8200 Rubidium Oscillator
User's Guide
17 December 2009, Rev. A
Part Number: 098-00071-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 098-00071-000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Symmetricom 098-00071-000

  • Page 1 8200 Rubidium Oscillator User’s Guide 17 December 2009, Rev. A Part Number: 098-00071-000...
  • Page 2: Symmetricom Customer Assistance

    Symmetricom Customer Assistance To find the Symmetricom representative closest to your location, please visit Symmetricom World- wide Sales http://www.symmetricom.com/Contact/Sales online. To reach a Symmetricom Customer Assistance Center, call one of the following numbers: Worldwide Main Number: 1-408-428-7907 US Toll-free Number: 1-888-367-7966 (1-888-FOR-SYMM) Europe, Middle East &...
  • Page 3: Notices

    Symmetricom’s factory freight prepaid; provided, however that Buyer has first obtained a return materials authorization number ("RMA Number") from Symmetricom authorizing such return. The RMA Number shall be placed on the exterior packaging of all returns. Symmetricom will pay ship- ping costs to return repaired or replacement goods to Buyer.
  • Page 4: Contact Information

    Symmetricom, Inc. Timing, Test & Measurement 3750 Westwind Blvd. Santa Rosa, CA 95403 Main: +1 (707) 528-1230 For Sales, Technical Support, and Return Materials Authorization, please see Symmetricom Cus- tomer Assistance (see " Symmetricom Customer Assistance" on page 2). 4 of 25...
  • Page 5: Table Of Contents

    Table of Contents Table of Contents Symmetricom Customer Assistance Notices Copyright Limited Product Warranty Limitation of Liability Contact Information Table of Contents 1. How to Use This Guide Purpose of This Guide Who Should Read This Guide Guide Structure Conventions 2.
  • Page 6 Contact Information 8200 RF Outputs 5. Installation and Operation Installation 8200 Start-up Sequence 6. Symmetricom Serial Interface Protocol Using the Symmetricom Serial Interface Protocol Data Format Adjust Frequency (commands f and t) Factory Mode Index 6 of 25...
  • Page 7 Table of Contents This page intentionally left blank 7 of 25...
  • Page 8: How To Use This Guide

    8200 oscillator, including a simplified theory of operation, maintenance and warranty. " 6. Symmetricom Serial Interface Protocol" on page 22 - This section describes how to use of the external communications link software. 8 of 25...
  • Page 9: Conventions

     1. How to Use This Guide Conventions Note: Notes contain installation, operation, or maintenance procedures, practices, conditions, or statements that alert you to important information, which may make your task easier or increase your understanding. Warning: To avoid serious personal injury or death, do not disregard warnings. Warnings are instal- lation, operation, or maintenance procedures, practices, or statements, that if not strictly observed, may result in serious personal injury or even death.
  • Page 10: Product Description

    The protocol used is Symmetricom's proprietary Symmetricom Serial Interface Protocol (see " 6. Sym- metricom Serial Interface Protocol" on page 22), or SSIP.
  • Page 11: 8200 Standard Oscillator

     2. Product Description Figure 2.1 Simplified Block Diagram 8200 Standard Oscillator The standard performance 8200 oscillator provides a 10MHz sine-wave output along with a 15 pin con- nector for monitoring and controlling the module. The core component in this module is based on Sym- metricom's X72 rubidium oscillator.
  • Page 12: Specifications

    3. Specifications Environmental Requirements Temperature: Operating: -40º C to +80 º C base-plate Standard 8200 Storage: -55º C to +95º C Sensitivity: <3.0E-10 over op. temp. range Thermal shock (non-operating): MIL-STD-202, Method 107, Test Condition A, 10 cycles -55° C to 85º C Orientation sensitivity: <5.0E for any orientation...
  • Page 13: Dimensions - 8200

     3. Specifications Vibration: MIL-STD-810, Method 514.5, Procedure I Operating: Category 24, Minimum Integrity, 7.7 grms @ 0.04 g /Hz 20 Hz -1kHz, 15 min/axis (maintain lock) Non-operating: Category 24, Minimum Integrity, 15.4 grms @ 0.16 g /Hz 20 Hz -1kHz, 30 min/axis Shock: MIL-STD-202, Method 213 Operating: 30g, 11msec, half-sine (maintain lock)
  • Page 14: Electrical Specifications

    Electrical Specifications Electrical Specifications - 8200 Characteristics All limits are given at base-plate temperature of 25°C, and Supply Voltage of 25VDC unless noted otherwise. Description Conditions Units Supply Voltage Frequency Accuracy at shipment -5*10 5*10 Power consumption during warm-up Warm up time to lock @ -40°C base-plate Mins @ 25°C base-plate...
  • Page 15  3. Specifications This page intentionally left blank 15 of 25...
  • Page 16: Design Integration Considerations

     Mechanical Drawings - 8200 4. Design Integration Considerations This section provides information on mounting, mating connectors, operating temperature, electrical interface, EMI, and noise susceptibility. Mechanical Drawings - 8200 Figure 4-1: Isometric View Figure 4-2: Dimensions Side Bottom 16 of 25...
  • Page 17: Mechanical Considerations

    In order to achieve the highest ambient operating temperature for the oscillator operating base plate temperature, Symmetricom recommends that the bottom ("base plate") of the oscillator has good ther- mal contact to the mounting surface. It is also very important to maintain a uniform temperature into the base plate of the 8200 through its mounting points.
  • Page 18: External Interfaces And Grounding

     External Interfaces and Grounding As the base plate temperature continues to increase, the unit eventually loses lock. Above a base plate temperature of +80° C, the resonator, or lamp heaters shut down as control point temperatures are exceeded, and the unit temperature coefficients increase to approximately 6xE °...
  • Page 19: Connector J1 Signals

     4. Design Integration Considerations Connector J1 Signals Pin# Signal Name Type Signal Function + Power input +15 to +32 Vdc - all power pins must be 1, 2 PWR In connected. D_OUT Output UART data out at ACMOS logic levels. 4, 5 - Power &...
  • Page 20: Installation And Operation

    To monitor performance and selectively modify it using the SSIP firmware included in the unit, connect the unit to the COM port of a PCvia Developer’s Kit cable and adapter (Symmetricom P/N 054-00269-000). 20 of 25...
  • Page 21  5. Installation and Operation This page intentionally left blank 21 of 25...
  • Page 22: Symmetricom Serial Interface Protocol

    1 stop bit No local echo (unit echoes) No hardware or software flow control Note: The 8200's UART connections are based on 5 Vdc logic levels. RS232 Adapter (Symmetricom p/n 054-00269-000) required to connect 8200 to PC. Data Format Run Mode Data Format (Customer Mode) 8200 outputs are all decimal data as “ASCII Coded Hex”...
  • Page 23: Adjust Frequency (Commands F And T)

     6. Symmetricom Serial Interface Protocol Mode CN1B Flag 0005 Unit serial code is 0311BB0198-h, current tuning state is 6 Crystal: 3938700hz, ACMOS: 989680.00000000hz, Sine: 989680.00000000hz Ctl Reg: 0204, Res temp off: BFC53F7D., Lamp temp off: C003B7E9. FC: disabled, Srvc: low r>...
  • Page 24: Index

     Factory Mode Index 8200 Connectors 8200 RF Outputs 8200 Standard Oscillator Conventions Design Integration Considerations 8, 16 Dimension - 8200 Electrical Specifications Electrical Specifications - 8200 Environmental Requirements External Interfaces and Grounding Factory Mode Guide Structure How to Use This Guide Installation Installation and Operation 8, 20...
  • Page 25 Purpose of This Guide Specifications Start-up Sequence Symmetricom Customer Assistance 2, 4 Symmetricom Serial Interface Protocol 8, 10, 22 The 8200 Line of Rubidium Oscillators Thermal Considerations Using the Symmetricom Serial Interface Protocol Who Should Read This Guide 25 of 25...