Download Print this page

Troubleshooting And Specifications; Technical Specifications - Carlton DH14L Manual

Advertisement

Troubleshooting & specifications
TROUBLE SHOOTING
BEFORE CONTACTING THE MANUFACTURER
OR HIS AGENT, PLEASE CHECK THE FOLLOWING
POSSIBILITIES.
PROBLEM
POSSIBLE CAUSE
Unit fails to
1. Power
off
2. Power cord
unplugged
operate
3. Water tank not fitted correctly
4. Water tank is
full
5. Defrosting
1. Blocked air filter
Performance
2. Room windows and doors open
decreased
3. Obstacles in air outlet or air inlet
1. Unstable setting of unit
Unit noisy
2. Blocked filter
........................................................................
CORRECTIVE ACTION
Switch power
on
Restore power cord
Re-position water tank
Empty water tank
After defrosting, the unit will
dehumidifying again.
Wash nylon filter
Close room windows and doors
Remove obstacles
Reposition unit
Wash nylon filter
........................................................................

TECHNICAL SPECIFICATIONS

Model
DH14L
Dehumidifying capacity
14L/d
230 - 240V~ 50Hz
Power supply
Current
1.1A
Power consumption
220W
5~35 C
Working Environment
25% RH and above
Water tank volume
4L
20kg
Net weight
H620 W280 D320mm
Dimension
Capacity will vary according to actual room
temperature and humidity conditions.

Advertisement