Content 1. Specification ..................................................................2.Self- check and fault diagnoses 3. Error codes and solutions .................................. 4.The instruction of the main parts .................................. introduction 5.The introduction of the display and keys .................................. 6. The introduction of the parameter setting .................................. 7.
2.Self- check and fault diagnoses 1. Specification Rated voltage When turn on the machine, it will start self-check by itself. This function can check whether all the sensors and AC220V±10% 50Hz±5% AC220V±10% 50Hz±5% /Frequency relative circuit are in good working condition or not. When detecting a fault, the fault code will be showed in the Power 110W(Max) counting display:...
There is something covered with the start Remove the suspicious note from the stacker; Start Sensor Fault Clean the start sensor Double note detected by the IR detection sensor press “RESET”to continue; UV Sensor Fault Problem with the UV sensor Replace the UV sensor IR sensitivity level is too high Decrease the IR sensitivity level...
4.The instruction of the main parts introduction 5.The introduction of the display and keys 5.1 The diagram of the main display and the keys 1.counting 1.start sensor guide 2.banknote 2.handle feeding wheel 3.main display 3.UV light assembly assembly 4.banknote 4.side display transporting wheel 5.banknote...
Page 6
5.3 The introduction of the side display panel and the key function Press this key to switch the AUTO/MUL counting mode. Function Side display Press this key to turn on/off the UV detection. 1.Press this key can clear all the fault message, then keeping counting.
6. The introduction of the parameter setting 6.1 Sensitivity level setting 6.1.7 Break Time: the time to stop counting. The range is 10-100ms; the default is 33ms. When the display shows some error codes during the counting, the user can adjust the according sensitivity level 6.1.8 Start Val: start sensor sensitivity value, ranging from 0 to 9(“0”...
7. Restore to the factory setting 6.1.17 UV Val: UV detection sensitivity value, ranging from 0 to 10 (“0”is off, “10” is the highest); the default is Press “UV+MG+RESET”at the same time, meanwhile turning on the machine, after hearing “beep”sound, the “4”.
9. Precaution for handling the machine 10. Cautions Damp and/or badly stained notes should be Please read all the instructions as below before using the machine, or it will lead to some danger and fault avoided; ——Avoid exposing the product to the sunlight. ——The product should have well earthing performance ...
11. Maintenance The counting sensor and the feeding sensor are belong to the optical equipment. If there is some dust and dirty things covering the sensor, it will lead to the fault when the machine is working . The user should clean the machine after using.