Sirona SIROSONI L Operating Instructions Manual

Sirona SIROSONI L Operating Instructions Manual

Periosonic

Advertisement

6278415.book Seite 1 Montag, 17. Oktober 2016 11:28 11
pfolplkf`LiLqi=
mÉêáçpçåáÅ
Instructions for use
båÖäáëÜ
léÉê~íáåÖ=fåëíêìÅíáçå

Advertisement

Table of Contents
loading

Summary of Contents for Sirona SIROSONI L

  • Page 1 6278415.book Seite 1 Montag, 17. Oktober 2016 11:28 11 pfolplkf`LiLqi= mÉêáçpçåáÅ Instructions for use båÖäáëÜ léÉê~íáåÖ=fåëíêìÅíáçå...
  • Page 2: Table Of Contents

    Table of Contents Operating Instruction SIROSONIC/L/TL, PerioSonic Table of Contents Before you begin … ..................Structure of the document ..................... Service life of Sirona instruments.................. Safety information ................... Technical description ..................Task..........................Calculus detection - functioning ..................Ultrasonic handpiece design ..................
  • Page 3 6278415.book Seite 3 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic Table of Contents Initial start-up and longer breaks in use ................ Prior to starting the work day..................Before each patient ....................... Operation ......................Connecting the ultrasonic handpiece to the supply hose ..........Detaching the ultrasonic handpiece from the supply hose..........
  • Page 4 6278415.book Seite 4 Montag, 17. Oktober 2016 11:28 11 Table of Contents Operating Instruction SIROSONIC/L/TL, PerioSonic Conditioning ....................Conduct pre-disinfection....................Automated cleaning and disinfecting ................Manual cleaning and disinfection .................. Sterilizing........................Maintenance ....................Maintaining the water channel..................Cleaning the light guide surfaces .................. Replacing the spray water cartridge................
  • Page 5 6278415.book Seite 5 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic Table of Contents Spare parts and consumables ................ Storage and transport conditions ..............Disposal ......................62 78 415 D3275.201.04.09.02...
  • Page 6: Before You Begin

    6278415.book Seite 6 Montag, 17. Oktober 2016 11:28 11 1 Before you begin … Operating Instruction SIROSONIC/L/TL, PerioSonic Before you begin … SIROSONIC/L/TL / PerioSonic complies with state-of-the-art technical Complies with state-of-the-art technology without general standards regulations. 1. Read the operating instructions prior to using SIROSONIC/L/TL / Read/observe _ general PerioSonic.
  • Page 7 6278415.book Seite 7 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 1 Before you begin … ● Cleaning and biofilm management of implants as well as metallic and ceramic restorations (implant cleaning tip) ● Irrigation of treated root channels (endo), ●...
  • Page 8: Structure Of The Document

    6278415.book Seite 8 Montag, 17. Oktober 2016 11:28 11 1 Before you begin … Operating Instruction SIROSONIC/L/TL, PerioSonic Structure of the document 1.1.1 Labeling of information Warnings ➢ To prevent injuries, please observe all warnings. Warnings are labeled as follows: DANGER! indicates a danger leading to death or serious injury if not avoided.
  • Page 9 6278415.book Seite 9 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 1 Before you begin … 1.1.2 Formats and symbols The formats and symbols used in this document have the following meaning: ✔ Prerequisite Requests you to do something. 1.
  • Page 10: Service Life Of Sirona Instruments

    Service life of Sirona instruments When used as intended: Service life 5 + 3 years /3 + 1 1/2 years ● Non-moving parts of Sirona instruments have a typical service life of Standard_Sirona approx. 5 years ● Moving parts of Sirona instruments have a typical service life of approx.
  • Page 11 6278415.book Seite 11 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 1 Before you begin … 1.2.1 Service time for the tips and torque wrench After 12 months of service time, the tips and included torque wrench have reached their wear limit and must be disposed of. Exception: SIROIMPLANT IP1 reaches its service time after 1,000 treatments or 24 months.
  • Page 12: Safety Information

    ● Comply with the Intended use of the equipment. ● You should always keep these operating instructions within reach for further reference. ● Use SIROSONIC/L/TL / PerioSonic only with Sirona equipment. Scaler only with Sirona ● Only use the torque wrench included with each tip.
  • Page 13 Do not repair the ultrasonic handpieces and tips on your own. Repair _ Scaler Spare and accessory parts Use only original Sirona parts or parts approved by Sirona. Safe Accessory parts operation is not guaranteed for parts that have not been approved by Sirona.
  • Page 14 6278415.book Seite 14 Montag, 17. Oktober 2016 11:28 11 2 Safety information Operating Instruction SIROSONIC/L/TL, PerioSonic Cardiac pacemakers and implanted defibrillators Sirona does not recommend using ultrasonic scalers for patients and Pacemakers and defibrillators equipment users with cardiac pacemakers and/or implanted defibrillators.
  • Page 15: Technical Description

    Calculus can be detected only with the SIROPERIO 4 PS ultrasonic tip PerioScan in combination with the PerioSonic handpiece on the Sirona PerioScan. Detection: The physical vibration patterns of the ultrasonic tip are analyzed and the contacted tooth surface is thus detected. The substance or material of the tooth being examined, not the surface structure, is detected here.
  • Page 16: Ultrasonic Handpiece Design

    6278415.book Seite 16 Montag, 17. Oktober 2016 11:28 11 3 Technical description Operating Instruction SIROSONIC/L/TL, PerioSonic When the software detects root surfaces the signal green lights up green - if calculus is detected, the signal ring lights up blue. Observe the notes in the operating instructions for PerioScan.
  • Page 17 6278415.book Seite 17 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 3 Technical description PerioSonic design PerioSonic Tip mount Light aperture Signal ring Control ring Hose nut 62 78 415 D3275.201.04.09.02...
  • Page 18: Technical Data

    6278415.book Seite 18 Montag, 17. Oktober 2016 11:28 11 3 Technical description Operating Instruction SIROSONIC/L/TL, PerioSonic Technical data Ultrasonic handpiece Scaler SIROSONIC SIROSONIC L SIROSONIC TL PerioSonic Oscillation frequency in kHz 25 - 32 25 - 32 25 - 32 25 - 32 Spray function Spray water regulation at the coupling...
  • Page 19 6278415.book Seite 19 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 3 Technical description Treatment center SIROSONIC SIROSONIC TL SIROSONIC L Lamp voltage in V, at the lamp 3.6 ±0.1 Lamp current in A Halogen lamp 0.03 0.03 Spray water flow in ml/min (with fully-opened water regulator) Spray water pressure in bar (without tip) 2 ±0.2...
  • Page 20 6278415.book Seite 20 Montag, 17. Oktober 2016 11:28 11 3 Technical description Operating Instruction SIROSONIC/L/TL, PerioSonic Depending on the treatment center and its accessories PerioScan PerioSonic Lamp voltage in V, at the lamp Lamp current in A Halogen lamp 0.03 Spray water flow in ml/min (with fully-opened water regulator) 62 78 415 D3275.201.04.09.02...
  • Page 21 6278415.book Seite 21 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 3 Technical description PerioSonic Spray water pressure in bar (without tip) 1-1.5 Recommended water content in spray in ml/min > 30 ml/min Operating conditions Ambient temperature 10°C - 40°C (50°F - 104°F) Relative humidity 30% - 95% Air pressure...
  • Page 22: Power Settings For Ultrasonic Tips

    6278415.book Seite 22 Montag, 17. Oktober 2016 11:28 11 3 Technical description Operating Instruction SIROSONIC/L/TL, PerioSonic This product bears the CE mark in accordance with the provisions of the CE mark Council Directive 93/42/EEC of June 14, 1993 concerning medical devices (MDD). 0123 Power settings for ultrasonic tips The tips can be used at the following maximum power:...
  • Page 23 6278415.book Seite 23 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 3 Technical description SIROSONIC SIROSONIC L SIROSONIC TL PerioSonic SIROPERIO PE 1 ≤ 70% ≤ 70% ≤ 70% ≤ 70% SIROPERIO PE 2 100% 100% 100% 100% SIROPERIO PE 3 100% 100% 100%...
  • Page 24 6278415.book Seite 24 Montag, 17. Oktober 2016 11:28 11 3 Technical description Operating Instruction SIROSONIC/L/TL, PerioSonic SIROSONIC SIROSONIC L SIROSONIC TL PerioSonic ≤ 70% ≤ 70% ≤ 70% ≤ 70% SIROIMPLANT IP 1 Endo tip no. 5 ≤ 4% ≤ 4% or Endo Endo function 1e - ≤...
  • Page 25: Preparation

    6278415.book Seite 25 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 4 Preparation Preparation Initial start-up and longer breaks in use ➢ An adequate normalization phase must be maintained following Scaler transport before initial operation. ➢ Sterilize the scaler and accessory parts prior to startup [ → 72]. ➢...
  • Page 26 6278415.book Seite 26 Montag, 17. Oktober 2016 11:28 11 4 Preparation Operating Instruction SIROSONIC/L/TL, PerioSonic 4. Check the ultrasonic tip for usability [ → 32]. 5. Set a sufficient amount of cooling water (> 30 ml/min) [ → 35]. 6. Use filtered water only (< 50 µm). 7.
  • Page 27: Operation

    6278415.book Seite 27 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Operation NOTICE! Tips wear out and can bend resulting in a performance loss Use only faultless tips and risk of breakage. Use only ultrasonic tips that are not worn or bent. Do not reshape bent tips.
  • Page 28: Connecting The Ultrasonic Handpiece To The Supply Hose

    6278415.book Seite 28 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Connecting the ultrasonic handpiece to the supply hose Connecting SIROSONIC/L Attaching SIROSONIC/L 1. Compare the hole pattern in the handpiece with the small tubes in the hose coupling. 2.
  • Page 29: Detaching The Ultrasonic Handpiece From The Supply Hose

    Connecting SIROSONIC TL and PerioSonic Attaching SIROSONIC TL and PerioScan 1. Align the Sirona logo with the recess on the hose coupling. 2. Hold the hose nut (A) firmly and insert the ultrasonic handpiece until it clicks audibly into place.
  • Page 30 6278415.book Seite 30 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Detaching SIROSONIC/L Detaching SIROSONIC/L ✔ The ultrasonic handpiece is not in operation. 1. Hold the supply hose by the control ring (B) and not by the hose nut (A)! 2.
  • Page 31: Inserting And Removing The Ultrasonic Tip

    6278415.book Seite 31 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Inserting and removing the ultrasonic tip Inserting the ultrasonic tip ✔ The ultrasonic handpiece is not in operation. Insert using a torque wrench 1. Insert the ultrasonic tip into the torque wrench (A). 2.
  • Page 32: Checking The Ultrasonic Tip For Usability

    6278415.book Seite 32 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Checking the ultrasonic tip for usability ✔ The included checkcard for tips is available. 1. Place the ultrasonic tip against the tip gauge with the edge (A) of the wrench surface positioned as shown in the corresponding illustration.
  • Page 33: Adjusting The Power For The Ultrasonic Tips

    6278415.book Seite 33 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Adjusting the power for the ultrasonic tips CAUTION! Wear and bending of the tips lead to loss of performance and hazards. Tips may not be reshaped. There is a risk of breakage during operation and performance may be lost or reduced.
  • Page 34 6278415.book Seite 34 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic values do not coincide with the values 1 to 5 in ultrasonic operation (SIROSONIC TL with TENEO and SINIUS, SIROSONIC L with INTEGO). 62 78 415 D3275.201.04.09.02...
  • Page 35: Adjusting The Cooling Spray

    6278415.book Seite 35 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Adjusting the cooling spray ➢ Adjust the flow rate of the cooling water using the control ring (A) (> General adjustment > 30 ml/min 30 ml/min). Tip: You can measure the amount of cooling water with a measuring cup and watch.
  • Page 36 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic ... for SIROSONIC TL and PerioSonic: The Sirona logo is used as a marking for the SIROSONIC TL and PerioSonic. The minimum water flow is set when the control ring is turned in a General III clockwise direction until it reaches the stop.
  • Page 37: Treatment

    6278415.book Seite 37 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Treatment CAUTION! If the sealing ring of SIROSONIC TL or PerioSonic is defective, damaged or worn, this can lead to false detection results! Always check for proper fit and condition of the sealing ring before using the SIROSONIC TL and PerioSonic.
  • Page 38 6278415.book Seite 38 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic IMPORTANT: Change tips only when the device is switched off. [ → 31] The illustration to the left shows how the handpiece should be held during treatment. Always keep the instrument in motion, either up and down the tooth or across the proximal surface in lingual or buccal direction away from the tooth.
  • Page 39 6278415.book Seite 39 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation NOTICE! During treatment, do not allow the device to come into contact with metal/ceramic restoration (except when using a CEM tip). Prostheses may otherwise become loose due to the high-frequency ultrasonic vibrations.
  • Page 40 6278415.book Seite 40 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic 5.7.1 Using SIROPERIO tips For removing calculus in subgingival operation, even in deep gingival pockets. SIROPERIO tips provide you with optimal access to all regions, so that you can efficiently remove calculi while at the same time preserving healthy tooth substance.
  • Page 41 6278415.book Seite 41 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation SIROPERIO PE 1 - straight, narrow 62 78 415 D3275.201.04.09.02...
  • Page 42 6278415.book Seite 42 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic SIROPERIO PE 2 - right curved, for posterior teeth 62 78 415 D3275.201.04.09.02...
  • Page 43 6278415.book Seite 43 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation SIROPERIO PE 3 - left curved, for posterior teeth 62 78 415 D3275.201.04.09.02...
  • Page 44 6278415.book Seite 44 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic SIROPERIO 4 PS - straight, also especially for use with PerioScan for detection. 62 78 415 D3275.201.04.09.02...
  • Page 45 6278415.book Seite 45 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation SIROPERIO PE 5 - right curved, for posterior teeth 62 78 415 D3275.201.04.09.02...
  • Page 46 6278415.book Seite 46 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic SIROPERIO PE 6 - left curved, for posterior teeth 62 78 415 D3275.201.04.09.02...
  • Page 47 6278415.book Seite 47 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation 5.7.2 Using scaling tips Scaling tip no. 1L - for course cleaning, lingual, buccal IMPORTANT: Do not use proximally! 62 78 415 D3275.201.04.09.02...
  • Page 48 6278415.book Seite 48 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Scaling tip no. 2L - versatile for, lingual, buccal, proximal use 62 78 415 D3275.201.04.09.02...
  • Page 49 6278415.book Seite 49 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Scaling tip no. 3L - for universal use on either side Tip: The tip is especially suitable for removing supragingival plaque and for the interdental space. 62 78 415 D3275.201.04.09.02...
  • Page 50 6278415.book Seite 50 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Scaling tip no. 4L Tip: The tip is particularly suitable for supragingival and subgingival tooth surfaces, dental necks and for the interdental space. The rear molars are more accessible with this tip. 5.7.3 Using SIRORETRO tips SIRORETRO tips are intended to be used for retrograde root treatment...
  • Page 51 6278415.book Seite 51 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation ✔ Cooling water flow is cut off using control ring (A). 1. Detach the handpiece from the hose. 2. Insert the spray adapter (B) between the hose coupling and the handpiece.
  • Page 52 6278415.book Seite 52 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic SIRORETRO KR Short, angled to the right for treatment of the left lower jaw or right upper jaw. SIRORETRO GR Long, angled to the right for treatment of the left lower jaw or right upper jaw.
  • Page 53 6278415.book Seite 53 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation SIRORETRO KL Short, angled to the left for treatment of the right lower jaw or left upper jaw. SIRORETRO GL Long, angled to the left for treatment of the right lower jaw or left upper jaw.
  • Page 54 6278415.book Seite 54 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic 5.7.4 Using SIROPREP tips SIROPREP tips are equipped with grinding blocks to remove proximal caries in the distal and mesial areas. D1 – Small tip for removing distal caries D2 –...
  • Page 55 6278415.book Seite 55 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation 5.7.5 Using CEM set no. 6L The CEM tip is used to insert inlays (e.g. CEREC) using hardening composites with thixotropic properties. CAUTION! The CEM tip should be used only at max. 30% (PerioSonic) or max.
  • Page 56 6278415.book Seite 56 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Inserting the ultrasonic tip ✔ The ultrasonic handpiece is not in operation. 1. Rotate the ultrasonic tip slowly using the torque wrench (A) up to a quarter revolution past the resistance.
  • Page 57 6278415.book Seite 57 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation 1. Place the tip on the inlay without applying any pressure. 2. Switch the handpiece on for a few seconds to greatly reduce the viscosity of the hardening composite (thixotropy) and insert the inlay almost without using pressure.
  • Page 58 6278415.book Seite 58 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic 5.7.6 Using the endo tip no. 5 This ultrasonic tip is intended for flushing the prepared root canals (invasive procedure). Before treatment, the spray adapter must be inserted for supplying external irrigation fluids (e.g.
  • Page 59 6278415.book Seite 59 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation The endo tip no. 5 is used for flushing the prepared root canals. 1. Screw the ultrasonic tip in manually using the endo key (A). 2. Then remove the endo key. CAUTION! Screw and unscrew the endo tip no.
  • Page 60 6278415.book Seite 60 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Seating the root canal instrument 1. Insert the root canal instrument (A) into the chuck (B) up to the stop and tighten the knurled screw manually. 2.
  • Page 61 6278415.book Seite 61 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation Setting the depth stop 1. Sett depth stop (A), e.g. after an intraoral X-ray, by pulling out or pushing in the depth stop up to the required depth manually. 2.
  • Page 62 6278415.book Seite 62 Montag, 17. Oktober 2016 11:28 11 5 Operation Operating Instruction SIROSONIC/L/TL, PerioSonic Adjusting the rinsing medium 1. Set the NaCl pump. 2. Hold the ultrasonic handpiece with the instrument pointing up. 3. Adjust the flow of the rinsing medium so that it rises up to the tip of the instrument.
  • Page 63 6278415.book Seite 63 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 5 Operation 5.7.7 Using the SIROIMPLANT tip CAUTION! SIROIMPLANT IP 1 may only be used on SIROSON L, SIROSONIC/L/TL and PerioSonic. This tip is used for biofilm management and for cleaning implants as well as metallic and ceramic restorations.
  • Page 64: Follow-Up

    6278415.book Seite 64 Montag, 17. Oktober 2016 11:28 11 6 Follow-up Operating Instruction SIROSONIC/L/TL, PerioSonic Follow-up After each treatment session NOTICE! Condition immediately, or at the latest, one hour after Immediately after treatment treatment. CAUTION! You can puncture your hand with an ultrasonic Scaler Puncture wound _ Tip handpiece when the tip is inserted.
  • Page 65 6278415.book Seite 65 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 6 Follow-up 5. Transport the ultrasonic handpiece, ultrasonic tip and torque wrench to the hygiene room in a suitable transport container. 6. Conduct automatic conditioning [ → 67]. Manual conditioning [ → 70] is possible in exceptional cases if the national/local regulations are followed.
  • Page 66: Conditioning

    6278415.book Seite 66 Montag, 17. Oktober 2016 11:28 11 7 Conditioning Operating Instruction SIROSONIC/L/TL, PerioSonic Conditioning Conduct pre-disinfection NOTICE! Do not use any strong acidic or alkaline solutions (5 < pH < 9) No strong acidic, alkaline or chlorine solutions or solutions containing chlorine. ✔...
  • Page 67: Automated Cleaning And Disinfecting

    Automated cleaning and disinfecting ... 7.2.1 ... with a DAC UNIVERSAL We recommend using Sirona DAC UNIVERSAL (Flex lid) for Sirona - DAC Universal (Flex lid) automated cleaning and disinfection (inside and outside). For further details, refer to the operating instructions supplied with the unit.
  • Page 68 6278415.book Seite 68 Montag, 17. Oktober 2016 11:28 11 7 Conditioning Operating Instruction SIROSONIC/L/TL, PerioSonic 7.2.2 ... with cleaning and disinfection equipment NOTICE! Do not use any strong acidic or alkaline solutions (5 < pH < 9) No strong acidic, alkaline or chlorine solutions or solutions containing chlorine.
  • Page 69 6278415.book Seite 69 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 7 Conditioning 1. Check whether the instruments are clean after conditioning under good lighting (min. 500 lux) and color rendering index (min. 80 Ra). 2. If they are still dirty, repeat the process. For further processing, the instruments should be dry and free of residue.
  • Page 70: Manual Cleaning And Disinfection

    6278415.book Seite 70 Montag, 17. Oktober 2016 11:28 11 7 Conditioning Operating Instruction SIROSONIC/L/TL, PerioSonic Manual cleaning and disinfection IMPORTANT: Manual conditioning is possible in exceptional cases if Manual conditioning is possible in exceptional cases the national/regional regulations are followed. The national/regional regulations are to be checked before.
  • Page 71 6278415.book Seite 71 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 7 Conditioning 1. Brush the ultrasonic handpiece, detached tip and torque wrench under running water (< 38 °C, < 100 °F, at least drinking water quality) and good lighting (min. 500 lux) and color rendering index (min.
  • Page 72: Sterilizing

    6278415.book Seite 72 Montag, 17. Oktober 2016 11:28 11 7 Conditioning Operating Instruction SIROSONIC/L/TL, PerioSonic Sterilizing ✔ The instruments are cleaned and disinfected. Steps _ Scaler II 134°C 274°F ✔ If necessary, the ultrasonic handpiece and accessories can be sterilized in packaging suitable for sterilization and storage, e.g. paper/plastic composite packaging or container.
  • Page 73 6278415.book Seite 73 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 7 Conditioning Steam sterilizers that comply with the requirements of either EN 13060, DAC PROFESSIONAL _ Scaler class B (for example, DAC PREMIUM / DAC PROFESSIONAL) or EN 13060, class S and are also suitable for the sterilization of ultrasonic handpieces and ultrasonic tips are approved.
  • Page 74: Maintenance

    6278415.book Seite 74 Montag, 17. Oktober 2016 11:28 11 8 Maintenance Operating Instruction SIROSONIC/L/TL, PerioSonic Maintenance NOTICE! Never oil the ultrasonic handpiece! Never oil the scaler Maintaining the water channel CAUTION! Insufficient cooling leads to overheating of the Scaler without SiroAir L preparation site, the tip, and the handpiece.
  • Page 75: Cleaning The Light Guide Surfaces

    6278415.book Seite 75 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 8 Maintenance Cleaning the light guide surfaces 1. Unscrew the screw-on cap with the sealing ring or signal ring. Scaler 2. In order to avoid scratching the surfaces, blow off any dirt particles with air from a dry syringe.
  • Page 76: Replacing The Spray Water Cartridge

    8 Maintenance Operating Instruction SIROSONIC/L/TL, PerioSonic Replacing the spray water cartridge Required accessories ● Spray water cartridge ● Sirona T1 Spray T1 spray If the spray water cartridge leaks or is clogged..for SIROSONIC/L SIROSONIC/L 1. Detach the ultrasonic handpiece from the supply hose.
  • Page 77 6278415.book Seite 77 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 8 Maintenance ... for SIROSONIC TL or PerioSonic SIROSONIC TL / PerioSonic 1. Detach the ultrasonic handpiece from the supply hose. 2. Position the longest partial marking of the control ring (A) opposite the recess (B).
  • Page 78: Replacing The Halogen Lamp/Led

    6278415.book Seite 78 Montag, 17. Oktober 2016 11:28 11 8 Maintenance Operating Instruction SIROSONIC/L/TL, PerioSonic Replacing the halogen lamp/LED ...for SIROSONIC L SIROSONIC Heading CAUTION! The lamp can be hot. Risk of burns! Allow the lamp to cool Risk of burning from lamps down.
  • Page 79 6278415.book Seite 79 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 8 Maintenance 1. Detach the ultrasonic handpiece. 2. Detach the control ring (B). 3. Insert a probe into the hole behind the lamp socket and push the defective halogen/LED lamp (A) out of the socket. 4.
  • Page 80: Spare Parts And Consumables

    6278415.book Seite 80 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic Spare parts and consumables Basic version SCALER Basic version SIROSONIC/L Scaling tip no. 3L 18 94 455 Scaling tip no. 4L 18 94 463 SIROSONIC L handpiece 59 13 509 Torque wrench...
  • Page 81 6278415.book Seite 81 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables SIROSONIC TL Scaling tip no. 3L 18 94 455 Scaling tip no. 4L 18 94 463 SIROSONIC TL handpiece 62 12 216 Torque wrench 60 06 196 Cleaning wire 24 00 232...
  • Page 82 6278415.book Seite 82 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic PerioSonic Basic equipment when purchased individually PerioSonic handpiece 60 30 410 Cleaning wire 24 00 232 Tip gauge 54 55 667 Ultrasonic handpiece sets without tips SIROSONIC L (2 pcs.) 65 62 834 SIROSONIC TL (2 pcs.)
  • Page 83 6278415.book Seite 83 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables Special accessories Special accessories tips Scaling tips Tip no. 1L 89 24 250 Tip no. 2L 89 24 268 Tip no. 3L 18 94 455 Tip no.
  • Page 84 6278415.book Seite 84 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic Tip set no. 4L (6 pcs.) 65 41 051 Torque wrench 60 06 196 62 78 415 D3275.201.04.09.02...
  • Page 85 6278415.book Seite 85 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables SIROPERIO tips SIROPERIO PE 1 60 44 825 SIROPERIO PE 2 60 44 833 SIROPERIO PE 3 60 44 841 SIROPERIO 4 PS 61 77 005 SIROPERIO PE 5 63 43 078...
  • Page 86 6278415.book Seite 86 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic SIRORETRO tips SIRORETRO KL 54 57 887 SIRORETRO KR 54 57 895 SIRORETRO GL 54 57 903 SIRORETRO GR 54 57 911 Spray adapter L 60 02 286 PerioSonic spray adapter 61 41 852...
  • Page 87 6278415.book Seite 87 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables SIROPREP tips SIROPREP M1, small, mesial 59 04 276 SIROPREP M2, large, mesial 59 47 358 SIROPREP D1, small, distal 59 47 309 SIROPREP D2, large, distal 59 47 366 Torque wrench...
  • Page 88 6278415.book Seite 88 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic Endo tip no. 5 and accessories Item Designation Endo key, knurled bushing 18 95 080 PerioSonic spray adapter (for SIROSONIC TL 61 41 852 and PerioSonic) Spray adapter L (for SIROSON C8, SIROSON L, 60 02 286...
  • Page 89 6278415.book Seite 89 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables Item Designation Hose clamp for saline hose (recommended 89 28 392 quantity: 5) Slit hose piece for depth stop (recommended 18 94 786 quantity: 5) 62 78 415 D3275.201.04.09.02...
  • Page 90 6278415.book Seite 90 Montag, 17. Oktober 2016 11:28 11 9 Spare parts and consumables Operating Instruction SIROSONIC/L/TL, PerioSonic SIROIMPLANT tips SIROIMPLANT IP 1, incl. insert IP 1 (5 pcs.) 63 43 052 Insert IP 1, 5 pcs. 63 43 094 Knurled bushing, endo key 18 95 080 62 78 415 D3275.201.04.09.02...
  • Page 91 6278415.book Seite 91 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 9 Spare parts and consumables CEM set comprising: CEM set no. 6 L 18 94 307 CEM tip no. 6L Contact caps for inlays (2 pcs.) Torque wrench Contact cap (10 pcs.) 18 94 372 62 78 415 D3275.201.04.09.02...
  • Page 92 6278415.book Seite 92 Montag, 17. Oktober 2016 11:28 11 10 Storage and transport conditions Operating Instruction SIROSONIC/L/TL, PerioSonic Storage and transport conditions Dispatch Symbols Protect from Sensitive moisture contents 62 78 415 D3275.201.04.09.02...
  • Page 93 6278415.book Seite 93 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 10 Storage and transport conditions Relative Air pressure humidity Temperature After a severe change in temperature, allow sufficient time for acclimation. 62 78 415 D3275.201.04.09.02...
  • Page 94: Disposal

    6278415.book Seite 94 Montag, 17. Oktober 2016 11:28 11 11 Disposal Operating Instruction SIROSONIC/L/TL, PerioSonic Disposal ● According to current information, the product does not contain any substances that are hazardous to the environment. ● Disinfect the product prior to disposal. Disinfected ●...
  • Page 95 6278415.book Seite 95 Montag, 17. Oktober 2016 11:28 11 Operating Instruction SIROSONIC/L/TL, PerioSonic 11 Disposal 62 78 415 D3275.201.04.09.02...
  • Page 96 6278415.book Seite 96 Montag, 17. Oktober 2016 11:28 11 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK 0123 aPOTRKOMNKMQKMVKMO NMKOMNS ûKJkêKW=NOO=QPU páêçå~=aÉåí~ä=póëíÉãë=dãÄe páêçå~=aÉåí~ä=póëíÉãëI=ii` in USA:= c~Äêáâëíê~≈É=PN QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM aJSQSOR=_ÉåëÜÉáã `Ü~êäçííÉI=k`=OUOTP dÉêã~åó= SO=TU=QNR=aPOTR= ïïïKëáêçå~KÅçã= ïïïKëáêçå~KÅçã...

This manual is also suitable for:

PeriosonicSirosoni tl

Table of Contents