  • Page 1 VODN46xxIR IR Speed Dome Installation manual V1.0.0 Distributor: VOLTA Ltd Jutrzenki Street 94; 02-230 Warsaw www.volta.com.pl...
  • Page 2 IR Speed Dome Installation Manual This manual is furnished under license and may be used or copied only in accordance with the terms of such license. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by our company.
  • Page 3: Fcc Information

    IR Speed Dome Installation Manual Regulatory Information FCC Information compliance: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4 IR Speed Dome Installation Manual Safety Warnings and Cautions Please pay attention to the following warnings and cautions: Hazardous Voltage may be present: Special measures and precautions must be taken when using this device. Some potentials (voltages) on the device may present a hazard to the user. This device should only be used by employees from our company with knowledge and training in working with these types of devices that contain live circuits.
  • Page 5 IR Speed Dome Installation Manual use in your region. It must have certification marks showing certification by an agency in your region. The connector that plugs into the AC receptacle on the power supply must be an IEC 320, sheet C13, female connector. See the following website for more information http://kropla.com/electric2.htm.
  • Page 6: Safety Instruction

    IR Speed Dome Installation Manual Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. The precaution measure is divided into ‘Warnings’ and ‘Cautions’: Warnings: Serious injury or death may be caused if any of these warnings are neglected. Cautions: Injury or equipment damage may be caused if any of these cautions are neglected.
  • Page 7 IR Speed Dome Installation Manual Preparation for Installation Basic requirements. All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Check whether all the accessories are included according to the packing list. Make sure that the installation place and mode conform to the demands.
  • Page 8: Table Of Contents

    IR Speed Dome Installation Manual Table of Contents Chapter 1 Installation............................8 Installation and Cabling ............................8 1.1.1 Installing the Speed Dome ..........................8 1.1.2 Connecting the Cables ........................... 11 DIP Switch Settings ............................. 11 1.2.1 Address Settings ............................. 12 1.2.2 Baudrate Settings ............................
  • Page 9: Chapter 1 Installation

    IR Speed Dome Installation Manual Chapter 1 Installation Before you start: Check the package contents and make sure that the device in the package is in good condition and all the assembly parts are included. The adapter should be AC 24V/3A. Note: 1.1 Installation and Cabling 1.1.1 Installing the Speed Dome...
  • Page 10 IR Speed Dome Installation Manual Lock Screw Figure 1-2 Secure the Mounting Adapter 3) Tear off the protective sticker as shown in Figure 1-3. 4) Set the address, baudrate, protocol, etc. by switching the DIP switch in the speed dome. For the details about DIP switch settings, please refer to section 1.2 DIP Switch Settings.
  • Page 11 IR Speed Dome Installation Manual Grooves Hangers Safety Rope Figure 1-4 Install the Speed Dome 8) Use the allen key to tighten the lock screw on the mounting adapter for ensuring the speed dome is secured tightly. Lock Screw Figure 1-5 Secure the Speed Dome...
  • Page 12: Connecting The Cables

    IR Speed Dome Installation Manual 1.1.2 Connecting the Cables Before you start: Please make sure to cut off the power of the dome before connect the cables. The cable interfaces of speed dome are shown in Figure 1-6. Please refer to the following figure for the RS-485, power and video cables.
  • Page 13: Address Settings

    IR Speed Dome Installation Manual Figure 1-8 DIP Switch Figure 1-9 DIP Switch Label Notes: The default dome address is 0. The default baudrate is 2400, and the default status of the 120Ω terminator is OFF. The speed dome is self-adaptive to the Pelco-P, Pelco-D and Private-Code. You don’t have to set the RS-485 control protocol by the DIP switch.
  • Page 14 IR Speed Dome Installation Manual...
  • Page 15: Baudrate Settings

    IR Speed Dome Installation Manual 1.2.2 Baudrate Settings The number 7 and 8 DIP switches are used for setting the baudrate of the speed dome. The baudrate can be 2400bps, 4800bps and 9600bps. The baudrate will be set as 2400bps by default if it is out of this range.
  • Page 16 IR Speed Dome Installation Manual The cross-section of the cable is 1mm² and the transmission distance is less than 50m. According to the Appendix 3 Wire Gauge Standards, for example, the American wire gauge 18, the transmission distance should be 0.7854*50=39.27m.
  • Page 17: Chapter 2 Mount Dimension

    IR Speed Dome Installation Manual Chapter 2 Mount Dimension 2.1 Long Wall Mount Figure 2-1 Long Wall Mount Figure 2-2 Wall Mount Dimensions...
  • Page 18: Short Wall Mount

    IR Speed Dome Installation Manual Figure 2-3 Wall Mount with Power Supply Box 2.2 Short Wall Mount Figure 2-4 Short Wall Mount Figure 2-5 Short Wall Mount Dimensions...
  • Page 19: Corner Adapter

    IR Speed Dome Installation Manual 2.3 Corner Adapter Figure 2-6 Corner Mount 2.4 Pole Adapter Figure 2-7 Pole Mount...
  • Page 20: Chapter 3 Mounting Instructions

    IR Speed Dome Installation Manual Chapter 3 Mounting Instructions Before you start: For cement walls, expansion screws are needed for mounting (mounting in cement walls are taken as examples in blow sections). For wooden walls, you need to use self-tapping screws. Please make sure that the wall is sturdy enough to withstand more than 8 times the weight of the dome and the bracket.
  • Page 21: Mounting With A Long Mount

    IR Speed Dome Installation Manual 3.1.2 Mounting with a Long Mount Steps: 1. Drill four holes in the wall. Insert M6 expansion screws (not supplied) into the mounting holes. Figure 3-3 Drill the Holes in the Cement Wall 2. To secure the wall mount, screw hex nuts padded with flat washers through the wall mount and the rubber gaskets to the expansion screws.
  • Page 22: Mounting With A Power Supply Box

    IR Speed Dome Installation Manual Figure 3-5 Finish the Installation 3.1.3 Mounting with a Power Supply Box Steps: 1. Drill four holes in the wall. Insert M10 expansion screws (not supplied) into the mounting holes. 2. To secure the power supply box, screw hex nuts padded with flat washers through the power supply box and the rubber gaskets to the expansion screws.
  • Page 23: Corner Mounting

    IR Speed Dome Installation Manual Figure 3-7 Install the Mount 4. Install the dome to the mount Please refer to Chapter 1 for dome installation. Figure 3-8 Finish the Installation 3.2 Corner Mounting Corner mounting is applicable to indoor/outdoor 90°corner constructions. Note:...
  • Page 24: Components

    IR Speed Dome Installation Manual 3.1.1 Components Mounts A corner mount has to be used together with a wall mount for corner mounting applications. Figure 3-9 Corner Mount Figure 3-10 Corner Mount and Wall Mount Mounting Accessories Figure 3-11 Hexagonal Screws (M8×30), Nuts, Spring Washers and Flat Washers...
  • Page 25: Corner Mounting Instructions

    IR Speed Dome Installation Manual 3.1.2 Corner Mounting Instructions Steps: 1. Drill four holes in the corner. Insert M6 expansion screws (not supplied) into the holes. 2. Pass the power cord, video cable and control cable through the opening of the corner adapter. Make sure the cables are long enough.
  • Page 26: Pole Mounting Applications

    IR Speed Dome Installation Manual Figure 3-13 Install the Wall Mount 5. Install the dome to the mount Please refer to Chapter 1 for dome installation. Figure 3-14 Finish the Installation 3.3 Pole Mounting Applications Pole mounting is applicable to the indoor/outdoor pole constructions Note:...
  • Page 27: Mounting Components

    IR Speed Dome Installation Manual 3.1.3 Mounting Components Mounts A pole mount has to be used together with a wall mount for pole mounting applications. Figure 3-15 Pole Mount Figure 3-16 Wall Mount Pole Mounting Hoop Pole mounting hoop is used for pole mounting with pole mount and wall mount. There are following dimensions selectable: φ59-82mm, φ84-108mm, φ103-127mm, φ130-152mm, φ155-178mm, φ180-203mm and φ194-216mm.
  • Page 28: Pole Mounting Instructions

    IR Speed Dome Installation Manual Figure 3-17 Pole Mounting Hoops Mounting Accessories Figure 3-18 Hexagonal Screws (M8×30) and Spring Washers 3.1.4 Pole Mounting Instructions Steps: 1. To assemble pole mount and pole mounting hoops, loosen the hoops with a screw driver and insert them through the holes of the mount.
  • Page 29 IR Speed Dome Installation Manual Figure 3-19 Assemble the Hoops and the Pole Mount 2. Pass the power cord, video cable and control line through the opening of the pole mount. Note: Make sure the cables are long enough. For outdoor applications, you can use sealant to seal the cable openings for waterproofing.
  • Page 30 IR Speed Dome Installation Manual tighten them to the pole mount. Figure 3-21 Install the Wall Mount 6. Install the dome to the mount Please refer to Chapter 1 for dome installation. Figure 3-22 Finish the Installation...
  • Page 31: Appendix 1 Lightning And Power Surge Protection

    IR Speed Dome Installation Manual Appendix 1 Lightning and Power Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W (Eg, Lightning , power surges and etc.) Necessary protections must be taken to secure the electrical safety outdoors.
  • Page 32 IR Speed Dome Installation Manual Figure A. 1 Lightning Protection and Grounding...
  • Page 33: Appendix 2 Rs485 Bus Connection

    IR Speed Dome Installation Manual Appendix 2 RS485 Bus Connection 1. RS485 Bus Properties RS485 is a half-duplex communication bus which has 120Ω characteristic impedance, and its maximum load ability is 32 payloads (including controlling devices and controlled devices). 2. RS485 Bus Transmission Distance Using 0.56mm (24AWG) twisted-pair line, the max transmission distances for different baud rates are shown as below: Baud Rate...
  • Page 34 IR Speed Dome Installation Manual The 120Ω terminal resistors can be connected through the DIP switch on the circuit board and default as disconnected. To connect the resistor, simply switch on the eighth position of SW2. Please refer to section 1.3 for more about DIP switch settings. 5.
  • Page 35 IR Speed Dome Installation Manual Table A.2 RS485 Bus FAQs and Solutions...
  • Page 36: Appendix 3 Wire Gauge Standards

    IR Speed Dome Installation Manual Appendix 3 Wire Gauge Standards Table A.3 Wire Gauge Standards...