page 13
Commands for external control Use these commands with an external Telnet or UDP control device. You can also use any of the commands for controlling Control Panels, relays, and other devices on pages 18 to 21. Command Parameter Description Use this command to IPCONFIG display the current IP configuration.
Page 14
Parameter Description Use this command to REBOOT reboot the system. Use this command to HELP (?) show the full list of commands. HELP N N = COMMAND Use this command to NAME show the description of a specific command. tvONE...
Configuring the Control Panel Configure what the buttons of the Control Panel do with the web interface. When you configure buttons, you associate one or two macros with each button. Each macro is a sequence of individual commands that you enter on the Command Settings tab.
The Control Panel comes with 6 primary macros installed for demonstrating and testing the Control Panel’s functionality. Each macro demonstrates different functions and turns on and off the LEDs and relays. See the default macros on the Macro Settings tab. tvONE...
Button Macro name Function LED RED 100% Turns on the red LEDs sequentially from 1 to 15/16 LED BLUE 100% Turns on the blue LEDs sequentially from 1 to 15/16 RED LIGHT OFF Switches off all the red LEDs BLUE LIGHT OFF Switches off all the blue LEDs LED DEMO Toggle the demo mode on or off...
Page 18
• list of devices. Enter the IP address and port number of the device. Most tvONE™ devices use port 10001. Relay switches on and off equipment connected to a relay •...
Page 19
6. Repeat steps 3-5 to add more commands, then save your changes. You can edit your macro to change, remove and reorder command strings. 7. Optional: choose a button mode on the Key Settings tab. Note: do not apply toggle mode and repeat mode to the same button.
Remove the protective film from the labels, then stick a label to the • button. Replacement labels You can buy extra blank labels, contact your tvONE™ sales representative. For contact details, see the back page of this guide. Part numbers: EU model: BLS-1T-CL-322-EU •...
Creating and editing command strings The Control Panel can store up to 128 command strings that are up to 128 characters long. You can store longer strings, but you can’t save as many of them. You create and edit command strings on the Command Settings tab.
LED of a specific button. N1 = % (0-100) N = BUTTON Use this command to change LEDRED N N1 (1-15/16) the state of the red LED of a specific button. N1 = % (0-100) tvONE...
Page 23
Command Parameter Description N1 = % Use this command to change LEDBLUES N (0-100) the state of all blue LEDs. N1 = % Use this command to change LEDREDS N (0-100) the state of all red LEDs. LEDSHOW N N = ON/OFF/ Use this command to change TOGGLE the state of all LEDs for a...
Controlling other devices You can control any device that can be controlled by Telnet commands, including tvONE™ devices, other Control Panels and the relay ports of other Control Panels. Choose targets for your commands when you create macros.
Commands for controlling tvONE™ devices For a list of the commands you can use with a specific tvONE™ device, see the API document which appears on the Support Information tab for that product at tvONE™.com. Examples of command strings for controlling tvONE™ devices Here is an example of how to create command strings to control equipment through the Ethernet port.
Page 26
To load preset 1: preset.take=1 • To log out: logout • To load preset 1: Command Name: C3-510 Preset 1 • Interface: TELNET • Param 1: IP address of the C3-510 • Param 2: Port number of the C3-510 • Command: • login(admin,adminpw)\x0dpreset.take=1\x0dlogout\x0d\ tvONE...
Scheduling macros You can create one-off events and repeating schedules to trigger a macro automatically. Repeating schedules can only trigger the macro once per day, but you can set up multiple repeating schedules to trigger the same macro at different times.
IP address and port number of each device. Add and edit devices on the Device Settings tab. What are devices? Devices are any equipment that can be controlled by Telnet commands, including tvONE™ devices. You can also add other Control Panels to your list of devices. tvONE...
1. Select an empty row and then select the Edit button. 2. Enter a name, the IP address, and the port of the device. tvONE™ products use the default port 10001. Editing a device To change an existing device, select the device and then select the •...
You can choose a new username and password on the System Settings tab. Setting a timeout time The web interface automatically logs you out after a period of inactivity. Choose a time between 5 and 60 minutes on the System Settings tab. tvONE...
Saving and restoring your settings You can create multiple backup copies of your settings and save them to your computer. If something goes wrong, you can restore your backed up settings. Save and restore settings on the System Settings tab. When you restore settings, refresh your web browser.
Rebooting the Control Panel You can reboot the Control Panel from the System Settings tab or from InfoFrom window of the 1T-CL-SW software. Firmware Finding your firmware version Find your firmware version on the InfoFrom window of the 1T-CL-SW software. tvONE...
Updating firmware Update the control panel by connecting it to your computer. 1. Download the latest firmware from www.tvONE™.com/firmware- updates. Search for 1T-CL-322. 2. Extract any zipped files and copy the .BIN file to your computer. 3. Remove the front plate of the Control Panel.
Page 34
When the transfer is complete, all LEDs on the Control Panel light The update is complete when the Control Panel reboots automatically. You might need to refresh the web interface as part of the firmware upgrade process. Press F5 to refresh your browser, or reconnect with the 1T-CL-SW software. tvONE...
Specifications Input ports EU model: 15 buttons, 1 IP (RJ45) • US model: 16 buttons, 1 IP (RJ45) • Output ports EU model: 2 relay • US model: 1 relay • Ethernet protocol TCP/IP • Power supply 5 V/2.6 A DC (US/EU standards, •...
Need help?
Do you have a question about the 1T-CL-322-EU and is the answer not in the manual?
Questions and answers