Room panel

Advertisement

Quick Links

ZAKŁAD PRODUKCJI URZĄDZEŃ ELEKTRONICZNYCH „ELSTER" Sp.J.
fax: +48 61 43 67 690
USER'S MANUAL FOR ASSEMBLY AND HANDLING
The room panel ROOMSTER was designed for cooperation with the
Expert PID Dynamic 4D regulators and chosen models of Luksus EKO PID
Dynamic regulators. It has a house temperature week program with the
exact measurement of the room temperature from 0,1
built-in communication with the boiler the device displays information
about emergencies and measured temperatures. The panel has its' own
memory for the user's settings and in case of cooperation with the Expert
regulator it automatically synchronizes the actual timing from the boiler
controller, without having to adjust it manually.
I. Preparation for work.
The room panel ROOMSTER RTx connects wirelessly with the boiler
temperature regulator through radio communication module attached to
the regulator. The radio communication module and the room panel com-
municate on the selected frequency channel. The default settings indicate
operation on the 0 channel. When in the room there are more than 1 room
panels operation, each of the module-panel pairs must communicate on
different frequency channel. In such case there is a necessity to change the
default settings.
1. Preparation of the communication module RTX.
When the boiler temperature regulator, either Expert or Luksus, is in
the built-in version, the communication module must be connected to the
regulator through putting the XLR plug to the appropriate socket in the
sensor panel on the boiler. In other cases the connection must be made
through connecting three-wire cable coming out of the module to the regu-
lator terminal or valve intended for connect the panel:
Obłaczkowo 150, 62-300 Września, Polska
www.elster.w.com.pl
ROOM PANEL
ROOMSTER II RTx
Yellow
color
Version 1
brown
1
white
2
green
AUX +5V
Terminal designations:
Version 2
Br
Bi
AUX +5V
mail: elster@post.pl
tel.: +48 61 43 77 690
o
C. Thanks to the

Advertisement

loading

Summary of Contents for Elster ROOMSTER II RTx

  • Page 1 ZAKŁAD PRODUKCJI URZĄDZEŃ ELEKTRONICZNYCH „ELSTER” Sp.J. Obłaczkowo 150, 62-300 Września, Polska www.elster.w.com.pl mail: elster@post.pl tel.: +48 61 43 77 690 fax: +48 61 43 67 690 ROOM PANEL ROOMSTER II RTx USER’S MANUAL FOR ASSEMBLY AND HANDLING The room panel ROOMSTER was designed for cooperation with the Expert PID Dynamic 4D regulators and chosen models of Luksus EKO PID Dynamic regulators.
  • Page 2 If there is a necessity to change the channel, one must: • Disconnect the module from the regulator ort urn the power off, • Using a head screwdriver unscrew two screws placed in te back of the module housing. • Take the housing off.
  • Page 3 • A writing CH and the actual channel number will be displayed on the screen, • Using the buttons set the new channel number, • Confirm the changes by the button – one will be redirected to the main screen II.
  • Page 4 • active program through all day; the black fields mean the active day temperature; • active when the screen displays the actual temperature from the weather sensor; • active when the screen displays actual temperature of the boiler shell; • active when the screen displays actual temperature of the valve sensor;...
  • Page 5 The actual set temperature changes in accordance with the set pro- gram, in pursuance of the actual time given by the built-in watch and the temperature set for a given time: day/comfortable or night/lowered. When the temperature program is turned off [OFF] the set tempera- ture for the room is the day/comfortable temperature.
  • Page 6 or [OFF] – turn off the program mode How to set: • Using the buttons choose the program number (1,2,3) or turn the program off (OFF); the chosen program is marked by a blinking frame; • If one wants to set the program in the next point, he should – using the button –...
  • Page 7 • Aftr midnight the day will be changed automatically (or group of days in program 2) • Touch the button – the user will be moved to the point 3 3. Setting the day/comfortable temperature. The screen looks as follows: °C The icon .
  • Page 8: Additional Information

    How to set: • Using the buttons set the wanted temperature in increments of 0,1 °C • Touch the button – the user will be moved to the point 5 5. Setting the actual time. The screen looks as follows: When the room panel is connected to the controlling valve module through the Expert regulator, the actual time is synchronized automatically with the regulator and the possibility to set in in the panel is blocked.
  • Page 9 The information availability depends on the correctness of communi- cations with the valve module or the controller. After the first pushing of the button the screen will display a set of icons, dependent o the controller the panel cooperates with.. For the Luksus controller: For the Expert controller: A type of displayed valve is signalized by blinking of an appropriate...
  • Page 10: Device Installation

    • and text Means other alarm from the boiler’s regulator °C - - . - • (no value) means damage of the room panel. VII. Technical data. Internal powering: 2 AA 1,5V batteries Environment temperature: 0..55°C Storage temperature: 0..55°C Relative humidity: max 77% Measurement range: 0..55°C...