Multiple Alarms; Ncvt2 Control Unit Front Panel (C132) - Nuomm NEWSCASTER VT2 User Manual

Eng/ob microwave transmitter
Table of Contents

Advertisement

NewsCaster VT2

5.5.1 Multiple Alarms

Under some situations, multiple alarms may occur. If this happens, correct any power supply
voltage problem first. In many instances, other alarms will be triggered as the result of a missing or
out of range power supply level.

5.5.2 NCVT2 Control Unit Front Panel (C132)

When a problem occurs without an alarm prompt, a good starting point is to check all of the setup
menus. A parameter may have been inadvertently missed or set to the wrong value. If that doesn't
solve the problem, then make a check of all internal cabling of the NCVT2 Control Unit, ensuing
that all cables are properly seated and fastened tightly (if applicable). Also check to see if all
jumpers (if any) have been installed properly. Finally, check all power supply voltages of the
Control Unit, ensuring that they are within their specified limits.
To minimize the possibility of Electro-Static Discharge (ESD) damage, ensure that all
equipment is properly grounded and that you are using ESD protective practices and
equipment!
NOTE: With COAX / TNC cables, the +45 VDC is on the center pin of the cable. For TRIAX
cables, the +45 VDC is carried on the inner shield instead.
M17-0002-01A Rev 0.0
WARNING!!!
69
Operation
User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents