Modbus - BEL LDD240-WU User Manual

240 w universal dc-dc converter
Hide thumbs Also See for LDD240-WU:
Table of Contents

Advertisement

LDD240-WU
240 W Universal DC-DC Converter

4.7 MODBUS

LDD240-WU communicates through Modbus/RTU as specified on "MODBUS over Serial Line" and "MODBUS APPLICATION PROTOCOL
SPECIFICATION" documents available on http://www.modbus.org/.
Table 1 contains the field types and Table 2 the mapped fields.
TYPE
MODBUS FUNCTION CODES
READ
BIT
1, 2
SINT16
3, 4
UINT16
3, 4
ADDRESS
TYPE
SETTINGS
0x1000
UINT16
0x1010
UINT16
0x1011
UINT16
0x1012
UINT16
0x1013
UINT16
0x1014
UINT16
METERING
0x2000
SINT16
0x2001
SINT16
0x2002
SINT16
0x2003
SINT16
STATE
0x4000
BIT
0x4001
BIT
0x4002
BIT
0x4003
BIT
0x4004
BIT
0x4005
BIT
0x4006
BIT
0x4007
BIT
DESCRIPTION
WRITE
5, 15
Single bit with value 0 or 1
6, 16
Signed 16 bit value (2's complement)
6, 16
Signed 16 bit value (2's complement)
Table 1. Modbus types
R/W
UNIT
MIN.
R/W
1
1
R/W
0.01
4.5
R/W
0.1
1
R/W
1
1
R/W
1
1
R/W
1
0
R
0.1V
0
R
0.1V
0
R
0.1V
0
R
0.1V
0
R
1
0
R
1
0
R
1
0
R
1
0
R
1
0
R
1
0
R
1
0
R
1
0
Table 2. Modbus fields
MAX.
DESCRIPTION
99
Modbus address.
57
Nominal output voltage [V].
11
Maximal output current [A].
2
Operating mode (§3.1):
1. Single
2. Parallel
2
Current limitation (§3.2):
1. Hiccup
Constant current
1
Output enable.
0: Disabled
1: Enabled
60
Output voltage [V].
15
Output current [A].
360
Output power [W].
60
Input voltage [V].
1
DC OK
1
Output disabled.
1
Output short circuit.
1
Output overload.
1
USB powered.
1
Over temperature warning.
1
Over temperature error.
1
Output over voltage error.
Asia-Pacific
Europe, Middle East
+86 755 298 85888
© 2017 Bel Power Solutions & Protection
North America
+353 61 225 977
+1 408 785 5200
BCG.00966_AA
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents